We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
120,962 used machines on RESALE, but how to find them? Machine Search
maximum number of results exceeded > 1000
please refine your search
used
White temperature cabinet Here we offer a white temperature cabinet. Air-cooled White temperature cabinet with S! MCON / 32 controller Test room capacity : approx. 195 litres Test room dimensions: height 750 mm, width 580 mm, depth 450 mm, External dimensions: height 1775 mm, width 870 mm, depth 1600 mm, Data for operation: Test room lighting halogen bulb 24V, 50W Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz Rated current: 14 A Data for temperature tests: Temperature range: -42 to +180 °C Temperature deviation temporally in the middle of the usable space: ± 0.1 to ± 0.5 K Temperature deviation spatially: ± 0.5 to ± 1.5 K Temperature change rate Heating: 4 K/min Cooling: 4 K/min Heat compensation max. 2300 W Refrigerant: R404 A 2.5 kg Gwicht : 490kg Type: WT3 - 180/40 For you as a buyer for security the following information! The following points are ...
used
GBS test pulse rev3 pulse generator for long-term insulation tests The test pulse structure is intended for long-term insulation tests on test specimens of up to 6 nF capacity. Inverter for high-voltage test transformer · Internal sine wave generator: 50-200Hz. · Pulse width modulation 16-24kHz of the sine over full bridge. · Inverter voltage 0-600V adjustable, Imax=2.6A, maximum power 1.3kW · Pulse current limit 110A (cut-off threshold) Pulse transformer – control · Control via full bridge · Full bridge power supply adjustable 0-1000V, 1.3A max. · Pulse current limit 100A (cut-off threshold). · Pulse width 20-120μs, nominal 94μs, adjustable · 2 selectable series inductors 150μH, 300μH to adjust the pulse width or rise times to load capacitance and voltage. · Pulse repetition rate 0.1 – 2.5 kHz, adjustable. · Polarity: Adjustable positive, negati ...
used
Espec Temperature Shock Chamber Here we offer you an Espec temperature shock chamber. Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large, since three separate chambers are used. The TSA series has only one chamber, which significantly reduces its size. Instead, it circulates cold, hot or ambient air as needed. The air-conditioned air can be pre-cooled or preheated beyond the setpoint, allowing for faster recovery of the desired state after transmission. Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154 Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C Working temperature: 0-40°C System: Two zones or three zones test by flap switching Achievement: Test area: High temperature. Exposure range: +60 to +200°C Low temperature. Exposure range: –70 to 0°C Temperature fluctu ...
used
Genset Model C22 D5, 22kVA Standby, 20kVA Prime, X2.5G2, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X2.5G2 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144D, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coo ...
used
C28 D5 Enclosed A044B088 Genset Model C28 D5, 27.5kVA Standby, 25kVA Prime, X2.5G2, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X2.5G2 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144F, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, G ...
used
C33 D5 Enclosed A044B089 Genset Model C33 D5, 33kVA Standby, 30kVA Prime, X3.3G1, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X3.3G1 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144G, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% W ...
new
C38 D5 Enclosed A044B090 Genset Model C38 D5, 38kVA Standby, 35kVA Prime, X3.3G1, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine X3.3G1 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator PI144H, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% W ...
new
C44 D5 Enclosed A041C003 Genset Model C44 D5, 44kVA Standby, 40kVA Prime, S3.8G4, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire ENGINE S3.8G4 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC224C, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical, Flange On Connection Inlet 3 Inch, Outlet ...
new
C66 D5 Enclosed A041C011 Genset Model C66 D5, 66kVA Standby, 60kVA Prime, S3.8G7, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire ENGINE S3.8G7 Engine Air Cleaner - Duty Rating : Normal Duty Engine Oil Heater : None Supplied Engine Speed Governing : Mechanical Droop Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC224F, 12 Leads, 50 Hertz (Hz), 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical, Flange On Connection Inlet 3 Inch, Outlet ...
new
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mo ...
