122,178 used machines on RESALE, but how to find them? Machine Search
used
Transformer, single phase power transformer, single phase transformer, single phase isolation transformer, single phase isolation transformer, isolation transformer, solid rubber distributor -Manufacturer: ismet, single-phase isolation transformer type KSTK 2500 -Power: 2500 VA -Technical data: see photo nameplate -Dimensions: 315/270/H275 mm -Weight: 29 kg
used
Limit signal generator, logic controller, trip point control, multisafe switching amplifier, level monitor, signal isolator, isolation amplifier, isolation amplifier -Manufacturer: Turck, multi safe signal isolator isolation amplifier -Type: MS91-12-R -Quantity: 1x module available -Dimension: 115/50/H75 mm -Weight: 0.4 kg
used
Single-phase isolation transformer, isolating transformer, solid rubber distributor -Manufacturer: Foster, transformer isolation transformer -Type: 1FT22 82 -Primary: 220V 50Hz -Secondary: 42 V see photo nameplate -Power: 1kVA -Number: 3x transformer available -Price per piece -Dimension.: 350/220/H210 mm -Weight: 17 kg/pc.
used
Isolation amplifier SCHUHMANN MESSTECHNIK TV1.04G Input: 0 - 60 mV DC Output: 4 - 20 mA Supply voltage: 230 V AC unused ! Dimensions: 80 x 25 x 105 mm
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU 3 UI 120/75 ( 3UI120/75 ) 5.0 kVA Prim. 3 x 400 V sec. 3 x 220 V AC 13.12 A 50 - 60 Hz Ersatzteil für TRAUB TND300 ! used, checked ! Dimensions: 240 x 155 x 200 mm
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU RDRKL 25 S ( RDRKL25S ) 0,8 kVA Prim. 3 x 380 V sec. 24 V DC 25 A 50 - 60 Hz Spare part for TRAUB TND300 ! used, tested, with downstream three-phase bridge rectifier ! Dimensions: 210 x 210 x 190 mm
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU RDRKL 10 S ( RDRKL10S ) 0,34 kVA Prim. 3 x 380 V sec. 24 V DC 10 A 50 - 60 Hz Spare part for TRAUB TND300 ! used, with downstream three-phase bridge rectifier ! Dimensions: 165 x 155 x 160 mm
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU RDRKL 30 K ( RDRKL30K ) 0.9 kVA Prim. 3 x 220 V sec. 24 V DC 30 A 50 - 60 Hz with downstream three-phase bridge rectifier ! used, tested ! Dimensions: 210 x 210 x 210 mm
used
PTC relay, contactor, semiconductor contactor, contactor, relay, isolating amplifier, power supply -Manufacturer: Phoenix Contact, isolation amplifier / power supply ovp -Type: MCR-PS-24DC/10DC -Order No.: 27 66 68 5 -Number: 2x relay available -Price per piece -Dimensions cardboard: 115/110/H30 mm -Weight: 0.1 kg/pc.
used
Isolation transformer EAW, GERÄTEBAU BRIESELANG Typ 75/25 TGL 200-1764 0,16 kVA Prim. 220 - 380 V AC sec. 24 - 42 V AC 50 - 60 Hz IP 20 In metal housing ! unused ! Dimensions: 215 x 155 x 140 mm
used
PTC thermistor relay, contactor, semiconductor contactor, contactor, relay, isolating amplifier, converter -Manufacturer: Phoenix Contact, isolation amplifier / converter unused original packaging -Type: MCR-C-UI-UI-DCI -Order No.: 2810913 -Number: 1x relay available -Price per piece -Dimensions cardboard: 115/110/H30 mm -Weight: 0.2kg/pcs
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU DRUI 4400 ( DRUI4400 ) 20 kVA Prim. 3 x 475 - 525 V AC sec. 3 x 400 V AC 28.8 A 50 - 60 Hz unused ! Dimensions: 300 x 180 x 260 mm
used
Single-phase isolation transformer, isolating transformer, solid rubber distributor -Manufacturer: Gifas, isolating transformer solid rubber distributor -Type: 500 Art. No. 65T0500112P42ZF -Primary: 220V 50Hz -Secondary: 42 V see photo nameplate -Power: 500VA -Dimension.: 320/230/H265 mm -Weight: 12 kg
used
Isolation transformer, isolating transformer RATHGEBER ET 160 ( ET160 ) 0.2 / 0.47 kVA Prim. 230 / 220 / 210 V AC sec. 110 V AC 0.9 / 1.82 A 50 - 60 Hz New ! Dimensions: 110 x 100 x 100 mm
used
Single-phase isolation transformer, isolating transformer, solid rubber distributor -Manufacturer: Gifas, isolating transformer solid rubber distributor -Type: 35T2KVA01ETAESB11103 -Primary/Secondary: 230V 50-60Hz -Power: 2.0kVA -Protection class: IP 54 -Number: 3x transformer available -Price per piece -Dimension.: 360/360/H250 mm -Weight: 26 kg/pc.
