Francis turbine, used 40 kW, 3 m³, height 2m Speed 106 / 375 RPM 69 HP, built in 1963 Generator Schorch GmbH Type KT 7315 s FB01 Z-Z 50 Hz, 512U/min 55kW
used
Kaplan turbine used 50 kW, 3 m³, height 2m Speed 150 / 460 RPM 70 HP, built in 1963 Generator Schorch GmbH Type KT7280S - DB05 Z-Z 50 Hz, 770 RPM 55kW
used
HHI-BBC Turbine Housing RPM - 17400 Only the turbine hull.
used
2x Tapping back-pressure turbine with spur gearbox and generator Nr1: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 3800 kW Speed: l0000 rpm Steam inlet pressure max. : 37 Steam inlet temperature max. 44 degrees Tapping pressure max. : 24 Tapping temperature : 390 degrees Evaporation pressure : 2 Normal absorption capacity : 27 t/h Maximum absorption capacity : 32 t/h Gearbox Make Voith, St.Pölten Type D 64 Rated power: 5,700 HP Speed 10 OOO/1 5oo rpm Backpressure steam turbine + gearbox + synchronous generator incl. auxiliaries Nr2: Turbine Make: ELIN Type: KR 25 Rated power in relation to the generator terminals: 43oo kW Speed: 9900 rpm Steam inlet pressure max. 24 atü Steam inlet temperature max. 42o 00 Exhaust steam pressure 2 ata Normal absorption capacity 35 t/h Maximum absorption capacity 35.7 t/h Gearbox Make BHS ...
used
Steam turbine for sale. The turbine was built in 2012, is in good condition and is no longer in operation. Model SST-060 Turbine with impeller in so-called constant-pressure design ("action wheel"). The turbine rotor is mounted on two bearings and consists of the above-mentioned impeller and a shaft, which are connected to each other by means of Hirth gearing. The impeller is located outside the bearing and consists of one piece. The blades are milled out of the solid disc. Live steam pressure: 13.0 ´bara at turbine flange Live steam temperature: 191.6 ´C at turbine flange Live steam flow max: 10,000 kg/h Exhaust steam pressure: 5.2 bara at turbine exhaust flange Turbo generator sound pressure level: 92 dB(A) z 3 dB(A) measured at a distance of 1 m Coupling power: 275kW Total terminal power: The tolerance is 1.0%. 265kWe The pressure drop for the cyclone to be provided sh ...
used
2x GE Frame 6B gas turbines # Technical Summary Equipment Details - Gas Turbines: Two GE MS 6001 B gas turbines paired with AEG generators (Type S7102/2). - Operation History: - Commissioning: 1981 - Gas-fired Operation: Until 2005, primarily for base load (~7000 hours/year). - Operational Hours in Combined Cycle: - GT21: ~167,000 hours, ~1130 starts - GT22: ~159,000 hours, ~1180 starts - Retrofitted: In 1996 with water injection for NOx reduction. - Conversion: In 2007 to peak load operation using heating oil (HEL) with new steel chimneys and upgraded control systems to ABB Procontrol 14. - Operational Hours in Peak Load: - GT21: ~130 hours, ~177 starts - GT22: ~150 hours, ~180 starts - Last Network Operation: 2015 - Last Oil Service: - GT21: October 2015 - GT22: September 2016 - Last Borescope Inspection: December 2016 - Defect: Heating oil transfer line issue in 2 ...
used
Manufacturer: Ansaldo Year of Manufacture: 1999 Technical Data Listing Generator - Type: Three-phase synchronous generator GSCR 800Y4 - Power: 7,250 KVA - Voltage: 10,500V - Frequency: 50 Hz - Phase Number: 3 - Number of Poles: 4 - Rated Current: 398.8A - Power Factor: 0.80 - Rated Speed: 1,500 rpm - Spin Speed: 1,800 rpm - Insulation Heat Resistance Class: F - Ambient Temperature: 40°C - Moment of Inertia of the Rotor: 118.75 kgm² - Winding Connection: Star - Excitation Voltage Rating: 41.2/158.3V - Rated Excitation Current: 54.2/152.3A - Operation Mode: Continuous - Protection Class: IP 4 - Cooling Water Quantity: 660 l/min - Cooling Water Inlet Temperature: 40°C - Cooling Water Inlet Pressure: 4 bar - Air Inlet Temperature: 45°C - Bearing Type: Rolling bearing - Bearing A-side: EMZLB18-200 - Bearing B-side: EMZLQ18-200 - Min. Clearance Shaft/Bearing: 0.267mm - Max. Clearance S ...
used
Manufacturer: Bell Maschinenfabrik Year of Manufacture: 1988/1989 Design: Horizontal Nozzles: 2 Flow Rate (Q): 2.1 m³/s Net Head (H Net): 209.5 m Power Output (P): 3750 kW Speed: 429 min⁻¹ Operating Hours: 285,000 by end of November 2024 Pelton Wheel: PN25 DN 700 The turbine is sold completely with bearing and control hydraulics, as well as turbine governor, controller, Pelton wheel, and housings, along with supply pipes. Spare runner (11,000 operating hours) is available. Optionally, the generator, including the turbine bearings from AvK, can also be taken over: 10.2 kV, air-cooled. Find more here - / Contact us at -
steam turbine RATED POWER 1824 KW SPEED 8490 1/min pressure 19,5 bar abs exhaust pressure 0,56 bar
used
used
Qty. 1 Second-hand power plant including boiler (BFB – boiler: bubbling fluidized bed) Mfc.: Foster Wheeler, Siemens, Raumaster, YIT Corporation, Honeywell, Built: 2001, 2002, 2006, 2009 Revision: 2009 Insulation removed in 2018 BFB Boiler – 88 MW Steam turbine – 22.5 MW Main Steam Cycle BFB boiler K7 – Some parts removed and storaged indoor at the paper mill area – Boiler is made electrically safe (cables cut) – Dry conservation ongoing since 2014 (tubes filled with nitrogen, dry air circulation) – Steam Turbine VP4 (in storage) Generator (in storage) Power Plant – Function Primary function is to produce steam for the Paper Mill reliable and economically Secondary functions: Burning of the Paper Mills (PM) waste wood Incineration of sludge from the PM: WWTP Production of flue gas to the PCC (precipitated calcium carbonate) plant Electricity product ...