new
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C170 D5 Enclosed A047W024 Genset Model C170 D5, 170kVA Standby, 155kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G7 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C400 D5e Enclosed A029Z631 Genset Model C400 D5e, 400kVA Standby, 364kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC4F,50Hz,12 Leads,190 - 220V & 380 - 440V125C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 630A,690V IEC, 600V UL,4 P ...
new
C500 D5 Enclosed Genset Model Item C500 D5, 500kVA Standby, 455kVA Prime, 0, 0, QSZ13G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SII Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSZ13G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC5C, 12 Leads, 50 Hertz (Hz), 190 - 220V and 380 - 440V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclo ...
new
C550 D5e Enclosed A029Z751 Genset Model C550 D5e, 550kVA Standby, 500kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC5D,50Hz,12 Leads,200V & 400V150C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 800A,690V IEC, 600V UL,4 Pole,100%,Left C ...
used
Camp No: G15814 Type of machine: Tooth flank test device Factory: Mahr Type: 891 S built: 1986 Technical data Evolve test machine Wheel diameter up to 600 mm Module 0.2-20 mm Power 1.2 KW Weight 1.3 to Technical data The machine is used to test: Tooth flank shape (profile shape) ' tooth direction (flank line), round deviation + surface quality on forehead wheels of all kinds Wheel diameter up to 600 mm Wheel width up to 60 mm Module 0.2 to 20 module Savenboard angle 0 to 90 ° Trouble magnification 250/500/1000 times Workpiece weight up to 100 kg Vertical adjustment 150 mm Machine dimensions (LxBxH) 1,200 x 1,200 x 1,600 mm Weight approx. 1300 kg Power requirement 1.2 KW Accessories and equipment: Scribe, div. registration paper, div. tips, takeaway intermediate rope for top increase by 200 mm, mech. Key head, teaching tooth wheel
used
White Temperature Chamber Here we offer a white temperature chamber. White temperature chamber water-cooled Temperature range: from - 70°C to 180°C Temperature change rate cooling 10 K/min Temperature change rate heating 10.0 K/min Temperature deviation in time ± 0.1 to ± 0.5 K Temperature homogeneity spatially ± 0.5 to ± 2.0 K Test room dimensions: width 580 mm x depth 615 mm x height 750 mm Housing dimensions: width 895 mm x depth 2080 mm x height 1950 mm Voltage: 3/N/PE AC 400V±10% 50Hz Rated power 14 kW Rated current 26 A Refrigerant: R-404A R-23 Weight: approx. 450 kg Control panel has been updated to a 24 volt version Type: WT11-270/70/10 For you as a buyer for security the following information! The following points are carried out in advance at our offered chambers: 1. Functional check and replacement of necessary components 2. New filling with le ...
used
Angelantoni / ACS Climate Chamber Here we offer you an Angelantoni / ACS climate chamber. Angelantoni / ACS climate chamber with humid air-cooled Test ram volume 567 liters External dimensions: width 1100 mm x depth 1705 mm x height 1910 mm Internal dimensions: width 850 mm x depth 746 mm x height 895 mm Characteristic values for temperature tests Temperature range -40°C to +180°C Maximum temperature change rate from -40°C to +180°C 3.2 K/min Maximum temperature change rate from +180°C to -40°C 2.5 K/min Heat compensation at -25°C. 1000 W Characteristic values for climate tests Temperature range: + 10°C to +95°C Humidity range: 10 % to 98 % RH Accuracy 0.25÷0.3 Rated voltage: 400 +6/-10% 50Hz 3+N+T Rated power: 11 kW Rated current: 20 A Fuse on site: 12.1 A sluggish Refrigerant: R404 A Weight: approx. 820 kg Type: CH600 For you as a buyer for security ...