used
Isolation transformer, isolating transformer ULMER TRANSFORMATOREN TUE 0.1 ( TUE0.1 ) 0.1 kVA Prim. 220 V AC 0.45 A sec. 50 / 100 V AC 1.0 A 50 - 60 Hz unused ! Dimensions: 100 x 85 x 80 mm
used
PTC thermistor relay, contactor, semiconductor contactor, contactor, relay, isolating amplifier -Manufacturer: Phoenix Contact, Conf. Isolation Amplifier -Type: MCR-FL-C-UI-UI-DCI-24/230 -Number: 2x relays available -Price: per piece -Dimensions: 100/15/H115 mm -Weight: 0.1 kg/piece
used
PTC thermistor relay, contactor, semiconductor contactor, contactor, relay, isolating amplifier -Manufacturer: Phoenix Contact, Conf. Isolation Amplifier -Type: MCR-FL-C-UI-UI-B-DCI-24/230 -Number: 11x relays available -Price: per piece -Dimensions: 100/15/H115 mm -Weight: 0.1 kg/piece
used
Isolation transformer, isolating transformer PGH RADIO and TELEVISION S120Cu/10 P00/A60u 0.12 kVA Prim. 380 V AC sec. 220 V AC 50 Hz used ! Dimensions: 105 x 80 x 130 mm
used
Isolation transformer, isolating transformer PGH RADIO and TELEVISION S25Cu/2 P00/A60u 0,025 kVA Prim. 220 V AC sec. 12 V AC used ! Dimensions: 105 x 80 x 130 mm
used
Isolation transformer, three-phase isolating transformer KWB TRANSFORMATOREN BV:041/0129 16.5 / 15.7 kVA Prim.: 380 - 500 V 3AC sec.1: 60 V 3AC, 29.0 A sec.2: 226 V 3AC, 31.0 A sec.3: 19 V 3AC, 15.2 A sec.4: 28.5 V 3AC, 22.0 A sec.5: 220 V 1AC, 10.0 A 50 - 60 Hz used ! Dimensions: 420 x 390 x 230 mm
used
Isolation transformer BLOCK ETTK1000 1,0 kVA Prim.: 230 V 1AC, 4.9 A sec.: 230 V 1AC, 4.35 A 50 - 60 Hz IP67 Cable length: approx. 1.9 m used, tested ! dimensions ( without cable ): 330 x 140 x 230 mm
used
Isolation transformer, three-phase isolating transformer GETRA BV040392 0,0,667 kVA Primary: 3 x 380 V AC Secondary 1: 3 x 19 V AC, 12 A Secondary 2: 2 x 14 V AC, 10 A 50 / 60 Hz spare part for EDM machine MD PRONTO 5040 !, etc. used ! Dimensions: 180 x 95 x 180 mm
used
Isolation transformer, three-phase isolating transformer GETRA BV64030400471202/A 8,7 kVA Primary: 3 x 380 V AC Secondary 1: 3 x 86 / 108 / 150 V AC, 5 A Secondary 2: 3 x 45 V AC, 95 A 50 / 60 Hz spare part for EDM machine MD PRONTO 5040 ! used ! Dimensions: 360 x 230 x 370 mm
used
Isolation transformer, single-phase transformer, transformer SBA ETK 167-0001 1.6 / 4.24 kVA Primary: 380 / 400 / 420 V 1AC Secondary: 230 V 1AC, 6.96 A 50 / 60 Hz used, tested ! Dimensions: 175 x 155 x 150 mm
used
Mobile isolation transformer GIFAS Type 4000 40T300001N12P42NESBSO Power: 3000 VA Secondary voltage: 230 / 42 V 1AC Primary voltage: 230 V 1AC Cable length: approx. 2.7 m used, tested ! Dimensions ( without cable ): 530 x 400 x 165 mm
used
Mobile isolation transformer, extra-low voltage transformer BÜRKLE & SCHÖCK type CX4073 Power: 400 VA Secondary voltage: 42 V 1AC 9.52 A Primary voltage: 220 V 1AC 1.9 A Cable length: approx. 4.0 m used, tested ! Dimensions ( without cable ): 330 x 280 x 340 mm
used
Mobile isolation transformer SCHEELE-ELEKTRIK Transformer: Type UI 120/51s Power: 1500 VA Secondary voltage: 230 V 1AC 6.52 A Primary voltage: 230 V 1AC 7.14 A IP54 Cable length: approx. 1.7 m used, tested ! dimensions ( without cable ): 390 x 300 x 210 mm
used
