Koch Membrane Systems (GEA Tuchenhagen computer designed) Ultra
Filtration (UF) plant for continuous circulation / concentration /
filtration and the production of cream cheese. Once the plant is
running continuously with ratio control, no manual interventions are
generally necessary for the production of the UF concentrate. However,
for optimal production of consistent quality, strict adherence to
various prerequisites is necessary, e.g. regarding cleaning. Line
still located at its original position in the dairy in Austria., The
Ultra Filtration line exist out:, - Level tank, 750 liter., - Product
feed pump (P1), Tuchenhagen VPB 32 L, 5.000 ltr/h, 39 mWs, motor 3 kW
- 2.900 rpm - 380 V - 50 Hz., - Permeate pump (P2), Tuchenhagen VPB 32
L, 5.000 ltr/h, 35 mWs, motor 3 kW - 2.900 rpm - 380 V - 50 Hz., - CIP
pump (P3), Tuchenhagen VPD 51, 110.000 ltr/h, 8 mWs, motor 7,5 kW -
1.450 rpm - 380 V - 50 Hz., - Circulation pump stage 1 (P101),
Tuchenhagen VPC 52 L, 32.000 ltr/h, 50 mWs, motor 15 kW - 2.900 rpm -
380 V - 50 Hz., - Circulation pump stage 2 (P201), Tuchenhagen VPD 42
L, 80.000 ltr/h, 30 mWs, motor 22 kW - 2.900 rpm - 380 V - 50 Hz., -
Circulation pump stage 3 (P301), Tuchenhagen VPD 52 L, 80.000 ltr/h,
45 mWs, motor 22 kW - 2.900 rpm - 380 V - 50 Hz., - Concentrate
discharge pump (P31), Seepex 5-12BC, 250 - 2.500 ltr/h, 80 mWs, motor
1,5 kW - 55 - 215 rpm - 380 V - 50 Hz., - Ultra Filtration Filters,
Stage 1, 4x pieces S3 house with Standard Flow Membranes (max 6x)., -
Ultra Filtration H51253732 Filters, Stage 2, 4x pieces S2 house with
High Flow Membranes (max 6x)., - Ultra Filtration Filters, Stage 3, 4x
pieces S2 house with High Flow Membranes (max 6x)., - Homogeniser, APV
Gaulin, 396 MC 4-3TPS, year 1995, 95L34675 1.500 ltr/h, 200 bar, motor
15 kW., - All interconnecting piping, flowmeters and valves., -
Separate standing stainless steel control panel with simple controls.,
P&ID and technical description in German language available., Type of
Machine: Ultra Filtration (UF) plant, UF capacity input: 3.000 ltr/h,
UF Retentate output: ± 1.300 ltr/h with a dry matter of 38%, UF
Permeate output: ± 1.700 ltr/h, Flowchart no: 50-10-1940079