We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
used
20153 CUMMINS 6 CTA 8.3GM 163 kW MARINE DIESEL ENGINE GENERATOR TURBOCHARGED AND AFTERCOOLED WATER COOLED YES- 24 VOLT BRAND NEW SPECIFIC FEATURES Panel INCLUDED Raw water pump INCLUDED Expansion tank INCLUDED DIMENSIONS LxWxH (cm) Weight (kg) 1200mm x 800mm x 1350mm 1300 KG
used
used
BHKW in container with Cummins diesel engine Lorey Somer generator 250KVA 1500U / min 50 hertz Storm Steuerung, arrangement is equipped with emergency cooler zusaetzl. regularly waited to zeit 21000 company hours. arrangement is operational and available immediately. for other questions I stand to them to verfuegung under 01727265324
new
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C170 D5 Enclosed A047W024 Genset Model C170 D5, 170kVA Standby, 155kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G7 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
NEW injection pump 0402066725(= PES6P110A120RS3336-1) Contact= MIW GmbH Motoren-Instandsetzungs-Werk Nord-West-Ring 8 D-27404 Zeven/Germany phone: 0049(0)4281-950583 fax : 0049(0)4281-950585 info@miw-zeven.de abc.miw-zeven
used
New injection pump 0402 066 725(=PES6P110A120RS3336-1) NET 2.950,-EURO 6 x new injectors 0432 191 342 (Cummins # 408931500) net / piece 215,-EURO Mail: info@miw-zeven
new
C175 D5e Enclosed A049J778 Genset Model C175 D5e, 175kVA Standby, 160kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Wat ...
used
new
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mo ...
new
C200 D5e Enclosed A049J779 Genset Model C200 D5e, 200kVA Standby, 182kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274H, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% W ...
new
C275 D5 Enclosed A049K225 Genset Model C275 D5, 275kVA Standby, 250kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UCD274K, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
new
C330 D5 enclosed A048T878 Genset Model C330 D5, 330kVA Standby, 300kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC4D, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
new
C350 D5 Open A019J715 Genset Model C350 D5, 350kVA Standby, 320kVA Prime, NT855G6, Diesel, Open Emergency Standby Power (ESP) Emission Level; No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NT855G6 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4E, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole, End ...
new
C400 D5 Open A019J729 Genset Model C400 D5, 400kVA Standby, 360kVA Prime, NTA855G4, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G4 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4F, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole ...
new
C400 D5e Enclosed A029Z631 Genset Model C400 D5e, 400kVA Standby, 364kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC4F,50Hz,12 Leads,190 - 220V & 380 - 440V125C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 630A,690V IEC, 600V UL,4 P ...
new
C440 D5 Open A019J736 Genset Model C440 D5, 440kVA Standby, 400kVA Prime, NTA855G7, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G7 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HC5C, 50Hz, 12 Leads, 380-415V, 150C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 800A, 690V IEC, 600V UL, 4P ...
new
C500 D5 Enclosed Genset Model Item C500 D5, 500kVA Standby, 455kVA Prime, 0, 0, QSZ13G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SII Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSZ13G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC5C, 12 Leads, 50 Hertz (Hz), 190 - 220V and 380 - 440V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclo ...
new
C550 D5e Enclosed A029Z751 Genset Model C550 D5e, 550kVA Standby, 500kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC5D,50Hz,12 Leads,200V & 400V150C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 800A,690V IEC, 600V UL,4 Pole,100%,Left C ...
used
MARINE DIESEL ENGINE Reference number 20112 Brand CUMMINS Model KTA19-M600 Power 600 HP RPM 1800 PEAK TORQUE 1950N.m @1500r/min General condition RUNNER Status AVAILABLE SPECIFIC INFORMATION Flywheel housing SAE 0 Flywheel INCLUDED WITH FLEXIBLE COUPLING Governor MECHANICAL Exhaust system WET Turbo TURBOCHARGED AND AFTERCOOLED Cooling system WATER COOLED Starter YES- 24 VOLT Remarks RUNNING ENGINE SPECIFIC FEATURES Panel NO - CAN BE DELVIERED EXTRA Raw water pump INCLUDED Expansion tank INCLUDED Heat exchanger INCLUDED DIMENSIONS LxWxH (cm) 2450mm x 1150mm x 2000mm Weight (kg) APPROX 2700 KGT
used
Cummins KTA38 M2 Building year 2007 with only 35000 hours STD crankshaft power is 1300 HP @1800 rpm
used
Many thanks for your interest in our machinery, please find below our offer: Combined heat and power plant (CHPU)with up to 500KW A total of 3 independent cogenerators with combined heat and power; Electricity & hot water With only max 13280 operation hours!!! Operation is done with heating oil !!! Permission available Total power approx. 500kw, cascade connection, in depending on power requirements, the various energy producers gradually switch on and regulate themselves on the performance. At peak load, all 3 systems work in parallel with full output Ideal for power supply in remote areas without public supply or as emergency power supply with simultaneous heat recovery if desired. Each engine has a heat exchanger. If heat is not needed, it can also be removed. The plant is constructed and ready, accordingly control etc. Top maintained. Spare parts for maintenance etc ...
used
CUMMINS MARINE GENSET 6BT5.9 1M 92 KW 1500 RPM - SN 87381266 -MAGNA PLUS DYNAMO MP-75-4 Reference number 20014 Brand generator CUMMINS/MAGNA PLUS Model generator 6BT5,9 RPM 1500 Serial number 87381266 General condition EXCELLENT NEW CONDITION Status AVAILABLE GENERATOR Brand generator MAGNA PLUS Model generator MP-75-4 Kva 93,8 Serial number generator 36229 Voltage 400 Frequency 50 Phase 3 SPECIFIC INFORMATION Governor N/A Starter N/A Exhaust system N/A Turbo YES Cooling system SEAWATER PUMP/HEADER TANK SPECIFIC FEATURES Panel YES Expansion tank YES Radiator NO Skid YES Soundproof box NO Weight (kg) 600 KG
used
Used Cummins KTA38 M2 engines building year 2007 with working hours 35000 hours
used
Reference number Brand Model Power 20152 CUMMINS KTA19-M3 600 HP 1800 RPM PEAK TORQUE 2374N.m @1800r/min BRAND NEW AVAILABLE SPECIFIC INFORMATION Flywheel housing Flywheel Governor Exhaust system Turbo Cooling system Starter Remarks Sae-0, Sae-1 18 inch, 14 inch MECHANICAL WET TURBOCHARGED AND AFTERCOOLED WATER COOLED YES- 24 VOLT BRAND NEW SPECIFIC FEATURES Panel INCLUDED Raw water pump INCLUDED Expansion tank INCLUDED Heat exchanger INCLUDED DIMENSIONS LxWxH (cm) Weight (kg) 2450mm x 1150mm x 2000mm