We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
136,862 used machines on RESALE, but how to find them? Machine Search
new
Aircooled chiller/Heat pump CLIMAVENETA MEHP IB G07 15Y 13.5 kW/15.3 kW Cooling capacity: 13.5 kW / 3.84 tons (12/7 — 35°C) Heating capacity: 15.3 kW / 4.35 tons (40/45 —7°C) Year of manufacture: 2024 Options: Heat pump. Hydraulic module. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Mitsubishi DVB28FCQMT (scroll, inverter) Type of refrigerant: R32 Number of fans: 2 pcs. (EC-fans) Hydraulic module: 1 pcs. water pump Wilo Para MAXO G25-180-10-F02, expansion vessel. Dimensions: 0.43x0.92x1.4 m Weight: 150 kg Working hours: 83 h. Condition: Outlet
used
CHILLER ✔️ Brand: Carrier ✔️ Model: 30XA ✔️ Year: 2012 ✔️ Fluid: R134a ✔️ Load: ~134 kg ⚙️ Key features: Power consumption: ≈ 312 kW Max amperage: ≈ 522 A Power supply: 400V – Three-phase – 50 Hz Weight: ≈ 6723 kg
used
Aircooled chiller/Heat pump MTA TAEevo TECH 802 159 kW/184 kW Cooling capacity: 159 kW / 45.21 tons (12/7 — 35°C) Heating capacity: 184 kW / 52.32 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump. Hydraulic module. Refrigerant circuit: 2 pcs. Heat exchanger: Finned evaporator immersed in tank Condenser: Copper / Aluminum Compressors: 4 pcs. Copeland ZP182KQE-TFD-477 (scroll) Type of refrigerant: R410a Number of fans: 3 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump Lowara PLM112B14S2/355-E, expansion vessel. Dimensions: 3.54x1.25x2.2 m. Weight: 2500 kg. Working hours: 8650/7460 h. Condition: Good
used
Aircooled chiller/Heat pump CIAT AQUACIAT2 ILDC 240V 61.5 kW/64.1 kW Cooling capacity: 61.5 kW / 17.49 tons (12/7 — 35°C) Heating capacity: 64.1 kW / 18.23 tons (40/45 —7°C) Year of manufacture: 2015 Options: Heat pump. Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Copeland ZP137KCE-TFD-455 (scroll) Type of refrigerant: R410a Number of fans: 1 pcs. Hydraulic module: 1 pcs. water pump, expansion vessel. Dimensions: 2x1.06x1.75 m. Weight: 660 kg. Working hours: 6660/6659 h. Condition: Good
new
Aircooled chiller/Heat pump CLIMAVENETA NX N Y/CA 1104T 311 kW/327 kW Cooling capacity: 311 kW / 88.43 tons (12/7 — 35°C) Heating capacity: 327 kW / 92.98 tons (40/45 —7°C) Year of manufacture: 2023 Options: Heat pump. Hydraulic module. Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Copper / Aluminum Compressors: 2 pcs. Bitzer GSU80385VLB4-2 (scroll) + 2 pcs. Bitzer GSU80295VLB4-2 (scroll) Type of refrigerant: R410А Number of fans: 8 pcs. (EC-fans) Hydraulic module: 2 pcs. water pump Grundfos MGE112MC-2FF215-JA-400 (Frequency inverter) Dimensions: 6.12x2.23x2.15 m Weight: 3940 kg Working hours: 0/0/0/0 h. Condition: New
new
M.T.A. ARIES G 075 HE, Green R454B refrigerant, 227 kW effective output, Water IN/OUT 13°/7°C, Ambient temperature +35°C, 4 hermetic scroll compressors and 2 refrigeration circuits, Green R454B refrigerant, Global Warming Potential (GWP) = 467, which complies well in advance with the new F-Gas Regulation (EU) 2024/573, due to come into force on 1 January 2027 with a GWP ≤750, 4 condensers consisting of copper tubes and aluminium fins, NOT microchannels, Shell-and-tube evaporator, Evaporator anti-freeze heater, -20°C ambient temperature kit as option, Electrical panel heater, Brushless EC fans, availability: in stock, capacity: 227 kW cooling capacity, conditions: new machine, type: chilling unit
new
M.T.A.A ARIES TECH 2 105 HE, R410a New model year 2025:, 338 kW effective cooling capacity,, water inlet/outlet 20°/15°C, Ambient temperature +35°C, 4 hermetic scroll compressors and 2 refrigeration circuits, 4 condensers consisting of copper tubes and aluminium fins (NOT micro-channel), Shell-and-tube evaporator, Evaporator anti-freeze heater, -20°C ambient temperature kit option, Electrical panel heater, Brushless EC fans, availability: in stock, capacity: 338 kW cooling capacity, conditions: new machine, type: chilling unit
new
M.T.A.ARIES G 065 HE - new machine, Green R454b refrigerant, 150.000/200,000 BTU (174 / 232 kW), 198 kW effective output, Water IN/OUT 20°/15°C, Ambient temperature +35°C, Green R454B refrigerant, -- Global Warming Potential (GWP) = 467, which complies well in advance with the new F-Gas Regulation (EU) 2024/573, due to come into force on 1 January 2027 with a GWP ≤750 --, Shell-and-tube evaporator, 500-litre storage tank, P3 pump, Constructor Description:, The Aries G series liquid chillers are air-cooled units designed for outdoor use (electrical control panel protection rating IP54). All units are designed, manufactured and tested in accordance with ISO 9001 standards. The design of this range has focused on achieving full-load and seasonal efficiency ratings that meet the limits imposed by eco-compatible design regulations (ErP Tier 2 Compliant) for SEER and SEPR HT ratings, whil ...
