(Category: 1800)
new
Carbolite Gero AX30 Heating Oven Original price 3385 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 918 Holding power (W) 342 Weight (kg) 24 Condition: new, without original packaging ...
new
Carbolite Gero AX30 Heating Oven Original price 3185 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 1000 Holding powe ...
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm Buy incubators and other products at low pric ...
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm More items new and used - you can find them ...
used
GE Äkta Explorer FPLC 100 Air/General Electric/Cytiva -Box 900 -pH/C 900 monitor -UV 900 UV Detector -UV Flow Cell -P 900 Pump /100ml/min w. Switch Valves Air 900 Control Box -pH Sample -Conductivity Cell -INV 907 Injection V1 Sample Valve V5 Outlet Valve V4 Column Valve V2 Column Valve V 3 -P 960 -M 925 MIxer (2ml) on request 5 and 12 ml) FR 902 Restrictor CU-950 Interface Unicorn Software -Frac 950 Faction Collector warranty
used
Carbolite CWF 11/5 Chamber Furnace 1100 °C Max Temp: 1100 °C With suction device and table The upward-opening door keeps the hot surface away from the user Gently self-closing door (for 5, 13, 21 & 23 litre models) Standard start-up delay and process timer function Durable alumina backing plates for the heating elements; Robust door frame and base plate High-quality fiber insulation with low thermal mass Powerful heating elements on both sides ensure very good temperature homogeneity Easy access to elements and controls simplify maintenance and servicing More items new and used - you can find them in our shop! International shipping costs on request!
used
Hitachi HPLC System LaChrom Elite -Power Box -L 2130 Gradient Pump -L 2300 Column Thermostat -L 2200 Autosampler (cooling) -L2455 DAD Diode Array Detector
used
Agilent G 1362 A RID Detector Refractive Index Range 1.00-1.75 RIU Measurement Range +/- 600x 10-6 RIU Sample Cell 8 ul Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN
used
Agilent G 1321A Fluorescence Detector Ex Monochromator range 200 – 700 nm Em Monochromator range 280-900 nm Wavelength characteric Repeatability +/- 0.2 nm Accurcacy +/- 3 nm Flow cell 8μl Analog Output/Recorder/Integrator 100mV or 1 V Communications: CAN, GP-IB, RS 232; LAN Remote: ready, start, stop and shut down signals
used
Agilent 5973 N MSD Detector with Edwards turbomolecular pump or diffusion pump, used and refurbished on request also complete as measuring station with Agilent 6890GC Please inquire about the price per piece
used
GE Äkta Purifier 10 FPLC System Box 900 P 900 Pump /10 ml pump heads UPC 900 Monitor INV 907 Valve M925 Mixer / 6 ml mixing chamber Conductivity Flow Cell pH Sample CU 950 Interface/Communication Module FRAC 920 Fraction Collector Unicorn Software
used
Agilent 5973N inert MSD with GC Agilent 6890 N Agilent 5973 N inert MSD with GC Agilent 6890 N Network Agilent 5973 inert MSD with EI and turbomolecular pump enhanced BOC Edwards Turbopump Agilent GC 6890 Network with Split/Splitless Injector/EPC Edwards Vacuum Pump 1.5 MSD Productivity Chemstation E02.02 on PC/Win 10 NIST on request Option: Agilent Liquid Sampler, CTC or Gerstel MPS2 Sampler currently serviced/with warranty Installation on request
used
Agilent 5973 MSD Detector,Network/LAN Connector, Diffusion pump, completely overhauled
used
Perkin Elmer PinAAcle 900 F Flame AAS Perkin Elmer AAS PinAACle 900F F Flame AAS True double beam, 8 –lamp mount, Fibre Optic light path automated flame and burner optimization PC and Perkin Elmer WinLab Software Lamps on request Last Service 07/2022 with warranty
used
Waters Acquity UPLC-MS System, Used Acquity UPLC-MS System by Waters from 2009, used very little, with systematic proof of maintenance, from a large pharmaceutical company, with 6 months warranty and training and installation at the customer's site. . The system is sold with an additional set of spare parts in the form of an identical UPLC system (without MS). Each system can be viewed and tested in operation. The UPLC-MS system consists of the following parts: - SQD mass detector - Sample Organizer - Sample Manager - PDA detector - Binary Pump Manager - Column Manager Price complete system with additional modules as spare parts
used
Perkin Elmer Lambda 25 UV VIS Spectrophotometer, Dual-beam device, wavelength range 190-1100nm, 10 mm or 100mm cuvette holder, Option flow-through cuvette with peristaltic pump, Software Perkin Elmer WinLab
