We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
129,000 used machines on RESALE, but how to find them? Machine Search
new
Watercooled chiller/Heat pump Climaveneta NX WN 802 251 kW/282 kW Cooling capacity: 251 kW / 71.37 tons (12/7 — 35°C) Heating capacity: 282 kW / 80.19 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Compressors: 2 pcs. Copeland ZP485KCE-TWD-522 (scroll) Type of refrigerant: R410a Dimensions: 1.6x1.1x1.95 m Working hours: 124/102 h. Condition: Outlet
new
Watercooled chiller/Heat pump Climaveneta NX WN 1004 306 kW/340 kW Cooling capacity: 306 kW / 87.01 tons (12/7 — 35°C) Heating capacity: 340 kW / 96.68 tons (40/45 —7°C) Year of manufacture: 2018 Options: Heat pump. Hydraulic module. Kiplink Refrigerant circuit: 2 pcs. Heat exchanger: Plate Compressors: 4 pcs. Copeland ZP295KCE-TWD-522 (scroll) Type of refrigerant: R410a Hydraulic module: 2 pcs. water pump Grundfos TPED 80-210/2 Dimensions: 3.4x0.95x2 m Weight: 1500 kg Working hours: 0/0/0/0 h. Condition: New
new
Aircooled chiller Climaveneta NX K 0714P 194.1 kW Cooling capacity: 194.1 kW / 55.19 tons (12/7 — 35°C) Year of manufacture: 2023 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 2 pcs. Danfoss DSH184A4ALD (scroll) + 2 pcs. Danfoss DSH240B4APC (scroll) Type of refrigerant: R410a Number of fans: 4 pcs. Hydraulic module: 1 pcs. water pump Grundfos MGE90SB Dimensions: 3.2x2.3x2.5 m. Weight: 1930 kg. Working hours: 14/16/14/15 h. Condition: Outlet
new
Aircooled chiller/Heat pump Climaveneta NX N G06 LN K 0202P 44.9 kW/53.1 kW Cooling capacity: 44.9 kW / 12.77 tons (12/7 — 35°C) Heating capacity: 53.1 kW / 15.1 tons (40/45 —7°C) Year of manufacture: 2021 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Bitzer GSU60120VLB4-2 (scroll) Type of refrigerant: R454B Number of fans: 4 pcs. Dimensions: 1.9x1.2x2 m. Weight: 610 kg. Working hours: 0/0 h. Condition: New
new
Watercooled chiller/Heat pump Climaveneta NX W Y H 0302 96.7 kW/107 kW Cooling capacity: 96.7 kW / 27.5 tons (12/7 — 35°C) Heating capacity: 107 kW / 30.42 tons (40/45 —7°C) Year of manufacture: 2019 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Compressors: 2 pcs. Copeland ZP182KCE-TFD-477 (scroll) Type of refrigerant: R410a Dimensions: 1.25x0.95x1.65 m Weight: 520 kg Working hours: 56/36 h. Condition: Outlet
new
Watercooled chiller/Heat pump Climaveneta NX WN 0402 123 kW/136.9 kW Cooling capacity: 123 kW / 34.97 tons (12/7 — 35°C) Heating capacity: 136.9 kW / 38.93 tons (40/45 —7°C) Year of manufacture: 2022 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Compressors: 1 pcs. Bitzer GSU80295VLB4-2 (scroll) + 1 pcs. Bitzer GSU60235VLB4-2 (scroll) Type of refrigerant: R410a Dimensions: 1.7x1x2 m Weight: 760 kg Working hours: 17/16 h. Condition: Outlet
new
Chiller Clivet -Model: WSAN-YES 18.2 -The chiller has a heat pump -Cooling capacity: 53.1 kW -Heating capacity: 53.3 kW -Dimensions: 2340 x 1120 x 2130 mm -Number of fans: 2 x 750 mm -Year of production: 2021 -Power supply: 400V 50Hz 3N -Weight: 640 kg -Quantity in stock: 1 -Condition: new
new
Watercooled chiller Climaveneta FX W 0951 221.1 kW Cooling capacity: 221.1 kW / 62.87 tons (12/7 — 35°C) Year of manufacture: 2018 Refrigerant circuit: 1 pcs. Heat exchanger: Shell and tube Compressors: 1 pcs. Bitzer CSH7593-110Y-40P (screw) Type of refrigerant: R134A Dimensions: 3x1.2x1.7 m. Weight: 2000 kg. Working hours: 33 h. Condition: Outlet
