We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1800)
used
Agilent 7890A +5975C+7683(100 tray) with SSL + PTV inlet. And with pump. Agilent 7890A +5975C+7693(150 tray) with SSL + PTV inlet. And with pump. Both in very good condition.
used
1. PE 200 AAS, tipo a fiamma.(con schermo di controllo, potrebbe funzionare senza o con computer) 2. PE 400 AAS.(senza schermo di controllo) 3. PE 900Z, tipo grafite. Tutti in ottime condizioni e set completo di computer e accessori necessari.
used
Agilent GC 6890N, Detector WLD Option: Extension with FID Injector: Split/Splitless with EPC LAN connection Agilent Chemstation B04.03
used
Metrohm 848 Titrino plus Titrator Dynamic Titrations (DET) with automat. Equivalence point Montone Titration (MET) with automat. Equivalence point Endpoint Titartion (SET) Red-Ox titare ions (e.g. iodometry, permanganometry, etc.) Complexometric titrations Titarions with pol. Electrodes (I pol.; Upol) etc.
used
Anton Paar DM 4500 Density Measuring Device Option: RXA 170 refractometer Density determination measuring range 0.6-2g/cm3 Temperature range 5-70 Celsius Sample quantity 1 ml Price without RXA 170
used
Espec PR-3KP Climatic Test Chamber -20 to +100 °C Characteristics: Manufacturer: Espec Type: PR-3KP Temperature range: -20 to +100 °C Humidity: 20 to 98% RH Refrigerant R-404A:- CFC-free – ozone-friendly Hours: 56530 Metrics: External dimensions: HxWxD= 1680 x 1050 x 1200 mm Chamber dimensions: HxWxD= 850 x 600 x 800 mm More items in other sizes - new and used - can be found in our shop! International shipping costs on request!
C - Bow, Type Ziehm Vison Solo Very good technical and optical condition
Siemens Somatom Definition Flash, 128 lines, built in 2011, 2 X-ray emitters Straton MX ( DoM 2021 440.000 SS / DoM 2022 installation 2023 87000 SS )
used
Metrohm 904 Titrando with 815 XL Sample Processor Metrohm 904 Titrando with 20 ml burette and 815 robotic sample Processor and 805 Dosimat High End Titrator Potentiometric Titrator, Dynam. (DET) Endpoint titration ,monotonous (MET) Titration.Ion Selective Electrode
used
For sale is a used, well-preserved Infusomat P from B.BRAUN with drop sensor, power cord and device holder. valid MTK 9/24
used
Zeiss Intrabeam System Irradiation Device, Accelerator. Used in ophthalmic therapy, tumor irradiation. With PTW dosing device. Complete with instruction manual, samples, etc.
used
GE/Amersham Äkta Pilot prep. FPLC; Software Unicorn 5.2, further information on request
used
Agilent 5975C inert MSD with GC 6890N Agilent 5975 C inert MSD, Agilent GC 6890 N Pfeiffer Turbomolecular Pump, Electronic Ionization/EI ; GC Injector Split/splitless, EPC, LAN Agilent Backing Pump, Software Agilent MSD Chemstation for Win10
used
Perkin Elmer HS 40, Headspace sampler for 40 vials, max. temperature + 210 Celsius, min. +35 Celsius, fits all gas chromator graphs,
used
Siemens swivel arm / U-arm X-ray imaging workstation with the following system components: Alternator Polydoros LX 30/50, Tube Opti 150/30/50 HC 1x detector Protec Rapixx 4343 M2i Workstation Patient couch • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning and configuration of the system or ...
used
Used Tecan Freedome evo 200 pipetting robot with TE-MO 3/5 Pictures will follow
used
Used pipetting robot Tecan EVO 150 with Tecan dongle and CDs and accessories .
used
Rofin StarCut Tube Fiber Stent Cutting System Used Year of construction : 2012 Lasers For cutting almost all metal alloys and plastic compounds commonly used in medical technology. Pictures will follow !
