11 offers cogeneration

Category: 1107 other energy machinery
Latest update: 20.09.2019 add to watchlist
approved
dealer
item-No.: 136151004
New in: 2007

used

check Seller: GE-TRA-MACK
Location: CHIARI (BS) Land-it

add to watchlist

WARTSILA COGENERATION PLANT YEAR: 2007 POWER OUTPUT: 1.50 MW

Category: 1107 other energy machinery
Latest update: 04.03.2024 add to watchlist
approved
dealer
item-No.: 161297187
New in: 2013

used

check Seller: Perry Machinery Poland
Location: Land-pl

add to watchlist

Stock # UG6358 Used cogeneration plant by Caterpillar working on natural gase. Consist of two motors type G3516C, each with power 1.2 MW. Total power 2.4 MW.

Category: 1107 other energy machinery
Latest update: 17.04.2024 add to watchlist
approved
dealer
item-No.: 163837852
New in: 2012

used

check Seller: Surplex GmbH
Location: Vallemare (PE) Land-it

add to watchlist

Description: Cogeneration plant for the electricity production from renewable sources The machine was created to be fueled with vegetable oils of rapeseed, sunflower and soybean oil, but thanks to the complex heated introduction system, it can burn animal fats and palm oil. The hourly production of electricity is equal to 940 kw/h The machinery is composed of: power source ,with fuel heating before combustion (underground tanks excluded) WÄRTSILÄ NSD 6R22/26 engine, produced in 1999 with a power of 1,065 kw at 1,000 rpm (power reduced to 940 kw/h to comply with authorisations) alternator DENOX system control panel catalytic silencer with cover and chimney chiller for cooling and heating systems hot water generation system with heat exchanger for powering warehouse heating systems transformer room ,with control panels, Landis+Gyr E650 meter, MESSINA SVT/R+AC/R medium  ...

Category: 1107 other energy machinery
Latest update: 06.07.2023 add to watchlist
approved
dealer
item-No.: 6264797

used

check Seller: REWA Gruppe - REWA KFP GmbH
Location: Gladbeck Land-de

add to watchlist

Heat exchanger for cogeneration block cogeneration with 250 kVA 2 x available

Category: 1101 power generators
Latest update: 02.03.2024 add to watchlist
approved
dealer
item-No.: 7187600
New in: 1996

used

check Seller: BA-Generatoren
Location: Land-de

add to watchlist

We offer two Ford gas cogeneration plants for sale. Synchronous generator: Emod 19 KVA Engine: Ford Voltage: 230 / 400 3 phases Frequency: 50 Hz Speed: 1500 rpm COS phi: 0.8 Starter: 24 V Weight: 900 kg Year of construction: 1996 Hours of operation: 24,000

Category: 1101 power generators
Latest update: 02.03.2024 add to watchlist
approved
dealer
item-No.: 7576274
New in: 1993

used

check Seller: BA-Generatoren
Location: Land-de

add to watchlist

We offer for sale 2 Jenbacher cogeneration plants, type: JW312GSB. Motors are of the manufacturer of Stamford. Performance: 675 KVA. Both units are complete. One is easily broken. Hours of operation: approx. 55000 and 28000 At the operational unit, the generator was replaced and overhauled.

Category: 1101 power generators / Block combined heat and power stations
Latest update: 30.09.2020 add to watchlist
approved
dealer
ankerimg
item-No.: 60205742

used

check Seller: KWK Service GmbH
Location: Land-de
Price: 3.000 € add to watchlist

We sell a used natural gas cogeneration manufacturer spilling, type power Therm with an electrical output of 20 kW.

Category: 1101 power generators / Gas generators
Latest update: 20.03.2024 add to watchlist
approved
dealer
item-No.: 163316111
New in: 2023

used

check Seller: Gas Engine Exchange Ltd
Location: Land-uk
Price: 285.000 € add to watchlist

Key data: 999 , 400

4 x MTU 8V4000 GS MIP + MMC. Series 4000 four-stroke turbocharged gas engine with mixture cooling - compact, high performance, reliable, maintenance-friendly and extremely economical. Lean mixture technology, state-of-the-art electronic ignition system with individual ignition timing and automatic ignition power control, anti-knock control as well as highly responsive mixture and load control ensure economical and safe genset operation with optimum use of the energy input. Island operation capability. Make and Model: MTU 8V4000 GS MIP Capacity: 999kW Hours: 0 Year: 2023 Fuel: Natural Gas V: 400 HZ: 50 Scope of supply: Engine, Alternator (Stamford), Base frame, MIP (MTU Interface Panel), MMC (MTU Module Control - The MMC contains the cogeneration control system including mains monitoring, visualization and user interface). Price: €285,000 each Please note:  ...

Category: 2100 electrical parts
Latest update: 19.10.2023 add to watchlist
approved
dealer
item-No.: 161381143

used

check Seller: Hinrich Goltz & Söhne GmbH
Location: 21129 Hamburg Land-de
VS

add to watchlist

Lean emission controller for gas engines with cogeneration units, Motortech EMCon5 for sale, with original packaging

Category: 1101 power generators / Block combined heat and power stations
Latest update: 29.03.2024 add to watchlist
item-No.: 163393931
New in: 1995

used

Seller: Plant Industrial Engineering Kft.
Location: Land-dk

add to watchlist

Engine type: 18V34SG Electrical power output: 5500kWe, 6838kVA Engine speed, direction: 750rpm, CW Generator type: ABB HSG 900XS8, 15kV, 50Hz Engine control system: WECS 3000 Turbocharger: Napier NA 355 Fuel: Natural gas Application mode: Cogeneration power plant Year: 1995 Running hours: 54855 h Running hours since last overhaul (48721rhs, 05.2010) 6131 h Next major overhaul: 64000 h Original installation: Denmark Genset condition: Excellent Stopped: 08.2022 Service history and documentation: Available Location: Denmark (will be in Hungary 2024 Q2) Scope of supply: Genset Heat recovery Gasramp Silencer lube oil tank Starting air compressor and vessel

Category: 1101 power generators / Gas generators
Latest update: 28.02.2024 add to watchlist
item-No.: 163466361
New in: 2011

used

Seller: JADE Trading Group
Location: 00540 Helsinki Land-fi

add to watchlist

CHP Power Plant 800 kWe with 2xMWM TCG 2016V08 Gas Gensets Good condition and low operating hour 800 kWe / 400 V / 50 Hz combined heat and power (CHP) plant running on natural gas or biogas. The plant was delivered by MWM in 2011 and it operation was closed in 2021. Thermal energy is in form of hot water at 90°C and currently used for district heating purpose. Due to the low amount of biogas, cogeneration plant worked at low capacity (30-40%), and not around the clock. It has a complete gas treatment and mixing system to utilize biogas from landfilling which has 40 – 55 % of CH4. Power generators are installed in two soundproof containers, TEAM Evo WMW power plant control system and all electric switches and control cabinets are installed in separate control room. Heat recovery system is built next to genset containers. Both units have separate cooling radiators for engine cooling ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)
Banner ad information  
RESALE used machinery 25 years online