used
WSM Stationary screwdriving unit screwdriving station Assembly of parts for car radios and navigation systems and for testing them. The assembly station is surrounded by a protective enclosure. The service doors are equipped with interlocking monitoring switches. The doors are locked in automatic mode and can only be opened when the automazik stop or in manual mode after pressing the doors on the control panel. When the door is open, automatic operation cannot be started. Functional sequence The station is equipped with the pre-assembled assembly via the transfer belt. The work steps of the automatic station with a run of a WT are described below. In normal operation, all 3 stations work in parallel. - Positioning the WT with the pre-assembled assembly in St.2.1 - Lowering the wearer with the scanner and the vision sensor - Scanning of the 3 codes (front panel, fro ...
used
Chilworth JCI 164 High Voltage Adapter General description The JCI 146 is a voltmeter adapter component designed for integration into wider experimental systems. In combination with our JCI 140, the system enables the measurement of live conductors with voltages up to ± 60 kV DC by direct connection with an accuracy of ± 2% (nominal) with minimal load effects on the device under test. The JCI 146's high input impedance and low capacitance are suitable for more accurate DC voltage measurements. Other traditional techniques for directly measuring high voltages (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often provide inaccurate results due to load effects caused by the measurement setup. This device can be used to cross-check the calibration and accuracy of high-voltage sources by power utilities, calibration test houses and cable manufacture ...
used
Machine type TIG welding system gas-cooled DC and AC system Brand Werner Type AGW 235 Supply voltage 3 x 400 volts Setting range 10 – 230 amperes Duty cycle 35 % ED at 230 amps 60% ED at 160 amps 100% ED at 120 amps Current adjustment infinitely variable weldable material thickness 6 mm Cooling transformer by built-in fan Cooling burner gas-cooled Design of mobile industrial plant Fuse 32 Ampere Dimensions L x W x H 880 x 410 x 610 mm Weight approx. 150 kg Age approx. 20 years Condition workshop-tested very good incl. UVV test report Scope of delivery welding system with the following accessories: 1 piece TIG burner 4 mtr. long 1 piece ground cable 1 pressure reducer with 2 pressure gauges 1 pair of TIG gloves 1 piece spare parts box kpl. Equipped Warranty 6 months from date of delivery Original price 3.500,00 € + ...
used
BOSCH Type KLD 1041 Leak Test Machine for Ampoules and Vials Leak test machine for glass containers. Linear automatic machine for the inspection of ampoules, injection cylinders/cartridges and injection bottles/vials, which checks each container at four inspection points by means of high-voltage technology. The testing principle is based on the detection of the changing impedance of a container filled with an electrically conducting liquid. The containers are examined for: hairline fissures and pinholes ; insufficient glass wall thickness/tip domes too thin ; capillary pores ; leaking fusion points, sealing points and ampoule neck tips ; absence of fill. MAIN FEATURES: It is recommended to carry out the container leaktightness test directly after sterilization or fusing. The unit is equipped with: conveyor system, infeed belt, 4 high-voltage inspection stations (1-2 check bodies and ...
used
Merkle Insquare 300 AC/DC welding system Primary: Voltage: 3 x 400 V Frequency: 50 (60) Hz cos phi: 0.95 TIG DC Range: Open circuit voltage: 80 V Working voltage: 10-22.8V Welding current: 5-320 A HSB 60 % d.c. (10 min.) 320 A HSB 80 % d.c. (10 min.) 300 A DB 100 % DC: 260 A (40°C) Continuous power: 9.5 kVA Primary continuous current: 13.7 A Primary Maximum current: 19 A TIG AC Range: Open circuit voltage: 80 V Working voltage: 10-22.8V Welding current: 5-320 A HSB 60 % d.c. (10 min.) 320 A HSB 80 % d.c. (10 min.) 300 A DB 100 % DC: 260 A (40°C) Continuous power: 9.5 kVA Primary continuous current: 13.7 A Primary Maximum current: 19 A Electrode welding operation: Rod electrodes: 1.5-6 mm Open circuit voltage: 80 V Working voltage: 20-32.8V Welding current: 5-320 A HSB 60 % d.c. (10 min.) 320 A HSB 80 % d.c. (10 min.) 300 A DB 100 % DC: 260 A ...