used
Used Thinking Super Cascom Dental Die Casting Machine Year of manufacture : 2014 Think compressor ! Year of construction : 2015
used
Nova BioProfile Flex Automated Cell Culture Analyzer BioProfile is an automated cell culture analyzer that measures up to 15 important cell culture attributes. By combining up to five separate instruments into one easy-to-use instrument, BioProfile FLEX simplifies workflow and saves time, labor, and operating costs compared to multiple instruments. The FLEX automatic sampler takes samples from its two fermenters and transmits them to the measuring unit of the FLEX analyzer. The data obtained from the FLEX autosampler were compared with data taken manually from the reactor and their statistical analysis was performed. Specifications Sample analysis time: 2.5 minutes (gases only – PO 2 + PCO 2 ), 4.0 minutes (Chemistry/Gas and Osmolality), 6.25 minutes (all 15 tests), Operating temperature range: 15-30 °C (59-86 °F), Relative operating temperature Humidity range: 20-85 ...
used
AGFA Imaging Plate System / CR System CR 30-X (for Veterinarian) Primary processing station 3 CR cassettes • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning and configuration of the system or system components must be carried out by the manufacturer or by a specialist or technician authorized b ...
used
Siemens combined X-ray recording and fluoroscopy device Iconos R 200 with the following system components: Generator Polydoros SX 65 Tube Optitop 150/40/80 HC 0,6/1,0 Digital image processing Fluorospot Compact Sirecon 33-4 HDR image intensifier • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • The installation, commissioning and configuration of the system or system components must be carried out by the manufactur ...
used
AGFA / Siemens X-ray imaging workstation DX-D 500 (digital) with the following system components: Generator Siemens Polydoros IT 80 Tube Siemens SV 150/40/80 HC 0.6/1.0_Bj. 2018 Vertical tripod Siemens Vertix T Fa. Siemens 2x detector VARIAN 4343R CSi_43x43cm Workstation • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • T ...
used
AGFA / Siemens X-ray recorder DX-D 500 (digital) with the following system components: Generator Siemens Polydoros IT 80 Tube Siemens SV 150/40/80 HC 0.6/1.0 Vertical tripod Siemens Vertix T 2x detector VARIAN 4343R CSi_43x43cm Workstation • Before taking over, all devices and systems have been tested on site for their functionality. • The system is located in our warehouse in Freiberg / Germany. It is packed on pallets, professionally lashed and wrapped with stretch film and can be picked up immediately • You buy the system in the "AS" condition from the warehouse Freiberg (EXW), Saxony, Germany, and pay in advance. • Sold as "Used", EXW Freiberg, Saxony, Germany, to resellers or dealers despite full functionality without warranty. • To restart the device, you will most likely need a license from the device manufacturer. • The installation, commissioning ...
new
Carbolite Gero AX30 Heating Oven Original price 3385 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 918 Holding power (W) 342 Weight (kg) 24 Condition: new, without original packaging ...
new
Carbolite Gero AX30 Heating Oven Original price 3185 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 1000 Holding powe ...
Siemens X-ray system type Multix Select DR Very good technical and optical condition
Siemens X-ray system type Multix TOP with Vertix TOP with 3D3 ceiling suspension Very good technical and optical condition
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm Buy incubators and other products at low pric ...
used
mytron 160 K CO2 Double Incubator The CO2 Incubator 160 / 160K provides the "in vitro" growing cell and tissue cultures with environmental conditions that are very close to the physiological values of the organism. Interior volume: approx. 160 l Weight: 70 kg Recirculating air circulation: by fan Cooling: Cooling unit Temperature display: Setpoint and actual value display Temperature range: 5 °C above room temperature to 70 °C Temperature range (cooled): +15°C to 70°C at 23°C ambient Temperature constancy: +/- 0.2 K temporal Humidity display: setpoint and actual value display Humidity range: >/=95 % Moisture resistance: +/- 2.5 % CO2 display: setpoint and actual value display CO2 range: 0% to 20% CO2 CO2 constancy: +/- 0.2 % CO2 CO2 recovery time: 1% CO2/min Power supply: 230 V, 50 Hz, 2 x 8 AT WxHxD= 130x85x70 cm More items new and used - you can find them ...