We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
121,912 used machines on RESALE, but how to find them? Machine Search
maximum number of results exceeded > 1000
please refine your search
used
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protection Class: IPX4 Dimensions: Depth mm 550, width mm 1420, height mm 1288 Weight kg 197 Connection Rp 1" Serial No.: 2200371602 Year of construction: 2021 Condition: Optical 2, Technically ok us ...
used
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protection Class: IPX4 Dimensions: Depth mm 550, width mm 1420, height mm 1288 Weight kg 197 Connection Rp 1" Serial No.: 2200371602 Year of construction: 2021 Condition: Optical 2, Technically ok us ...
new
Variable area flow meter for heat transfer oil, H250/RR/M40/HAT/ESK, Krohne, new -60% Special price ! The current price of a similar product is about € 2100 excluding VAT. If you have a UID number, we will gladly issue an invoice without VAT. We still have several identical units, but the quantity is ending. Buy more than 1 piece there is still a great discount. As good as new in original packaging! The part was bought from a spare parts store of a company and has never been in operation, is completely as new and in the original packaging. Technical data: - For heat transfer oil with 860 kg/m³. - Viscosity 1.23 mm²/s - Working temperature: 200°C - Working pressure: 5,0 bar - Measuring range 0-25 l/min - Connection G1 - Output signal 4 - 20mA - Made of stainless steel 316 - Max. working pressure: 70 bar - Max. Temperature: 300°C Function guarantee! For sec ...
new
Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 24 Max. current (A) 40 Starting current circuit (A) 162 Protection class: IP22 Dimensions: Length mm 1735, Width mm 660, Height mm 120 ...
new
Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 24 Max. current (A) 40 Starting current circuit (A) 162 Protection class: IP22 Dimensions: Length mm 1735, Width mm 660, Height mm 120 ...
new
Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5.4 Max. current (A) 9.7 Starting current circuit (A) 44.5 Protection class: IPX4 Dimensions: Depth mm 1404, Width mm 580, Height mm 1293 Weight kg 273 Conn ...
new
Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5.4 Max. current (A) 9.7 Starting current circuit (A) 44.5 Protection class: IPX4 Dimensions: Depth mm 1404, Width mm 580, Height mm 1293 Weight kg 273 Conn ...
new
APV HEAT EXCHANGER BRM8, CODE NO: 18950015, TYPE:U229R BERGEN BRM, WARTSILA, DEUTZ KHD/MWM, MAN B&W, JENBACHER, ABC, PIELSTICK , GUASCOR, MAK, CATERPILLAR, VOLVO, WICHMANN, PUMPS, SACM, SEPARATOR, COMPRESSSOR, FILTER, PUMPS, VACUUM SAVAGE SYSTEM, HEAT EXCHANGER & COOLER. Spares are available and all kinds of spare parts can be given. Please contact us for your questions. EVE International AS E-Mail : info@eveinternational.com.tr Phone : +90 0216 519 2707 Fax : +90 0216 519 2720
used
Electric heat exchanger, swimming pool heating, heat exchanger -400 VAC 26.0 A -Pressure: max. 3 bar -Dimensions: 980/180/H180 mm -Weight: 3.1 kg
used
Ceiling air heater, heat exchanger ILKA, MASCHINENFABRIK Nema type P12 TGL 180-1100 Operating pressure: max. 19 kp/cm² ( approx. 19 bar ) Heat exchanger: 410 x 340 x 115 mm Connection diameter ( inside / outside ): Ø 27 / 34 mm without fan Material: Steel, galvanized, painted New ! Dimensions: 500 x 310 x 440 mm
used
Ceiling air heater, heat exchanger, with fan ILKA, MASCHINENFABRIK Nema type P20 TGL 180-1100 Operating pressure: max. 19 kp/cm² ( approx. 19 bar ) Heat exchanger: 550 x 450 x 190 mm Connection diameter ( inside / outside ): Ø 27 / 34 mm Fan: Impeller: Ø 240 mm Motor: VEM KMO 56 G 6 0,12 kW 870 rpm 220 / 380 V 3AC 50 Hz IP44 Material: Steel, galvanized New, with underlays ! Dimensions: 850 x 460 x 560 mm
used
Manufacturer: Solev (Clauger) Model: RH 550/230-25U-0-RS-SP-2G/1F Year : 2007 Type : glycol water heat controller / Thermal skid Class : ATEX - EX II 3 G - EEx b,c,d,e II B T2 Minimum / maximum temperature : +20?C / +230?C Intensity: 51 A. Heating: 25 kW immersion heater Heating control by thyristors. Cooling: No cooling system. Heat transfer fluid: Therminol 66 Regulator type 2704 single loop from EUROTHERM Centrifugal electric pump unit giving a flow rate of 26 m3/H Motor: 4 KW. ALWEILLER NBT32-160/01/149 pump Filling volume : 69 L - 246 L Documentation available Sold with protective cover.
