The Pall CFS system is designed as a single unit and can be installed
directly in front of the filling line without the need for a buffer
system. It is a completely independent process unit consisting of the
following components: filter vessel Piping and connections Membrane
cleaning system (CIP) integrity check Switchboard The hygienic design,
the simple integrity test and the full automation ensure the
microbiological safety of the system and usually allow the operation
of the filling staff. Cluster filtering groups filter elements into
clusters. Each cluster has its own outlet valve. During filtration,
all clusters are open. Cleaning, sterilization and integrity testing
are performed per cluster. Advantages of the CFS principle; Longer
life Integrity testing on site Integrity diagnostics per cluster
Special rinsing High specific flow rate Short flush times Constant
flow in all candles Minimal water consumption Quick replacement of
filter elements Controlled backwash Minimal beer loss High biological
safety Constant availability With this filter system only preclarified
products may be filtered, which have normally filterable properties in
their composition., Max. filtration flow: 400 hl/h continuous,
Permissible operating pressure: 6 bar, Permissible operating
temperature: 105 °C, Volume: 1456 l, Current: 10 A, V51233327
Voltage: 220 V, Water: cold water: min. 150 hl/h; hot water (max 65 °
C): min. 150 hl/h, Compressed air: prepared compressed air: 4 - 6 bar;
control air: 5 - 8 bar, Length: 1,40 m, Width: 1,20 m, Height: 1,85 m,
Weight: 3450 kg, Base construction: basic frame with control and
measuring components and filter container; cleaning module, Features:
98 filter cartridges, 3 piston diaphragm pumps (Dosage), centrifugal
pump with frequency converter (WT circuit), various analog and digital
sensors (flow, pressure, level, temperature, conductance), various
valves, control cabinet