new
Aircooled chiller/Heat pump KAMPMANN WSAN XSi 14.1 26.5 kW/31 kW Cooling capacity: 26.5 kW / 7.53 tons (12/7 — 35°C) Heating capacity: 31 kW / 8.81 tons (40/45 —7°C) Year of manufacture: 2019 Options: Heat pump. Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Mitsubishi Electric LNB65FAEMC (rotary, inverter) Type of refrigerant: R410a Number of fans: 1 pcs. ZKSN-750-8-10 Hydraulic module: 1 pcs. water pump WILO BAC40-125-0,75 Dimensions: 1.95x1.15x1.4 m. Weight: 365 kg. Working hours: 0 h. Condition: New
new
Watercooled chiller/Heat pump Climaveneta Prototipo PDC NX WN 1204 396 kW/439 kW Cooling capacity: 396 kW / 112.6 tons (12/7 — 35°C) Heating capacity: 439 kW / 124.8 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump Refrigerant circuit: 2 pcs. Heat exchanger: Plate Compressors: 4 pcs. Copeland ZP385KCE-TWD-522 (scroll) Type of refrigerant: R410a Dimensions: 2.65x0.89x1.8 m Weight: 1740 kg Working hours: 146/86/136/81 h. Condition: Outlet
used
Aircooled chiller RHOSS TCAEY133 33.8 kW Cooling capacity: 33.8 kW / 9.61 tons (12/7 — 35°C) Year of manufacture: 2015 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Panasonic C-SCP510H38B (scroll) Type of refrigerant: R410A Number of fans: 1 pcs. Dimensions: 1.6x1x1.57 m. Weight: 460 kg. Condition: Good
used
Watercooled chiller EF COOLING EVO 90 WKL770FC 88 kW Cooling capacity: 88 kW / 25.02 tons (12/7 — 35°C) Year of manufacture: 2019 Options: Hydraulic module. Freecooling (Dry cooler is additionally required) Refrigerant circuit: 2 pcs. Heat exchanger: Plate Compressors: 4 pcs. Copeland ZR125KCE-TFD-455 (scroll) Type of refrigerant: R407c Hydraulic module: 2 pcs. Grundfoss CM 10-5 + 1 pcs. Grundfoss CR20-2 + 1 pcs. Grundfoss CM15-1, expansion vessel, buffer tank 500 l. Dimensions: 2x1.3x2 m. Weight: 1700 kg. Working hours: 10432/10428/1333/1532 h. Condition: Good
new
Process cooling tower, air-cooled, Type: Cooling tower RAD 864/900 Cooling Tower, MTA S.p.A. - Rehsler RAD are compact water cooling towers that are suitable for outdoor installation. Including pump, water treatment for biocide and stabilizer and control and control cabinet. Cooling capacity kW 1113 Cold water temp. Exit/ Entry °C: 27 / 32 Volume flow m³/h: 192 Available Pump Pressure Bar: 3.27 Wet bulb temperature °C: 21, Air volume m³/h: 97200 Sound pressure in 10m free field dB(A): 64 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. current consumption (A) 125 Max. power consumption (kW) 86.6 Dimensions: Length mm 6600, width mm 2424, height mm 3180, Weight transport / operation kg: 4194 / 8449 Connection DN 150 FROM 9038 Year of construction 2020 Condition: Optical 1, Technical OK Test facility, as good as new Price: on reque ...
used
Inverter heat pump. Very good condition. Was used for heating. Closed circuit. Glycol. Serviced. Power approx. 53 kW
used
Watercooled chiller York YCSE0181 180 kW Cooling capacity: 180 kW / 51.18 tons (12/7 — 35°C) Year of manufacture: 2016 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Compressors: 1 pcs. Hitachi G50ASF-Z (screw) Type of refrigerant: R134A Dimensions: 1.25x0.8x1.68 m. Weight: 950 kg. Condition: Excellent
used
Available CENTION SAB-HW18 Absorption chiller machine on perfect condition. The year of manufacturing is February of 2012. It works with lithium bromide. Power: 633 kW Equipment ready to deliver at our wharehouse.