used
Heat exchanger, cooling coil, cooling pipe, cooling spiral -Heat exchanger: cooling coil with fins -Dimensions: see photos -Transport dimension: Ø60 x 290 mm -Weight: 0.4 kg
used
Heat exchanger, cooling coil, cooling pipe, cooling spiral -Heat exchanger: cooling coil with fins -Dimensions: see photos -Transport dimension: Ø65 x 365 mm -Weight: 0.5 kg
used
Key data: 537 , 400
Pro2 container unit with 537kW el. Performance as a pure power generator incl. heat recovery system - 40 ft normal container (L x W x H in metres) 12.2 x 2.55 x 2.55 metres with lighting - MWM genset TCG2016V12 - 537kW for landfill gas, biogas or natural gas with gas control system and control cabinets for plant control, auxiliary drive supply and GLF - Current operation hours about 87,000 - Soundproofed design as a plant container - Separation of containers into engine room / electrical room with connecting door - Access door to the engine room on the longitudinal side and electrical room on the front side - Gas detector and smoke detector - Supply and exhaust air system with backdrop silencer and supply air filtration - Engine cooling water circuit with circulation pump, warm-up control via 3-way mixer - Emergency cooling for HT circuit integrated into the engine cooling wat ...
used
Pro2 container unit with 311kW el. Performance as a pure power generator - 40 ft normal container (L x W x H in metres) 12.2 x 2.55 x 2.55 metres with lighting - MWM genset TBG 616V8K - 311kW for landfill gas, biogas or natural gas with gas control system and control cabinets for plant control, auxiliary drive supply and GLF - Current bra number only about 95,000 - Soundproofed design as a plant container - Separation of containers into engine room / electrical room with connecting door - Access door to the engine room on the longitudinal side and electrical room on the front side - Gas detector and smoke detector - Supply and exhaust air system with backdrop silencer and supply air filtration - Engine cooling water circuit with circulation pump, warm-up control via 3-way mixer - Emergency cooling for HT circuit integrated into the engine cooling water circuit, designed for th ...
new
Carbolite Gero AX120 Heating Oven Original price 4561 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 128 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 26 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 495 x 500 x 520 External dimensions H x W x D (mm) 640 x 790 x 665 Load per grid/total 10/40(kg) Air change per h 14 Max. power (W) 2000 Holding pow ...
new
Carbolite Gero AX60 Heating Oven Original price 3844 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 66 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 25 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 395 x 400 x 420 External dimensions H x W x D (mm) 540 x 690 x 565 Load per grid/total 10/30 (kg) Air change per h 28 Max. power (W) 1500 Holding powe ...
new
Carbolite Gero AX30 Heating Oven Original price 3185 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. The tabletop units are equipped with R38 PID controllers as standard. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 1000 Holding power ...