used
A set of test pens is sold 1 set of test pins measuring range 0.5-5.45mm measuring distance 0.05mm steps This set is missing 2 pins 3.2mm and 3.35mm 1 set test pins Measuring range 5.5-10,00m measuring distance 0.05mm steps Exact grade 2 Tolerance 0.002mm
used
Pamasol P2065 Leak Detector with 5 Test Heads Leak detector In order to ensure that pressure-proof and non-hazardous printed packs are available on the market, alternative test methods can also be used for safety testing – before and after filling. One of these methods is the leak detector after filling. The aerosol containers (monobloc only) are tested for leaks in the valve area and at the container neck. Different power ranges are available. Application industrial, packaging, plastic containers Range Individual stations Output on feed units: up to 50 containers per minute Capacity on rotary stations: up to 250 containers per minute Leak Detector 2065 Leak detector for testing the aerosol container (monobloc) for leaks. - Feed with 12-piece rotating star; electric drive - 5 test stations with sensor heads for a can shoulder shape - Automatic ejection of faulty ...
used
Climatic test chamber ACS DY110 - Year of construction 2021 - Acquisition January 2022 - approx. 500 operating hours - Sale due to completion of product development / testing Specifications: - Dimensions test room: 548 x 447 x 447 mm - Test chamber volume: 110 l - Working range temperature tests: -40 to +180°C - Working range climate tests: +10 to +95 °C and 10 to 95 % relative humidity - Nominal power 3 kW, connection to 1/N/PE AC 230V 50Hz via CEE Qualifications: - 2006/42/CE Machinery Directive - 2014/35/UE Low Voltage Directive - 2014/30/EU Electromagnetic Compatibility Directive - IEC 61439-1/2 Low Voltage Switchgear Assemblies - IEC-60204-1 Safety of machinery - Electrical equipment of machinery - IEC 61000-5-2 Installation and Interference Suppression Guidelines - Section 2: Grounding and Wiring - IEC 61000-6-2 Generic Standards - Immunity Standard for Indu ...
new
Cylindrical storage tank, factory new Capacity: 60 cbm / Medium: Fuel oil Material: S235JR (St 37.2) raw inside, blasted outside, primed and painted in RAL 7035 - light grey Dimensions: 2,500 mm diameter, 12,650 mm full length Design: according to DIN 6616/2 or DIN EN 12285-2, double-walled Test pressure inner tank 2 bar test overpressure Double jacket 0.6 bar incl. control fluid in double jacket for above-level storage with test certificate and documentation Container equipped with GOK Lag 2000 and limit sensor as overfill protection Equipment: 1 dome 600 mm li.W. with cover, gasket and screws 3'' filling cable with TW coupling 3'' Vent with cap 1 1/4'' Suction line with reduction to 1'' 1'' for limiter GWG 23-Ro 1'' nit dipstick 2'' reserve 1 pair of permanently welded steel saddle feet 1 suspension ladder with pedestal, galvanized according to UVV ...
used
It is used in rubber and plastics mixing, warming mixing, sheeting mixing, etc. III Equipment specification XK400×1000 mixing mill 1. Main technical specification NO. Item Main technology data and feature A Main technology data 1 Roll diameter 400mm 2 Roll working length 1000mm 3 Roll linear speed Front:14.85m/min Rear:18.85m/min 4 Speed ratio of rolls 1:1.27 5 Max roll space 10mm 6 Compound feeding capacity 25kg-35kg 7 Motor power 37KW,n=980r/min,IE3 8 Dimensions 4400X1710X1850mm 9 Gross weight 8500kg B Feature of main machine 1 Roll size(mm) Ф400×1000 material alloy chilled hard cast iron, surface hardness HS70±2,Surface roughness: Ra0.2 Bearing type Adopt the aligning roller bearing, copper pressure ring, bearing taper 1:12 type Front roll is drilled roll and rear roll is drilled roll, can pass cooling water, e ...