new
Aircooled chiller CLIMAVENETA NX2 G06 0082 69 kW Cooling capacity: 69 kW / 19.62 tons (12/7 — 35°C) Year of manufacture: 2023 Options: Hydraulic module. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 2 pcs. Bitzer GSD60154VLB4-2 (scroll) Type of refrigerant: R454B Number of fans: 6 pcs. (EC-fans) Hydraulic module: 1 pcs. water pump Grundfos MGE90LC1-56C-IA-220 (Frequency inverter) Dimensions: 2.43x1.18x2.1 m. Weight: 780 kg. Working hours: 55/55 h. Condition: Outlet
new
Watercooled chiller/Heat pump Climaveneta NX W H 0182 55.9 kW/62.8 kW Cooling capacity: 55.9 kW / 15.89 tons (12/7 — 35°C) Heating capacity: 62.8 kW / 17.86 tons (40/45 —7°C) Year of manufacture: 2023 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Compressors: 1 pcs. Copeland ZP122KCE-TFD-418 (scroll) + 1 pcs. Copeland ZP104KCE-TFD-418 (scroll) Type of refrigerant: R410a Dimensions: 1.22x0.88x1.62 m Weight: 390 kg Working hours: 39/48 h. Condition: Outlet
new
Aircooled chiller/Heat pump GALLETTI MLE144PS2A 137 kW/154 kW Cooling capacity: 137 kW / 38.96 tons (12/7 — 35°C) Heating capacity: 154 kW / 43.79 tons (40/45 —7°C) Year of manufacture: 2025 Options: Heat pump. Hydraulic module. 4-pipe system. Refrigerant circuit: 2 pcs. Heat exchanger: 2 pcs. Plate Condenser: Copper / Aluminum Compressors: 4 pcs. Danfoss DSH161A4ALD (scroll, soft starter) Type of refrigerant: R454B Number of fans: 4 pcs. (Frequency inverter) Hydraulic module: 2 pcs. water pump EBARA 3M40-125/2.2-Q7AE-NEDN Dimensions: 3.8x2.02x1.97 m. Weight: 1795 kg. Working hours: 0/0/0/0 h. Condition: New
new
Aircooled chiller Climaveneta NX K 0202P 52 kW Cooling capacity: 52 kW / 14.79 tons (12/7 — 35°C) Year of manufacture: 2018 Options: Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 2 pcs. Copeland ZP112KCE-TFD-455 (scroll) Type of refrigerant: R410a Number of fans: 4 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump EBARA DWC-V 300/1, expansion vessel, buffer tank 90 l. Dimensions: 1.8x1.2x1.9 m. Weight: 740 kg. Working hours: 49/49 h. Condition: Outlet
new
Aircooled chiller CLIMAVENETA FX G04 A 0751 112 kW Cooling capacity: 112 kW / 31.85 tons (12/7 — 35°C) Year of manufacture: 2018 Options: KIP Link Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 1 pcs. Bitzer CSC7973-70Y-40P (screw) Type of refrigerant: R1234ze(e) Number of fans: 2 pcs. (EC-fans) Dimensions: 2.3x1.6x2.5 m. Weight: 1800 kg. Working hours: 0 h. Condition: New
used
MTA Chiller with the following specifications: Type: MTA PNP 280 Power: 611 kW Year of manufacture: 2009 Weight: 5.5 Ton 2x Bitzers Includes refrigerant coolant (R134)/gas.