new
Carbolite Gero AX30 Heating Oven Original price 3385 € Heating cabinets of the Apex AX series are economy laboratory devices for temperatures up to 250°C. Digital PID Controller R38 Recirculating air fan for short heat-up times and excellent temperature homogeneity Stainless steel inner chamber Two height-adjustable, chrome-plated lattice shelves Door with locking function and airtight silicone gasket Complies with safety standard BS EN 61010-2-010:2003 Maximum temperature 250°C Minimum temperature RT + 30°C Volume (litres) 28 Temperature homogeneity (°C) ±5.0 250°C Heat-up time (min) 23 Recovery Time (min) 3 Dimensions: Inside H x W x D (mm) 295 x 300 x 320 External dimensions H x W x D (mm) 440 x 590 x 465 Load per grid/total 10/20(kg) Air change per h 65 Max. power (W) 918 Holding power (W) 342 Weight (kg) 24 Condition: new, without original packaging ...
used
Schräder AWT-BP Exhaust Gas Heat Exchanger Year: 2015 Schräder AWT-BP Exhaust Gas Heat Exchanger with Internal Bypass Type: AWT - BP 20-650 8 S 10 R303 R Year of construction: 2015
new
Heat pump / chiller air-cooled, Type: Taurus TECH HTAT 040 HE MTA S.p.A. Heat pump / chiller Taurus TECH HTAT 040 HE (reversible) with hydronic kit, storage tank + pump P15 + fairing hydraulics. Heating capacity kW 99.3 Cold water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 17.2 Available pump pressure bar 0.966 Ambient temperature +7 °C Cooling capacity kW 84.5 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 14.4 Available pump pressure bar 1.24 Ambient temperature 32 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 47 Max. current (A) 79 Starting current circuit (A) 263 Protection class: IP54 Dimensions: Length mm 2510, Width mm 1110, Height mm 2270 Weight kg 1113 Connection Rp 2" Serial No.: 2200392018 Year of construction 2022 Condition: Optical 1, Technically ok (Stock ...
used
Automatic multiple heat sealing dispenser For packaging and heat sealing 8 jars simultaneously. Production capacity 16 u/min Includes 8-spout DOSITERM dispenser and BUSCH vacuum pump model RA0160 D 561 XXX1 Delivered with a set of 8 x 1 molds (installed) and another set of 6 x 1 molds DOCUMENTATION AVAILABLE
used
Natural gas CHP MAN E2876 E312 Power el.: 143 kW Power th.: 205 kW 6 cylinders Commissioning: 2017 Hours: 44650 Full maintenance by AVS Aggregate has been preserved Generator: Manufacturer: FKI - Type: MJB250LB/4 - 158/188 kVA Soundproofing hood 2x heat exchanger and heat accumulator 2x 5000 liters Unit certificate is available. Subject to prior sale - errors possible Internal Reference Number: E-1175
used
Schroeder-Combinator / scraped surface heat exchanger technical details: capacity/ flow rate: 20-100 ltr/h against 12 bar engine power: 3,5 KW dimensions: length x with x higth : 170 x 43 x 85 cm weight ca.: 150 kg with this device you can go with: hight viscosity and lumpy food for heating, cooling, mixing and pumping
used
Material: Stainless steel Built: 1993 Content: 1770 ltr Pressure inside: 0.5bar Pressure outside: 10bar Weight: 5000 kg L x W x H: 4700mm/900mm/1200mm An indirect heat exchanger with mechanical material transport. Very good condition. YOU ARE A NEW, OUTDATED AND USED
used
Used ceiling heater,Ideal for workshops Heat output:90/70-15C 39.5 KW Electrical voltage 1by230V Air volume flow:4640m3/pc. Speed 1330rpm Max feed temperature130C Max operating pressure 11 bar Weight 43Kg
used
Heating with hot water and heat exchanger. Air filter and Verteilkänäle. Type I engine number 918005 0720.25.20
used
Full stainless steel heat exchanger in round shape. Previous use: heating air with steam. Suitable for heating or cooling aggressive gases/air.