new
Heating oil tank Tank system Diesel tank and other hazardous substances. 50,000 litres capacity according to EN 12285-2 standard, above ground, double-walled incl. officially recognized test certificate. Tank Environmental Protection Wozniack . Specialist company according to § 19 Water Resources Act (WHG) offers as follows. Storage tank 50,000 litres double-walled new according to EN 12285-2 standard . The container is new and will be equipped with the following fittings: 1 optical leak detector with type approval and leakage liquid (new) 1 filling tube with TW closure (filling cap) and immersion tube, 1 bearing tube with dipstick and dipstick closure, 1 vent pipe with ventilation hood, 1 brand-new limit encoder with type approval (AIII)(new) 1 conductor Container dimensions Length 10.7000 mm Diameter 2500 mm Weight approx. 9.000 kg Of course, y ...
new
dreizler® dual-fuel burner in DUObloc version Operation infinitely variable modulating (gas and oil) CE certified and compliant with EN 676 gas burner with blower and EN 267 oil burner and the EU directives EU/2016/426 Gas Appliance Regulation and 2006/42/EC Machinery Directive Dual-fuel burner according to EN 676: • DUObloc version: fan separately on base frame with vibration damper, electric motor and fan wheel in sheet steel housing, with protective grille and compensator on the discharge port • Burner housing with gas/oil/air mixing device for the combustion of natural gas and liquefied petroleum gas and EL fuel oil, other liquid or gaseous fuels on request • Two-pole ignition transformer device for direct ignition of gas and oil flame • Flame monitoring via optical flame detector • Gas deficiency protection and air deficiency protection on the burner ...
used
Balance, calibration weight, test weight, calibration weight, taring weight -Calibration weight: test weight calibration weight for scales -Test weight: 1 kg -Dimensions cover: Ø 60 x 94 mm -Weight: 1.0 kg
used
General SKU430T1359 LocationBarneveld MakeIKA werke GmbH TypeMHD 2000/5-ATEX No.07-6301 Year of construction2007 Main Features MaterialStainless steel Motor5.5 KW Rotor60 mm Specified Features - Inline mixer Continuous reactorcheck Rotor sizesDia:60x15mm InletDN50 OutletDN32 Number of stages:1 Capacity700l/h With jacketcheck With mechanical sealcheck Motor5,5kW, 400/690Volt, 2880rpm (EX) Rotor speed6000rpm With vesselcheck Capacity100ltr Vessel sizesDia: 500x450mm MaterialStainless steel 1.4404 (316L) Information Mounted on framecheck Total height2,5m Weight550kg CEcheck Floorspace1,65x1,1m ATEX compatiblecheck Extra SpecificationsThis IKA Werke is equipped with additional items. A barrel of the brand AZO for mounting on top of the IKA Werke. Type: V150 Serial number: 15565-01-2007 Working pressure -1- 3.5 bar Test pressure: 5 bar Operating temperature: ...
used
Manufacturer Angelantoni ACS Model DY 110 Operating condition Used (as good as new) Year of construction2021 Value added tax Deductible DescriptionClimate test chamber ACS DY110 - Year of construction 2021 - Acquisition January 2022 - approx. 500 operating hours - Sale due to completion of product development / testing Technical data: - Test chamber dimensions: 548 x 447 x 447 mm - Test chamber volume: 110 litres - Working range temperature tests: -40 to +180°C - Working range of climate tests: +10 to +95 °C and 10 to 95 % relative humidity - Rated power 3 kW, connection to 1/N/PE AC 230V 50Hz via CEE Qualifications: - 2006/42/CE Machinery Directive - 2014/35/UE Low Voltage Directive - 2014/30/UE Electromagnetic Compatibility Directive - IEC 61439-1/2 Low-voltage switchgear and controlgear assemblies - IEC-60204-1 Safety of machinery - Electrical equipment ...
