We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
used
NATURAL GAS THERMAL POWER PLANT CONSISTING OF 3 CUMMINS 1750GQPB GENERATOR SETS (QSV91-G ENGINE) Fully equipped natural gas thermal power plant. 01 CUMMINS manufactured generator set, Gas, model 1750GQPB (E02K251030), comprising Cummins QSV91-G Engine (66300362) and PCS; with 7695 operating hours. 01 CUMMINS manufactured generator set, Gas, model 1750GQPB (E02K251410), comprising Cummins QSV91-G Engine (66300363) and PCS; with 8746 operating hours. 01 CUMMINS manufactured generator set, Gas, model 1750GQPB (E02K251420), comprising Cummins QSV91-G Engine (66300359) and PCS; with 8061 operating hours. Electrical panels and controls for the respective equipment; DMC 300 (paralleling equipment); QTA (Automatic Transfer Switch); Noise attenuators; 02 Water towers, pumps, and associated cooling system pipes; 01 small transformer, switches, and cable trays; Maintenance switches and ...
used
Key data: 1487 KW
CUMMINS GQSK60 Gas Generator – In Excellent Condition! Looking for a reliable, powerful, and immediately available gas generator? The CUMMINS GQSK60 is the perfect choice for your needs. This generator is in excellent condition and has low operating hours. CUMMINS GQSK60: Excellent condition Low operating hours: Enjoy efficient operation with plenty of potential for many years of trouble-free use. Immediately available: No long wait times Fully equipped: The generator comes complete and ready for installation, including the control panel, breaker, gas line, exhaust silencer, and cooling system. Simply connect the gas and power supply. GAS POWER HOLLAND
used
Forty two (42) Quality Used Cummins/Aggreko NCH20-QSK60G22, Dual Frequency 1875 kVA, 480v. 60 Hz. or 1875 kVA, 400v. 50 Hz. Natural gas generator sets. These 1875 kVA units are set for continuous an parallel to gird IPP applications. These units have less than 5000 hours of use since new. The generator is a gas engine driven alternator with control electronics, mounted on a bedplate and housed within a custom-built 20ft stackable container. The standard package is composed of the following: Alternator and engine assembly, Pressurized oil system, Automated control system, Instrumentation, Safety provisions, Engine cooler pack, Silencer, Gas lines including external Low Pressure Gas Train & internal Solenoid Valve The engine and alternator are integrally mounted. This assembly is isolated from the bedplate base by rubber isolation mounts. A 20ft containerised Gas Cooling Module (G ...
used
Key data: 2000 KW, 2500 kVA, 400 V
2MW Cummins QSV91 available complete with control panel, gas line, heat exchanger, log books and maintenance manuals etc.
used
Key data: 20000 KW, 2500 kVA, 10500 V
2X CUMMINS QSV 91G running hours 61000 year 2006
used
Key data: 1400 KW, 400 V
Cummins QSK60-G10 Natural Gas CHP Generator Set Engine: Cummins QSK60-G10 Complete package: CG1400-GZ Frequency: 50hz Scope of supply: Complete PLUG AND PLAY genset with Engine, alternator, skid, gas line, switchgear, control panel Comap InteliVision 8, gas heat exchanger, container. Available for sale from Gas Engine Exchange . Please check our complete range of equipment at gasengineexchange.com.
new
Key data: 600 KW, 750 kVA, 230 V
2 x 300 kW Cummins Natural Gas Gensets in Soundproof Container, 600 kW Total, Steam Heat Recovery For sale: containerized natural gas power generation package consisting of 2 x 300 kW Cummins gas gensets installed in one soundproof container, including synchronization system for parallel operation and steam-type exhaust gas heat recovery system. Total electrical output in parallel operation: 600 kW. Offered manufacturer package is based on Cummins 15NG-330 gas engines, Leroy-Somer alternators, Woodward ignition/speed control, and DEIF AGC150 controller. Main technical data Quantity: 2 units Rated power: 300 kW each Total power in parallel: 600 kW Fuel: Natural gas Engine: Cummins 15NG-330 Engine rated power: 330 kW Cylinders: 6 Displacement: 14.5 L Rated speed: 1500 rpm Alternator: Leroy-Somer TAL-A46-H Voltage: 230/400 V Frequency: 50 Hz Powe ...
new
Key data: 400 KW, 500 kVA, 230 V
New CUMMINS gas generator. 400 kW in a soundproof container. Price is for the generator in the container. (Can be equipped with heat exchanger equipment) K19N-G4 engine; Leroy Somer TAL-A473 generator Voltage 230/400 Volts
used
Immediately available used exhaust gas compensator
used
Immediately available overhauled gas-oil flow covers, also used ones we have all in stock
new
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mo ...
new
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C170 D5 Enclosed A047W024 Genset Model C170 D5, 170kVA Standby, 155kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G7 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
new
C175 D5e Enclosed A049J778 Genset Model C175 D5e, 175kVA Standby, 160kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Wat ...
new
C200 D5e Enclosed A049J779 Genset Model C200 D5e, 200kVA Standby, 182kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274H, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% W ...
new
C275 D5 Enclosed A049K225 Genset Model C275 D5, 275kVA Standby, 250kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UCD274K, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
new
C330 D5 enclosed A048T878 Genset Model C330 D5, 330kVA Standby, 300kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC4D, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
new
C350 D5 Open A019J715 Genset Model C350 D5, 350kVA Standby, 320kVA Prime, NT855G6, Diesel, Open Emergency Standby Power (ESP) Emission Level; No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NT855G6 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4E, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole, End ...
new
C400 D5 Open A019J729 Genset Model C400 D5, 400kVA Standby, 360kVA Prime, NTA855G4, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G4 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4F, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole ...
new
C400 D5e Enclosed A029Z631 Genset Model C400 D5e, 400kVA Standby, 364kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC4F,50Hz,12 Leads,190 - 220V & 380 - 440V125C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 630A,690V IEC, 600V UL,4 P ...
new
C440 D5 Open A019J736 Genset Model C440 D5, 440kVA Standby, 400kVA Prime, NTA855G7, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G7 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HC5C, 50Hz, 12 Leads, 380-415V, 150C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 800A, 690V IEC, 600V UL, 4P ...
new
C500 D5 Enclosed Genset Model Item C500 D5, 500kVA Standby, 455kVA Prime, 0, 0, QSZ13G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SII Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSZ13G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC5C, 12 Leads, 50 Hertz (Hz), 190 - 220V and 380 - 440V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclo ...
new
C550 D5e Enclosed A029Z751 Genset Model C550 D5e, 550kVA Standby, 500kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC5D,50Hz,12 Leads,200V & 400V150C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 800A,690V IEC, 600V UL,4 Pole,100%,Left C ...
used
Cummins KTA50 D(M1) Marine Generator Set Stamford 1491 kva 60 Hz 3 Phase 2002 Model caglar@dortelgemi
used
Type: Engine, Type number: QST30-G2 GENERATOR 937,5KVA