used
VA Tube Bundle WT Manufacturer: E. Gessner AG, built 1982, material 1.4465, 1.4571, Dimensions: Diameter Coat: 600mm Effective Length Pipes: 5000mm Di-inner tube: 20mm Da inner tube: 24mm Total length 5880mm Total height: 1000mm Connections Coat: DN 200 Connections Pipe side DN 50 Foot distance (holes) 3000mm Transmission area: 65m2 / 78m2 (indoor/outdoor) 208 inner tubes Ab. Pressures: -1 / 3 bar inner tubes -1 / 6bar coat Temp range: -10 / +200 Price refers to a heat exchanger. 2 present
used
ELCO econom 2000 heating system Hall heating Air conditioning Wolf Type/serial No. 100-2 9201 Motor power 1 .1kw Nominal current 5.2/3,0A Voltage 380V Mot.Drehzahl 1500min Heat output of 63kW Air flow 5000 m³/h p.ext. 25Pa Ã?ldurchs. 6, 0 kg/h DIN-DVGW 90.03 f where Functionality is not known, the device is offered as a spare part supplier. Can the proper dismantling and pick-up at the location The iron bridge 16, 65795 Hattersheim be made. We are happy to answer questions phone 06190-93449-0 The complex can be visited by appointment. Price VB, make an offer. -> Note Please also our other ads < -. We can offer you several thousand square metres of used formwork, scaffolding and tools - ask us! (SoPo 411)
used
heat holder - Alfa Laval - technical data (see also:) 750 litre/h Content: 7.31 ltr. average length: 19371 mm Diameter: 22 mm
used
Type: UTK 18 200-2a-2e Power: 2 X 11 kW + 1 X 7.5 of kW, 380 V, 50 Hz Perslucht: max 20-25 bar Weight: 4,000 kg YOM 1985 Scraped surface heat exchanger for heating, temperature holding and cooling of liquid, vegetable, high viscous and crystalline products. Previous used for heating, holding (volume ± 85 ltr) and with steam cooling of food products (sauces) and ammonia (NH3, 125 ltr., 17 bar,-20 ° C / 45 ° C). 2 independent ammonia system. Constant quality of the product, continuous running and inline cleaning system (CIP).
used
FOR SALE NEW UNUSED 4 PCS ALFA LAVAL HEAT PAC EHM 40KW TO WHOM IT MAY CONCERN ; WE VE 4 PCS-NEW UNUSED ALFA LAVAL HEATPAC EHM 40KW AT OUR STOCK. HEATPAC IS 440V YOB 2013 PLS FIND SPECT AT PICTURES IF YOU'VE ANY FURTHER QUESTIONS PLS DO NOT HESITATE TO CONTACT WITH US. Capt. Ayhan Ugurluba Best regards; Aliaga marine services E mail: info/aliagamarine.com PHN/fax: +90 232 618 03 90 Mobile: + 905556084850 aliagamarine.com TURKEY
used
Tube bundle heat exchangers Manufacturer: Orsymonde France Type: Tube bundle Year of construction: 2000 Serial number: 1.00.098 Carrier: Medium: Water Material: 1.4404 (V4A) Operating pressure: 3 bar Temperature: ambient temperature Test pressure: 6 bar Coat: Medium: Gas Material: 1.4404 (V4A) Operating pressure: 0.5 bar Temperature: ambient temperature Test pressure: 1 bar Dimensions: Length: 2.070 mm Width: 1.070 mm In very good condition!