Mobile isolation transformer, extra-low voltage transformer GIFAS Type 3000 Transformer: S + B Type UI114/64 Power: 1500 VA Secondary voltage: 42 V 1AC 35.7 A Primary voltage: 220 V 1AC 7.23 A Cable length: approx. 1.5 m used, tested ! Dimensions ( without cable ): 360 x 340 x 220 mm
used
Mobile isolation transformer, extra-low voltage transformer GIFAS Type 6100 Transformer: S+B Type EI 120/73 Power: 500 VA Secondary voltage: 24 V 1AC 20,8 A Primary voltage: 220 V 1AC 2.5 A Cable length: approx. 4.0 m 4x socket type 241629, 16 A, 24 V, 50 - 60 Hz used, tested ! Dimensions ( without cable ): 275 x 195 x 190 mm
used
Mobile isolation transformer, extra-low voltage transformer GIFAS Type 6100 Transformer: ISMET Type T 40/E Power: 250 VA Secondary voltage: 42 V 1AC 5,95 A Primary voltage: 220 V 1AC 1.4 A Cable length: approx. 2.8 m 1x socket type 421629, 16 A, 42 V, 50 - 60 Hz used, tested ! Dimensions ( without cable ): 245 x 190 x 180 mm
used
Mobile isolation transformer, extra-low voltage transformer FRITZSCH GmbH, CEE-ELEKTRO-SYSTEM-BAU Trafo 220V/42V Power: 0,0,16 kW Secondary voltage: 42 V 1AC 3.8 A Primary voltage: 220 V 1AC 50 / 60 Hz Cable length: approx. 2.8 m 1x socket MENNEKES type 604, 16 A - 12h, 50 V, 50 - 60 Hz used, tested ! Dimensions ( without cable ): 155 x 150 x 175 mm
used
Mobile isolation transformer, extra-low voltage transformer, with mains socket GIFAS Type 2516 Power: 100 W Secondary voltage: 24 V 1AC Primary voltage: 220 V 1AC Cable length: approx. 2.8 m 1x socket type 241629.KD 16 A, 24 V, 50 - 60 Hz, 2-pole 1x Mains socket 220 V, 50 - 60 Hz, 3-pole used, tested ! Dimensions ( without cable ): 340 x 75 x 200 mm
used
Mobile isolation transformer, extra-low voltage transformer ISMET Type TSTC Power: 1000 VA Secondary voltage: 42 V 1AC 23.8 A 1x socket BALS CEENorm 32 A, 40 - 50 V, 50 - 60 Hz, 2-pole Primary voltage: 380 V 1AC 6.3 A Cable length: approx. 2.2 m CEE - Plug BALS CEENorm Type 2136, 16 A, 200 - 415 V, 50 - 60 Hz, 5-pin used, tested ! Dimensions ( without cable ): 270 x 200 x 230 mm
used
Mobile isolation transformer, extra-low voltage transformer ISMET type TSTC Power: 400 VA Secondary voltage: 42 V 1AC, 9,, 5 A 1x CEE socket: 32 A - 12 h, 40 - 50 V AC, 2-pole 3x CEE socket: 16 A - 12 h, 42 V AC, 2-pole Primary voltage: 220 V 1AC, 4.0 A Cable length: approx. 2.7 m used, tested ! Dimensions ( without cable ): 270 x 220 x 230 mm
used
Mobile isolation transformer FLEX, ACKERMANN AND SCHMITT Type: TT2602 Power: 2000 VA Primary voltage: 230 V 1AC 10 A Secondary voltage: 230 V 1AC 50 Hz Cable length: approx. 3.8 m used, tested ! Dimensions ( without cable ): 265 x 230 x 265 mm
used
Mobile isolation transformer FLEX, ACKERMANN AND SCHMITT Type: TT2602 Power: 2000 VA Primary voltage: 230 V 1AC 10 A Secondary voltage: 230 V 1AC 50 Hz Cable length: approx. 4.6 m used, tested ! Dimensions ( without cable ): 265 x 230 x 250 mm
used
Mobile isolation transformer, extra-low voltage transformer RTD Transformer: Type VT242 Throttle: Type SMP Power: 630 VA Primary voltage: 220 V 1AC Secondary voltage: 42 V 1AC 7 A 50 Hz Cable length: approx. 4.7 m used, tested ! dimensions ( without cable ): 365 x 200 x 210 mm
used
Mobile isolation transformer, extra-low voltage transformer SCHEELE-ELEKTRIK G 8820 transformer: Type EI 135/62s Power: 500 VA Primary voltage: 230 V 1AC 2,4 A Secondary voltage: 42 V 1AC 11.9 A IP54 Cable length: approx. 1.5 m used, tested ! dimensions ( without cable ): 335 x 260 x 220 mm