new
Aircooled chiller YORK YGT550HE 535.3 KW Cooling capacity: 535.3 kW / 152.2 tons (12/7 — 35°C) Year of manufacture: 2024 Options: Leak detector Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Microchannel, Aluminum Compressors: 1 pcs. Bitzer CSH9663-160Y-40D (screw, inverter) + 1 pcs. Bitzer CSH9663-160Y-40D (screw) Type of refrigerant: R1234ze Number of fans: 10 pcs. (EC-fans) Dimensions: 6.2x2.16x2.66 m. Weight: 6297kg. Working hours: 0/0 h. Condition: New
new
Aircooled chiller/Heat pump YORK YCPB 420 364 kW/406 kW Cooling capacity: 364 kW / 103.5 tons (12/7 — 35°C) Heating capacity: 406 kW / 115.44 tons (40/45 —7°C) Year of manufacture: 2023 Options: Heat pump. Economizer. Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Danfoss PSH105A4EPA (scroll) + 2 pcs. Danfoss PSH065A4EPA (scroll) Type of refrigerant: R454B Number of fans: 7 pcs. (Frequency inverter) Dimensions: 4.45x2.25x2.42 m. Weight: 3100 kg. Working hours: 107/80/98/58 h. Condition: Outlet
used
Aircooled chiller Climaveneta FOCS-CA/SL 873 kW Cooling capacity: 873 kW (12/7 — 35°C) Year of manufacture: 2009 Heat exchanger: Shell and tube Refrigerant circuit: 2 pcs. Type of refrigerant: R134a Compressors: 2 pcs. Bitzer (screw) Number of fans: 12 pcs. Dimensions: 9.40 x 2.26 x 2.43 m Weight: 9 880 kg. Working hours: 30717/30184 h. Condition: Exellent
used
WATERCOOLED CHILLER/HEAT PUMP DAIKIN EWHQ120G 95/130 kW Cooling capacity: 95 kW - 27 ton (12/7°C — 35°C) Heating capacity: 130 kW - 36.9 ton (40/45°C - 7°C) Year of manufacture: 2019 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Options: Heat pump Type of refrigerant: R410A Compressors: 2 pcs. Copeland(scroll) Dimensions: 2,432 х 0,928 х 1,066 m. Weight: 729 kg. Working hours: 11437 / 4712 h. Condition: Excellent
used
Equipment: Insulation,Manufacturer: Schwarz Apparate- und Behälterbau,Condition: used,Remarks: 3 feet made of V2A with plastic rollers 2 crane eyelets,Type plate: Yes,Year of construction: 2002,Insulation: available,Volume sheath space: 216,Max. permissible Operating temperature sheath chamber: 80,Volume pipe space: 1,000,Max. permissible Operating temperature raw space: 80,Diameter outside: 520,Total height: 1,950
used
Equipment: Insulation,Manufacturer: Schwarz Apparate- und Behälterbau,Condition: Used,Remarks: A recooler has no nameplate. The recoolers have different connections.,Replacement area: 4.8,Type plate: Yes,Year of construction: 1995,Insulation: available,Volume jacket space: 210,Volume pipe space: 60
new
Aircooled chiller CLIMAVENETA I BX 015T 15.5 KW Cooling capacity: 15.5 kW / 4.41 tons (12/7 — 35°C) Year of manufacture: 2018 Options: Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Mitsubishi DNB36FAEMT (scroll, inverter) Type of refrigerant: R410а Number of fans: 2 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump Wilo Yonos PARA HF 25/10 (inverter), expansion vessel. Dimensions: 0.9x0.37x0.94 m. Weight: 140 kg. Working hours: 0 h. Condition: New
new
WATERCOOLED CHILLER PANASONIC P-WQE0075CA 77.3 KW Cooling capacity: 77.3 kW / 21.98 tons (12/7 — 35°C) Year of manufacture: 2024 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Plate Compressors: 2 pcs. Copeland ZP154KCE-TFD-477 (scroll) Type of refrigerant: R410A Dimensions: 0.85x1.25x1.6 m Weight: 392 kg Working hours: 10/10 h. Condition: Outlet
used