new
Furnace 1200 working temperature 100 - 1200 Celsius size 1x1x2m auto door auto bogie Verkäufe Drehmaschinen Fräsmaschinen Bohrmaschinen Schleifmaschinen Erodiermaschinen Sonstige Maschinen Kaufgesuche Drehmaschinen Fräsmaschinen Bohrmaschinen Schleifmasc inen Erodiermaschinen Sonstige Maschinen Keramik-, Porzellan- und Smaltenherstellung und -bearbeitung Glasherstellung und Glasverarbeitung Smaltenherste lung und -bearbeitung Labors / Zahnärzte/ Schmuckherstellung Buntmetallgie ßereien Stahlwarmbehandlung Warmbehandlung von dem Aluminium und dessen Legierungen Warmbehandlung von anderen Metallen Kunststoffwarmbehandlung Gummi- und K autschukwarmbehandlung Polyuretanwarmbehandlung Aushärtung vo n den Kompositmaterialien Trocknung der Schweißelektroden Formierprozess der Elektroelemente Wärmbehandlung bei Oberflächenbehandlungen Poreba Gurutzpe Tacchi Gem ...
used
Stock number: UG6204 Second hand, refurbished, stainless steel plate heat exchanger by Alfa Laval type CLIP 6-RH (C6). Plates designed in stainless steel AISI 316L. Working volume 68.2 l. Working pressure 16 bar, test pressure 21 bar. Working temperature in range from 0 up to 110 C. Connections are DIN 11851 DN50. Exchanger is mounted on stainless steel frame. Gaskets designed in NBR, mounted without a glue, type clip-on. Unit is cleaned and leak tested. Last time used on food. Includes stainless steel covers.
used
Heat exchanging type: VES 8''SX 1 FV minimum temperature: -10 St C pressure: 18 bar not used
used
GEA Canzler spiral heat exchangers with milk pipe fitting on the input and output, Operating pressure:-1 to 6 bar Operating temperature:-10 to 200 C ° Volume: 32 liters Area: 10 m2 Number of screws: 12 Empty weight: 400 kg
Standard scope of delivery â?¢ 12 cylinder four-stroke gas engine in V-arrangement based on MAN diesel engine single-cylinder heads, high-alloy valve seat rings and valves, form-forged crankshaft with screwed counterweights, wet cylinder jacks, piston cooling over oil spray nozzles â?¢ Compression ratio 14:1, biogas 1500 rpm â?¢ Main power oil filter, 2-fold, reclining, not switchable with oil cooler â?¢ Closed crankcase ventilation with oil separator â?¢ Flywheel case SAE 1 â?¢ Flywheel I = 2.292 kgm2 for clutch SAE 11.5 and SAE 14 with tooth wreath â?¢ Anlassser â?¢ Valve solvets made of hard metal â?¢ Cam shaft with drive wheel for electric ignition equipment â?¢ Exhaust collection mammals line uncooled, isolated â?¢ Exhaust turbochargers water-cooled, ...
new
MTU 8V396 TB 53 Heat Exchangers Charge Air Coolers Intercoolers 2930-12-334-9601 / 0010985920
new
MTU 8V396 TB 53 Heat Exchangers Charge Air Coolers Intercoolers 2930-12-334-9277 / 0052000675
new
MTU 16V4000 M 90 A BANK Heat Exchangers Charge Air Coolers Intercoolers 2930-12-378-7717 5260981120
new
MTU 16V4000 M 90 B BANK Heat Exchangers Charge Air Coolers Intercoolers 2930-12-378-7720 5260981120
new
JENBACHER TYPE 4 Heat Exchangers Charge Air Coolers Intercoolers J414 / J416 / J420 PNo:1202340
new
GUSCOR HGM560 / SFGLD560 Heat Exchangers Charge Air Coolers Intercoolers Part Number 7673532
new
JENBACHER TYPE 3 Heat Exchangers Charge Air Coolers Intercoolers 6141424 / 1212197 / 369829
new
MWM TCG 2020 V12/V16/V20 Heat Exchangers Charge Air Coolers Intercoolers Part Number 12452511
used
used
Stainless steel tube bundle heat exchanger Coat and pipes made of 1.4571 Power 600 kW 7,400 litres of water from 10 °C to 80 °C at 8 bar saturated steam and 90 °C condensate temperature To the pipes: Pressure 13 bar Operating temperature 200 °C Content 33 litres In the pipes: Pressure 10 bar Operating temperature 120 °C Content 18 litres