used
Mobile isolation transformer, extra-low voltage transformer GIFAS type S11 Power: 300 W Secondary voltage: 42 V 1AC Primary voltage: 220 V Cable length: approx. 3,3,5 m 4x socket type 421629, 16 A, 42 V, 50 - 60 Hz used, tested ! Dimensions ( without cable ): 315 x 230 x 275 mm
used
Mobile isolation transformer, solid rubber distributor, on chassis ELSPRO series NÜRNBERG 3680002/K Power: 4000 VA Primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / primary voltage: 2000 VAbr /br / 30 V 1AC Secondary voltage: 230 V 1AC 16 A 50 - 60 Hz IP54 with thermal circuit breaker: 16 A Cable length: approx. 2.3 m New ! Dimensions: 620 x 460 x 1120 mm
used
Mobile isolation transformer, extra-low voltage transformer PAGUS 300 VA 42 V Power: approx. 300 VA Secondary voltage: 42 V 1AC Primary voltage: 220 V 1AC transformer core ( UI - 90 ): Length: 150 mm, width: 90 mm, thickness: 50 mm Cable length: approx. 1.5 m used, tested ! Dimensions ( without cable ): 300 x 165 x 255 mm
used
Isolation transformer, three-phase isolating transformer M. RIEDEL TRANSFORMATORENBAU RDRKG 40 KM ( RDRKG40KM ) 1,2 kVA Prim. 3 x 230 / 400 - 480 V sec. 24 V DC 40 A 50 - 60 Hz with downstream three-phase bridge rectifier ! Dimensions: 285 x 230 x 210 mm
used
Isolation transformer, single-phase transformer, transformer SBA ETK Art.Nr.: 165-0086 1,0 / 3,624 kVA Primary: 380 / 400 / 420 V 1AC Secondary: 230 V 1AC, 4.35 A 50 / 60 Hz spare part for cylindrical grinding machine NOMOCO VSR5-230-CNC ! used, tested ! Dimensions: 155 x 150 x 135 mm
used
Explosion protection valve VENTEX-ESI-E single-acting, DN200, Type5-A/N/P3 vertical or horizontal installation Passive without control and external energy Approved and certified safety technology from Switzerland
used
Control transformer, control transformer SIEMENS SIDAC T 4AP2595-0BA00-8A 6.3 kVA Prim. 500 V 3AC sec. 380 V 3AC 50 - 60 Hz unused ! Dimensions: 230 x 130 x 210 mm
used
Pure C-810 / C-815 Flash are advanced, powerful flash systems which allow more purification in less space thanks to their compact design. They ensure safety on the highest level and can be operated outside of a fume hood, as they are equipped with a closed fraction collector bay. Also, they are furnished with leak and pressure sensors as well as with a remote control to reduce exposure to the lab environment. Pure C-815 is additionally equipped with integrated ELSD that is dedicated to flash chromatography and exhibits the lowest sample loss in the market. The Pure Chromatography Line by Buchi Labortechnik AG embodies flash and prep HPLC instruments in one system, easy to use for any flash or prep HPLC application. Typical Applications: Purification after synthesis, preparative isolation of a compound from a formulation, purification of APIs after organic synthesis, screening o ...
new
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mo ...
new
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C170 D5 Enclosed A047W024 Genset Model C170 D5, 170kVA Standby, 155kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G7 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...