used
General SKU394U1125 LocationBarneveld MakeLauda TypeTR 400 HK-EX Mach.No.HSK0835 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit Thermal oil heaterTherminol D12 Water heaterWater/Glycol Heating medium:Oil/Water/Glycol Electric capacity12.9 kW, 400 volt (ex) Temperature-40°C/+200°C With pumpcheck (2x) Capacity18 m³/h Motor5,5 kW, 400/690 volt, 2880 rpm (EX) (2x) MaterialStainless steel 1.4571 (316Ti) Information Year of construction2008 Mounted on framecheck CEcheck Floorspace2.20x1,0 m Total height2,30 m ATEX compatiblecheck Extra SpecificationsThis Lauda is equipped with a heat exchanger. Brand: Merck Built by: Herbst Maschinenfabrik GmbH Factory number: 08-12583-26/1 Material: 1.4571, Stainless Steel 316TI Jacket data, pressure: -1/+16bar, test pressure: 25.2bar ...
used
FEEDSTOCK TUBE external diameter min.: 10 mm external diameter max.: 90 mm Exclusions from supply (even when visible on photos): The equipment is supplied without test equipment and electronics, in particular without: - Ultrasonic system incl. digitization- test process Krautkrämer and measuring devices - Ultrasonic measuring device- Length differences >500 mm Sorting out Krautkrämer- Förster Defectomat continuous spool- Replacement mix-up test Krautkrämer
used
FEEDSTOCK TUBE external diameter min.: 22 mm external diameter max.: 140 mm wall thickness min.: 1 mm wall thickness max.: 14 mm length min.: 4500 mm lenght max.: 12500 mm Exclusions from supply (even when visible on photos): The equipment is supplied without test equipment and electronics, in particular without: - LMD test spool nominal size 120- Nukem test system installation cabinet- Steel checker plates (safety protection)- Defectomat pass-through spool- Ultrasonic and wall thickness testing system NUKEM - Replacement demagnetization Nukem- Replacement inspection electronics
used
Clampable cutter head type (max.): 460 mm Cutter head weight (max.): 150 kg Mounting disc diameter for cutter heads (Ø): 360 mm Mounting cone for cutter heads Nominal diameter: Ø 58,227 mm travel -z axis: 200 mm diagram-drawing enlargement: ±10 - ± 500 µm weight of the machine ca.: 2,3 t dimensions of the machine ca.: 2 x 1,5 x 2,03 m In the manufacturing process for spiral-toothed bevel gears, the quality of the gear cutting gear cutting tools used plays a decisive role. Particularly in high gear cutting quality and a long service life can only be achieved with precisely can only be achieved with precisely adjusted cutterheads. The Oerlikon cutterhead setting and testing device CS 200 enables quick and easy setting of the individual knives and simple adjustment of the individual knives, it checks the position and documents the measurement results. The measuring sequence on the CNC- ...
used
For transport and storage of all types of beverages ex: bier, wine, juice, liquor, whiskey. For yoghurt, mustard, honey, cream for hands, etc. Also for pharma and chemical purpose. Material: Cone: 1.4301 IIID Jacket: 1.4301 IIID All other parts: 1.4301 IIIC Volume: 1000 litre Test pressure:+ 3,4 bar Max. allowable: Operating pressure:+2,0/-0,15 bar Operating temperature:130°C Dimensions: Height over all:1845 mm +/- 10 mm Diameter of container:1000 mm Diameter of reinforcing ring:1012 mm Weight: 126 kg Thickness: Top Bottom:2 mm Lid:3 mm Jacket:1,5 mm Cone:2 mm Outlet Tube:2mm Forklift Tunnel:3 mm Design and Equipment: stacking device - consisting of a stacking crown which is welded directly on the top bottom; Top Bottom: with a DN 400 cover system which is welded in the center of the top bottom; Cover System with a DN 400 lid which ...