used
Aircooled chiller/Heat pump SYSTEMAIR SYSCROLL 20 AIR EVO HP 20 kW/20 kW Cooling capacity: 20 kW / 5.69 tons (12/7 — 35°C) Heating capacity: 20 kW / 5.69 tons (40/45 —7°C) Year of manufacture: 2020 Options: Heat pump. Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Mitsubishi Electric ANB42FPJMT (scroll) Type of refrigerant: R410a Number of fans: 2 pcs. Hydraulic module: 1 pcs. water pump EBARA matrix 5-2t Dimensions: 1.6x0.6x1.8 m. Weight: 281 kg. Working hours: 2330 h. Condition: Good
new
Watercooled chiller PANASONIC ECOi P WQE1004CA 295.6 kW Cooling capacity: 295.6 kW / 84.05 tons (12/7 — 35°C) Year of manufacture: 2023 Refrigerant circuit: 2 pcs. Heat exchanger: Plate Compressors: 4 pcs. Bitzer GSD80295VAB4-2 (scroll) Type of refrigerant: R410a Dimensions: 2.2x1x1.88 m. Weight: 1453 kg. Working hours: 0/0/0/0 h. Condition: New
used
Combined cooling system Year of manufacture 2021 If you have any questions, write
new
Watercooled chiller/Heat pump Climaveneta FOCS2 W H CA E 1601 441.9 kW/456.9 kW Cooling capacity: 441.9 kW / 125.65 tons (12/7 — 35°C) Heating capacity: 456.9 kW / 129.92 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump. Economizer. Refrigerant circuit: 1 pcs. Heat exchanger: Shell and tube Compressors: 1 pcs. Bitzer CSW9563-140CVY-40D (screw) Type of refrigerant: R134a Dimensions: 4.2x1x2.2 m Weight: 3570 kg Condition: Outlet
used
used
Watercooled chiller Trane ECGWN207BA2D11DC 251.7 kW Cooling capacity: 251.7 kW / 71.57 tons (12/7 — 35°C) Year of manufacture: 2010 Refrigerant circuit: 2 pcs. Heat exchanger: Plate Compressors: 4 pcs. Danfoss CSHN250K0AK0 (scroll) Type of refrigerant: R410a Dimensions: 2.54x0.88x1.84 m. Weight: 1420 kg. Working hours: 34500/34500/34500/34500 h. Condition: Good
new
Watercooled chiller/Heat pump CIAT LWHE 4628E0003- 1736 kW/ 1964 kW Cooling capacity: 1736 kW / 493.62 tons (12/7 — 30/35°C) Heating capacity: 1964 kW / 558.45 tons (40/45 —10/7°C) Year of manufacture: 2021 Options: Economizer. High efficiency. Heat pump. Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Compressors: 2 pcs. Carlyle 06TVW819SW3D.A42 (screw compressor with stepless control between 15% and 100%) Type of refrigerant: R134a Dimensions: 4.83x2.13x1.6 m. Weight: 9850 kg. Working hours: 0/0 h. Condition: New
used
Aircooled chiller McQuay MCEnergy MONO 073.1 SE ST 256 kW Cooling capacity: 256 kW / 72.79 tons (12/7 — 35°C) Year of manufacture: 2011 Options: Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. McQuay HSA204QS11YA (screw) Type of refrigerant: R134a Number of fans: 6 pcs. Hydraulic module: 1 pcs. water pump Lowara LNEE 65-125/55/P25 VCS4, expansion vessel. Dimensions: 3.07x2.24x2.23 m. Weight: 3119 kg. Working hours: 16221 h. Condition: Good
used
Aircooled chiller CARRIER 30RA 090 B0723 PEE 89 kW Cooling capacity: 89 kW / 25.31 tons (12/7 — 35°C) Year of manufacture: 2009 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. DANFOSS CSHA150KE (scroll) + 2 pcs. DANFOSS SZ120S4VC (scroll) Type of refrigerant: R407С Number of fans: 2 pcs. Hydraulic module: 1 pcs. water pump Ebara DWC-N/I300/1.1 IE3, expansion vessel. Dimensions: 2.3x2.07x1.33 m. Weight: 1093 kg. Working hours: 10730/12540/12570 h. Condition: Good
used