used
Dionex ICS 90 Ion Chromatograph, Ion chromatograph with conductivity measuring cell, Suppressor technology, Pump: Flow rate 0.5 – 4.5 mL/min Detector range: 0-500 μS or 0-10 000 μS (selectable) DS 55 Detection stabilizer, Ion Pac AG 23/4 x 50 mm Gurad, Dionex 4 x 250 mm Analytical Connectors: USB and TTL
used
Beckman Proteomelab PF 2D Protein Fractionation, Integrated Protein Fractionation System 1. Dimension collecting protein fractions based on pH of the mobile phase 2. Dimension Reverse phase separation of the fractions Hardware: -Injector -pH monitor -UV detector -fraction collector 2. Dimension Fraction Collector -HPRP module, high performance reversed phase module -column heater -UV detector Software
used
Gerstel / CTC Mutlti Purpose Sampler MPS complete For the LC as well as GC YOC 2014, tray for 98 vials (2ml), gas-tight injection syringes
used
BMG Polarstar Optima and Fluostar Optima Multimode Microplate Reader Up to 384 wells Fliter wheel 8 Excitation Filter wheel 8 emission Fluorescence intesity -time resolved fluorescence -Absorbance and luminicence POLASRSTAR Fluorescense polarization mode linear and orbital shaking Fluorescence 240-740 nm Absorbance 240-740 nm Fluorescence polarization 380-740 nm Additional 12 more filters
used
Agilent 1200 HPLC system consisting of: Agilent 1200 G 1312B SL binary HPLC pump (up to 600 bar) Agilent 1200 G 1315B Diode Array Detector Agilent 1200 G 1316 B TLC SL Colcom/column thermostat Agilent 1200 G 1379 Degasser Agilent 1200 G 1330 Thermostat for Autosampler Agilent 1200 G 1367D Autosampler Hip ALS SL + on request with Agilent Chemstation/Warranty
used
Hitachi LaChrom L 7485 Fluorescence Detector Excitation 200-850 nm Emission 250-900 nm Autozero analytical flow cell
used
Siemens X-ray tubes Type Megalix Cat 125 / 35 / 80 - 121 GW Siemens article number 05764606 Type Megalix Cat 125 / 15 / 40 / 80 - 121 GW Siemens article number 05764522
C - elbow, type Ziehm Vision R in very good technical and optical condition.
used
BDK S-1200 Laminar-Flow Safety Cabinet Principle The safety cabinet is a laboratory device in which there is a largely low-turbulence (laminar) displacement flow in the working area. The air flowing through the working area, as well as the exhaust air, is cleaned by a high-performance HEPA filter. Scope of services and equipment - Model version The safety cabinet is produced in three different sizes, as BDK-S 1200, 1500 and 1800. - Air monitoring The air flow velocity in the circulating air (downflow working area) and exhaust air (inflow exhaust air) area is monitored with flow probes. Any faults that occur are indicated by an indicator light and signal horn. - Lens monitoring The viewing window made of safety laminated glass is provided with a weight compensation system and can be moved manually very smoothly and continuously. If the lens is not in the working ...
used
BV 17 cm, LIH, CRT double monitor, patient archive system
used
Haemonetics ACP 215 Automated Cell Processor. The ACP 215 Automated Cell Processor is the world's first and only automated, closed-loop red blood cell processing system. It minimizes the risk of bacterial contamination and provides donor centers and hospitals with the security and flexibility they need. Whether your facility is washing red blood cells, stockpiling rare blood supplies, or building a complete strategic blood bank program, Haemonetics is here to help you every step of the way to execute your entire plan.
C - Arc X-ray machine - Year of construction 2014 - possibly with video printer - DICOM prepared
used
Sartorius Stedim biotech BioWelder 16370 The BioWelder works with a thermal welding cycle that does not require laminar flow. In this welding process, the blade is kept sterile and endotoxin-free throughout the process. The inserted hoses are cut with a knife and then fused together by the device. The cycle process is fully automated and is only released after a full cycle. Various programmable holders make it possible to weld thermoplastic hoses of the same type (e.g. C-Flex, Sanipure, Pharmed) with diameters from 6.4 mm (1/4") to 19.0 mm (3/4"). Characteristics: Fully automatic operation Welds thermoplastic tubes up to 3/4 inch outer diameter Pre-installed settings for C-Flex, Raumedic FluiSoftTM, AdvantaPure, AdvantaFlex, Pharmed and Sanipure hoses True Thermal Weld offers exceptional strength Aseptic connection without laminar flow hood Data output by a print ...