used
Cat. No. 11-4105 in very good condition Material: V2A - AISI 304, 1.4301- Surface: inside and outside 2B=IIIC Topsoil: with manhole pressure cap 1.5 bar test pressure DN 400 with 6 star head screws, with handle bracket, Threaded welding nozzle DN 50 Tank body: manhole 430x300 mm Underbody: Konusboden 45 with forward-drawn outlet pipe with disc valve DN 65, with forklift shoes, with stable frame, with pallet lift truck all sides underpassable. Test pressure: 1.5 bar Working pressure: 0.99 bar DxH: 1100 x 2200 mm - Weight: 230 kg Supplements/pieces (on request): Fermentation spandconnection DN 50 Euro Trial tap Blind cap DN 50 Fermented spundar fitting CIP Cleaning The price is for a tank. For inquiries: Tel: 09353 90905-0 or Fax: 09353 90905-22 Mobile: 0171 651 82 48 On request, we will be happy to send you our c ...
used
Drum sieve used for SM518 new in stock! Used Drum Screen for SM518 new in stock! Punching: 10 mm rectangle; Material thickness: 6 mm perforation: 10 mm rectangle; Thickness: 6 mm Condition: used/ as good as new (screen drum was only used for one test) Condition: used / like new (drum was only for a short test in use) Available: immediately Available: immediately Location: 77966 Kappel-Grafenhausen (near Freiburg) location: 77966 Kappel-Grafenhausen/ Germany (Near Freiburg) We are happy to organize the transport for you! We can arrange transport for you! We also supply new or other used screen drums to all common screening machines (SM620, SM618, T4, T5, Mustang,). Manufactured in our factory in Germany from German, very high-quality, sharp-edged perforated sheet metal. We also provide new or used screening drums for all standard machines (SM620, SM618, T4, T5, ...
used
Cat.-No. 13-0290 in very good condition Operating pressure test at 2.0 bar Test medium: water at 22 ° C at 1 bar pressure Capacity: 2400 l / h Engine power: 2.20 kW, 50 Hz Connections: inlet and discharge pressure DN 65, thread according to DIN 32676 -can be converted against extra charge With frequency inverter infinitely variable (surcharge) on request Dimensions and weight: Length: 850 mm width: 380 mm height: 770 mm weight: 125 kg Note: 100% pump all prices apply ex works plus gesetzl.MwSt tested with warranty. Delivery: from 97753 Karlstadt Karlsburg freight expenses: reserved to standard equipment sale
used
Warman ®, AH, ® pump 4/3, AH type: 4/3, AH storage: C standard number: WP35758 Hydrostatischer test pressure: 14 cash speed: 2751 the pump is as good as new. It was carried out only one test flow with the pump. from the cyclone supply up to regrinding, Flotation and departures is the Warman ®, AH, ® pump the best choice.
used
Cat No. 16-00137 in a very good condition Measurement and Weight: Total Height: 4450 mm Tank Body Height: 4000 mm Diameter: 2250 mm Weight: 3400 kg Uni 4950 Operating-overpressure: 8 bar, Test pressure: 10,5 bar Operating pressure double jacket: 2 bar, Test pressure: 2,6 bar Inspection book, Dokumentation available Tank-Description Container with torispherical bottoms. Bottoms wall thickness and jacket wall thickness inside container 11 mm. On cylindrical part of a cooling jacket about 2,30 m high as double jacket. Container outside approx. 100 mm isolated, with screw stainless steel metal cover. Tank upper body: · filling connection DN 50 central in the upper bottom, 2 sleeves 3/8”, 1 flange piece NW 25, 1 flange connection NW 80 Tank body: · with ladder hook up · with Manhole oval 450 x 350 mm swiveling · with downwa ...