Aircooled chiller AERMEC ANL080 Y 20.35 kW Cooling capacity: 20.35 kW / 5.79 tons (12/7 — 35°C) Year of manufacture: 2019 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. COPELAND ZH19K1P-TFW-524 (scroll) Type of refrigerant: R410a Number of fans: 2 pcs. Dimensions: 1.12x0.55x1.25 m. Weight: 120 kg. Working hours: 7000 h. Condition: Good
used
Aircooled chiller AERMEC ANL102 Z 26.3 kW Cooling capacity: 26.3 kW / 7.48 tons (12/7 — 35°C) Year of manufacture: 2019 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 2 pcs. PANASONIC C-SBP160H38B (scroll) Type of refrigerant: R410a Number of fans: 2 pcs. Dimensions: 1.75x0.75x1.45 m. Weight: 270 kg. Working hours: 8000/8000 h. Condition: Good
used
used
Height=1.66 m, Overall length= 0.77 m, Overall width= 0.77 m, Net weight= 135 kg,
used
Watercooled chiller CARRIER 30XW 0452B0006 476 kW Cooling capacity: 476 kW / 135.35 tons (12/7 - 30/35°C) Year of manufacture: 2021 Refrigerant circuit: 1 pcs. Heat exchanger: Shell and tube Compressors: 1 pcs. Carlyle 06TUW483ST3D.A42 (screw) Type of refrigerant: R134a Dimensions: 2.73x0.93x1.7 m. Weight: 2423 kg. Working hours: 4956 h. Condition: Good
used
Height=1.62 m, Overall length= 0.88 m, Overall width= 0.81 m, Net weight= 167 kg,
used
Height=0.844 m, Overall length= 0.7 m, Overall width= 0.762 m, Net weight= 88 kg,
used
Height=1.515 m, Overall length= 0.69 m, Overall width= 0.755 m, Net weight= 135 kg,
used
Aircooled chiller Climaveneta NECS R B 3218 746 kW Cooling capacity: 746 kW / 212.12 tons (12/7 — 35°C) Year of manufacture: 2018 Options: Hydraulic module. Recuperation Refrigerant circuit: 4 pcs. Heat exchanger: Shell and tube Condenser: Copper / Aluminum Compressors: 8 pcs. COPELAND ZP485KCE-TWD-522 (scroll) Type of refrigerant: R410a Number of fans: 12 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump Lowara PLM160B14S3/3150 E3 Dimensions: 7.43x2.26x2.45 m Weight: 6850 kg Working hours: 6668/6668/6545/6791/6732/6732/6732/6732 h. Condition: Good
used
Daikin EWAQ040BAWHBH Water chiller Serial: 3400102 2014, Air cooled mini inverter scroll water chiller, 41.Kw, with Daikin EKBT 200L buffer tank with cabinet, 3Ph
used
Aircooled chiller/Heat pump CLIMAVENETA NECS N B S 0512 127 kW / 144 kW Cooling capacity: 127 kW / 36.11 tons (12/7 — 35°C) Heating capacity: 144 kW / 40.95 tons (40/45 —7°C) Year of manufacture: 2012 Options: Heat pump. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Copeland ZP295KCE-TWD-522 (scroll) Type of refrigerant: R410a Number of fans: 10 pcs. ( 5 pcs. frequency inverter driven) Dimensions: 3.25x1.12x1.62 m. Weight: 1030 kg Working hours: 1985/1985 h. Condition: Good
used
Aircooled chiller CLIMAVENETA NX2 G06 Y 0294T 270 KW Cooling capacity: 270 kW / 76.77 tons (12/7 — 35°C) Year of manufacture: 2020 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Microchannel, Aluminum Compressors: 4 pcs. DANFOSS DSH295A4APC (scroll) Type of refrigerant: R454B Number of fans: 6 pcs. Hydraulic module: 1 pcs. water pump Lowara PLM112RB14S2/340 E3 Dimensions; 4.34x2.25x2.29 m. Weight: 2580 kg. Working hours: 6233/6233/6233/6233 h. Condition: Good
used