used
Used 3-station turbine packing machine. Dose range 5-50 kg, has a pickup conveyor and a bag-forming conveyor. YOM 90's.
used
Engine Brand: KAWASAKI, Conditie: USED, Engine Cooling Type: Oil Cooled , Engine Color: Grey , Working Hours: 1232 Hour(s), Engine Condition: Used , Turbo Type: None Mounted , Exhaust System: Dry , ECU Present?: no , Starter Voltage: 24 Volt , Rated Power: 1180 Kw, Rated Speed: 1500 Rpm, Injection Type: Mechanical Fuelpump , Generator KVA: 1250 , Generator Hz: 50 , Generator Volts: 400 , Generator Amps: 1804 , Generator Fases: 3 Fases , , https://www.hamofa.com/catalog/product/view/id/203827, , = More information =, , Empty weight: 12.000 kg, Type number: Kawasaki M1A-01 GENERATOR 1250 K
used
used very little (max 4000 hours) and are in excellent condition. ORC turbine of 160 kW electrical and about 700 kW thermal, Since 2001, Triogen has been developing and manufacturing systems for conversion Organic Rankine Cycle (ORC) energy conversion systems. The generator TRIOGEN ORC, which has been used in various application areas since since 2005, is similar to a steam cycle, but uses a fluid organic instead of water. Compared with steam, it allows to achieve better performance and efficiencies by exploiting sources of low-temperature heat. The Triogen ORC generator is suitable for the conversion of heat from: + Natural gas engines + Biogas engines + Landfill gas engines + Biomass + Biodiesel engines + Diesel engines + Gas from flares + Gas turbines + Process heat + Furnace heat + Any heat source >350 °C 165 kWe DI ELECTRICITY WITHOUT FUEL AND EMISSION-FREE ...
used
Steam Turbine 1 and major components Plant part Manufacturer Year of construction techn. data turbine VEB EKM 1970 generator VEB EKM; VEB Bergmann Borsig 1970 31250 kVA x 6,3 kV condenser VEB EKM 1970 "Bearing oil plant, pumps, "VEB Apparatebau Leisnig-Tragnitz; Filter Cooler" VEM, Siemens, VEB EKM and KSB" 1969 Steam jet cleaner Wilhelm Wigand ca. 1970 Condensate pumps VEB EKM ca. 1970 Find more here - / Contact us at -
used
Biomass CHP Boiler Plant – 5.4 MW Thermal and 995 kWe Turbine Capacity A lightly operated, complete biomass CHP boiler plant featuring a 9.5 MW bubbling fluidized bed boiler (BFB), designed for wood-based fuels. The plant includes a back-pressure steam turbine and a heat exchanger for hot water production from back-pressure steam. The plant was built by Estonian Filter Solutions, a company highly experienced in steam boiler plant engineering and EPC contracting. The BFB steam boiler was delivered by Vapor Boilers Finland. The steam turbine was manufactured by Triveni Turbines (India), in combination with a generator and controls from ABB. Other key equipment includes KSB pumps, conveyors from Technobalt AS, and rotary airlock valves from Rotolok UK. The power plant was commissioned in 2013 and operated at partial load until 2015. The control system, developed by Filter Solutio ...
used
Key Details: • Turbine: Solar Centaur 40 (Dual Fuel: Natural Gas & Diesel) • Power Rating: 3.5 MW • Total Running Hours: 40,000 since the last overhaul • Alternator: Hyundai, Air-Cooled, 3,500 kW, 50 Hz, 3,300V • Heat Recovery Boiler: Nebraska, 22-ton capacity • Gas Compressor & Control Panel included Spare parts available. Find more here - / Contact us at -
new
MWM TCG 2020 V12-Nr. MWM TCG 2020 V16
used
Unused solenoid valve for air intake from stock MWM 12072648
used
used
used
used
used
used
used
used
used
used
used
used
used
used
TEM SYSTME SCREEN RS - 12404588
used
used
used
I/01 MODUL CAMBUS RS - 12404581
used
I/01 MODUL CAMBUS RS - 12404584
used
RACK (CPU-1 / CPU-P) RS-12470974
used
AKR-KNOCK CONTROL RS - 12404594
used
AKR-KNOCK CONTROL RS - 12473957
used
AKR-KNOCK CONTROL RS - 12473965
used
SERV-SPEED GOVERNOR RS - 12404590
used
I/O PRINTED BOARD RS - 12404593
used
SERV-SPEED GOVERNOR RS - 12511709
used
used
used
used
STEP-TRIGGERING CARD RS - 12404591
used
I/01 MODUL CAMBUS RS - 12404582
maximum number of results exceeded
please refine your search