used
The following completely reconditioned and ready compact system of SEPARATORS & SERVICE T.D. is for sale. This selfcleaning separator WSPX 303TGP-71 is clean mainly used water-based coolant, for the concentration of washing liquids like lye also waste water or rain water cleaning. The maximum hydraulic throughput capacity is 1500 l / h. The engine is a two-pole motor with 50 Hz 2.2 kW. The drum has a speed of 9516 RPM 69 DB (A). Control water consumption is 0.5 l / emissions per output. Sediment volume ca: 0.63 liters. Output of min 0.8 liters, max 0.9 litres. The separation is carried out in the separator drum which is driven by the electric motor via a flat belt. The separator can be used as a concentrator with a large heavy phase (E.g. water) and a small stage (E.g., oil), as well as the light phase. The separator can be used as well as cleaning separator (Klarifikator) with o ...
new
QUASAR 1200 kN tractor / universal testing machine This is the replacement for an outdated, uneconomical hydraulic tractor testing machine / universal testing machine. Concerns when purchasing a used (hydraulic) universal test machine that will almost certainly be modernized with new electronics for WIN 7 or 10. In addition, used machines often have other (hidden) defects, such as a knocked-out central spindle of the lower clamping head. Quasar 1200 kN with the latest technology (BECKHOFF electronics) with first-class software LabTest. Suitable for tensile tests, pressure tests, bending tests and cyclic tests stable 2-acid universal test machine designed by finite elements FEM for tests on steel, reinforced steel, screws, wire ropes and much more Very well Made in Italy | Europe, e.g. with German + European quality components + assemblies ergonomic design, flexible, fut ...
new
C350 D5 Open A019J715 Genset Model C350 D5, 350kVA Standby, 320kVA Prime, NT855G6, Diesel, Open Emergency Standby Power (ESP) Emission Level; No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NT855G6 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4E, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole, End ...
new
C400 D5 Open A019J729 Genset Model C400 D5, 400kVA Standby, 360kVA Prime, NTA855G4, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G4 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4F, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole ...
new
C440 D5 Open A019J736 Genset Model C440 D5, 440kVA Standby, 400kVA Prime, NTA855G7, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G7 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HC5C, 50Hz, 12 Leads, 380-415V, 150C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 800A, 690V IEC, 600V UL, 4P ...
used
FOR SALE STANDARD SIZE MEASURMENT CRANKSHAFT OF MAK 6M 332AK TO WHOM AT MAY CONCERN; THE CRANKSHAFT HAD BEEN PUT ON V BLOCK AND FOLLOWING TESTS HAD BEEN CARRIED OUT. -Main and crankpin journals measurements had been carried out. -MPI test had been carried out and no. crack had been observed. Crankshaft were found typical. -Run-out measurement had been carried out found in good order. -Hardness test had been carried out to all crankpins and main bearing journal. All values had been found in permissible limits. -Crankshaft had been polished. CRANK SHAFT READY TO TRANSPORT AT IZMIR - TURKEY. WITH FULL SEVICE REPORT IF YOU'VE ANY FURTHER QUESTIONS PLS DO NOT HESITATE TO CONTACT WITH US. Capt. Ayhan Ugurluba Best regards; Aliaga marine services E mail: info/aliagamarine.com PHN/fax: +90 232 618 03 90 Mobile: + 905556084850 .aliagamarine.com TURKEY ...
new
ZKG tanks / storage tanks / tank / pressure tanks in V2A with cooling jacket and insulation Operating pressure: 3.0 bar test pressure: 4.0 bar Capacity: 2,800 litres NEW! Surface: inside and outside 2B = IIIC material: V2A (AISI 304) 1.4301 Top shelf: â?¢ with 2 loops â?¢ with threaded weld NW 25 â?¢ with CIP cleaning NW 40 â?¢ with below drawn pipe DN 32 with fermentation sheet pile valve (with pressure relief valve, with pressure gauge)(gegen Aufpreis) Tank cylinder: â?¢ with wire hook up â?¢ with manhole oval 430 x 330 mm, with handle â?¢ with cooling jacket H = 750 mm and with insulation â?¢ with test valve DN 15 with spiral in V2A (extra charge) â?¢ with Tauchschafthülse with temperature display (extra charge) â?¢ on the back of the tank 2 x connecti ...