Aircooled chiller CARRIER 30RBM 260 0014 PE 261 KW Cooling capacity: 261 kW / 74.21 tons (12/7 — 35°C) Year of manufacture: 2015 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum. Compressors: 4 pcs. Danfoss SH295A4ACE (scroll) Type of refrigerant: R410А Number of fans: 4 pcs. Hydraulic module: 1 pcs. water pump Lowara 00PPG000495200A, expansion vessel. Dimensions: 2.41x2.26x2.3 m. Weight: 1651 kg. Working hours: 1804/1756/1835/1723 h. Condition: Good
used
Aircooled chiller TRANE CGAM090 254.6 KW Cooling capacity: 254.6 kW / 72.39 tons (12/7 — 35°C) Year of manufacture: 2016 Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. TRANE CSHN315K0BKM (scroll) + 2 pcs. TRANE CSHN250K0BKM (scroll) Type of refrigerant: R410А Number of fans: 8 pcs. (2 pcs. frequency inverter driven) Dimensions; 3.65x2.3x2.35 m. Weight: 2498 kg. Working hours: 8866/8858/7036/7022 h. Condition: Good
used
Aircooled chiller DAIKIN EWAD460BZSS001 459 KW Cooling capacity: 459 kW / 130.51 tons (12/7 — 35°C) Year of manufacture: 2012 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Copper / Aluminum Compressors: 2 pcs. McQuay HSW3121QS11YA (screw, inverter) Type of refrigerant: R134А Number of fans: 12 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump LOWARA FCTE80-125/55/P Dimensions: 6.15x2.23x2.36 m. Weight: 5310 kg. Working hours: 46042/51397 h. Condition: Good
used
A small Daikin chiller with inverter is available. Refrigerant: R410A, refrigerant charge: 2.95kg, max. operating pressure high/low side: 4MPa/3MPa, max. water pressure: 3bar, weight: approx. 180kg. Documentation available. An on-site inspection is possible.
used
Aircooled chiller SYSTEMAIR SYSCROLL 420 AIR CO E COAT 414.2 KW Cooling capacity: 414.2 kW / 117.78 tons (12/7 — 35°C) Year of manufacture: 2016 Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 4 pcs. Bitzer GSD80485VAB4-2 (scroll) Type of refrigerant: R410а Number of fans: 8 pcs. Dimensions: 4.55x2.15x2.5 m. Weight: 2441 kg. Working hours: 5588/5528/7735/2825 h. Condition: Good
used
Aircooled chiller CIAT LDH 1800V STD 493 KW Cooling capacity: 493 kW / 140.18 tons (12/7 — 35°C) Year of manufacture: 2011 Options: Hydraulic module. Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 6 pcs. Copeland ZP385KCE-TWD-522 (scroll) Type of refrigerant: R410а Number of fans: 8 pcs. Hydraulic module: 1 pcs. water pump WILO DL80\160-11\2, expansion vessel, buffer tank. Dimensions: 6.66x2.2x2.45 m. Weight: 6626 kg. Working hours: 20974/19470/19396/19427 h. Condition: Good
new
Aircooled chiller AERMEC NRB0800 L 217 KW Cooling capacity: 217 kW / 61.7 tons (12/7 — 35°C) Year of manufacture: 2019 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 4 pcs. COPELAND ZP235KCE-TWD-522 (scroll) Type of refrigerant: R410а Number of fans: 4 pcs. (EC-fan) Hydraulic module: 2 pcs. water pump LOWARA PLM112RB14S2/340 E3, 2 pcs. expansion vessel, buffer tank. Dimensions: 2.78x2.2x2.45 m. Weight: 3590 kg. Working hours: 0/0/0/0 h. Condition: Outlet
used
A refrigeration unit ERS is available. Refrigerant: R407C, refrigerant quantity: 13kg, heat inlet/outlet temperature: 15°C/20°C, cooling capacity: 25580W, tank volume: 360l, pump capacity at 390kPa: 4.4m³/h, max. operating pressure low/high: 22bar/29bar. Machine dimensions: approx. 1650mm/900mm/2000mm, weight: approx. 930kg. Documentation available. An on-site inspection is possible.
new
Aircooled chiller MTA TAE EVO TECH 081 22 KW Cooling capacity: 22 kW / 6.26 tons (12/7 — 35°C) Year of manufacture: 2019 Options: Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Finned evaporator immersed in tank. Condenser: Copper / Aluminum Compressors: 1 pcs. Copeland ZP103KCE-TFD-477 (scroll) Type of refrigerant: R410а Number of fans: 1 pcs. Hydraulic module: 1 pcs. water pump Lowara CIE120/5/D, expansion vessel, buffer tank. Dimensions: 1.87x0.78x1.45 m. Weight: 341 kg. Working hours: 0 h. Condition: New
used
A complete Kretschmeyer chilled water system is available. Cooling capacity: 40.7kW, medium temperature inlet/outlet: 12°C/6°C, max. operating pressure low pressure/high pressure: 18bar/28bar, test pressure low pressure/high pressure: 26bar/40bar, refrigerant: R290, refrigerant charge: 4300g. Machine dimensions X/Y/Z: approx. 2800mm/1350mm/2350mm, weight: approx. 1050kg. Including hydraulic module, cooling water circulation pump, buffer tank, and remote maintenance module (monitoring package). Documentation available. An on-site inspection is possible.
used
Used Sabroe PAC 202 LM-A water cooled chiller on R717 (Ammonia). Complete with 1 Sabroe SAB 202 LM screw compressor, Schorch KN7315L-AX01B-Z electric motor - 50/60 Hz - 315/360 kW - 2965/3565 RPM, Sabroe OHU 4131 oil separator with a volume of 610 liter, Sabroe GHEA 083002-C separator with a volume of 1650 liter, Alfa Laval MK15-BWFGR plate heat exchanger, Alfa Laval MK15-BWFDR plate heat exchanger and a control cabinet with a Siemens TP700 Comfort controller. The chiller has a capacity of 1668 kW at a water inlet of 12°C and outlet 6°C. Specifications: Brand: Sabroe Type: PAC 202 LM-A Product type: Water cooled chiller Capacity kW: 1668,0 Capacity Tons: 474,3 Refrigerant: R717 Weight: 10.700 kg Dimensions: 5700x2330x3100 mm (LxWxH) Display: Siemens TP700 Comfort
used
Used Daikin EWAH350TZXRB2002 air-cooled chiller on Freon. Complete with 2 Daikin HSV3122US13 semi-hermetic screw compressors, condenser with 12 fans, Provides EV32271010H3 shell and tube as evaporator with a volume of 28 l (Water) / 28 l (R1234ze), Lowara LNEE 65-125/55/P25VCSX water pump and a control cabinet with a MicroTechIII controller. Brand: Daikin Type: EWAH350TZXRB2002 Product type: Air cooled chiller Capacity kW: 355 Capacity Tons: 100,9 Refrigerant: R1234ze Weight: 5423 kg Sizes: 5900x2270x2550 mm (LxWxH) Compressors: 2 Daikin HSV3122US13 Number of fans: 12 Year of built: 2019
used
Used Carrier 30 HXC 265 water cooled chiller on R134A. Complete with 2x Carrier 06NW2300S5EA-A00 & 1x Carrier 06NW1250S7EA-A00 semi-hermetic screw compressors, shell and tube condenser, shell and tube evaporator, 2 oil pumps, control cabinet with a display. Specifications: Brand: Carrier Type: 30 HXC 265 Product type: Water cooled chiller Capacity kW: 911,3 Capacity Tons: 259,1 Refrigerant: R134A Weight in kg: 4492 Sizes: 4250x900x2060 mm (LxWxH) Compressors: 2 Carrier 06NW2300S5EA & 1 Carrier 06NW1250S7EA-A00 Display: Carrier display
maximum number of results exceeded
please refine your search