Aircooled chiller/Heat pump SYSTEMAIR SYSCROLL 20 AIR EVO HP 20 kW/20 kW Cooling capacity: 20 kW / 5.69 tons (12/7 — 35°C) Heating capacity: 20 kW / 5.69 tons (40/45 —7°C) Year of manufacture: 2014 Options: Heat pump. Hydraulic module Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Mitsubishi ANB42FPJMT (scroll, inverter) Type of refrigerant: R410a Number of fans: 2 pcs. Hydraulic module: 1 pcs. water pump EBARA matrix 5-2T/0,45 COIB, buffer tank 112 l. Dimensions: 0.51x1.48x2.01 m. Weight: 266 kg. Condition: Good
new
AIRCOOLED CHILLER CARRIER 30RB 080R PI1889 81.1 KW Cooling capacity: 81.1 kW / 23.06 tons (12/7 — 35°C) Year of manufacture: 2020 Options: Recuperation Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 2 pcs. Danfoss DSF175A4ACA (scroll) Type of refrigerant: R32 Number of fans: 1 pcs. (Frequency inverter) Dimensions: 2.11x1.09x1.33 m Weight: 464 kg Working hours: 0/0 h. Condition: New
new
AIRCOOLED CHILLER/HEAT PUMP CARRIER 30RQ 090RAPI1984 87 KW/93.3 KW Cooling capacity: 87.0 kW / 24.74 tons (12/7 — 35°C) Heating capacity: 93.3 kW / 26.53 tons (40/45 —7°C) Year of manufacture: 2023 Options: Heat pump. Hydraulic module. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Danfoss DSF200A4ACA (scroll) Type of refrigerant: R32 Number of fans: 2 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump Grundfos AC25-125, expansion vessel. Dimensions: 2.28x2.13x1.33 m Weight: 781 kg Working hours: 0/0 h. Condition: New
new
WATERCOOLED CHILLER CARRIER 30XW 0852B0010 829 KW Cooling capacity: 829.0 kW / 235.71 tons (12/7 — 35°C) Year of manufacture: 2024 Options: Economizer. Refrigerant circuit: 1 pcs. Heat exchanger: Shell and tube Condenser: Shell and tube Compressors: 1 pcs. Carlyle 06TVA819SX1D (screw) Type of refrigerant: R134a Dimensions: 2.78x0.9x1.9 m Weight: 3481 kg Working hours: 1 h. Condition: New
new
AIRCOOLED CHILLER YORK YSAQ 75 L.FSC.KM.AVM 75.14 KW Cooling capacity: 75.14 kW / 21.36 tons (12/7 — 35°C) Year of manufacture: 2022 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 1 pcs. Copeland ZP154KCE-TFD-477 (scroll) + 1 pcs. Copeland ZP182KCE-TFD-477 (scroll) Type of refrigerant: R410A Number of fans: 2 pcs. (Frequency inverter) Dimensions: 1.16x2.18x2 m Weight: 585 kg Working hours: 1/1 h. Condition: New
new
Aircooled chiller/Heat pump SYSTEMAIR SYSCROLL 30 28/26 kW Cooling capacity: 28 kW / 7.96 tons (12/7 — 35°C) Heating capacity: 26 kW / 7.39 tons (40/45 —7°C) Year of manufacture: 2016 Options: Hydralic module. Heat pump Hydraulic module: 1 pcs. water pump (EBARA) Heat exchanger: Plate Refrigerant circuit: 1 pcs. Compressors: 1 pcs. Mitsubishi (scroll, inverter) Type of refrigerant: R410A Number of fans: 2 pcs. Dimensions: 1,47 x 0,54 x 1,61 m Weight: 281 kg Working hours: 3 h. Condition: Excellent
new
Aircooled chiller/Heat pump Systemair SYSCROLL.330.AIR 308,3/333 kW Cooling capacity: 308,3 kW (12/7 — 35°C) Heating capacity: 333 kW (40/45 —7°C) Year of manufacture: 2018 Heat exchanger: Plate Refrigerant circuit: 2 pcs. Compressors: 4 pcs. Copeland (scroll) Number of fans: 8 pcs. Type of refrigerant: R410A Dimensions: 4.6 x 2.2 x 2.65 m Weight: 2899 kg Condition: Excellent, Outlet
used
Aircooled chiller/Heat pump DAIKIN EWYQ080 DAYN 77 kW/87 kW Cooling capacity: 77 kW / 21.9 tons (12/7 — 35°C) Heating capacity: 87 kW / 24.7 tons (40/45 —7°C) Year of manufacture: 2014 Options: Heat pump. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Danfoss SJ180B4ABE (scroll) Type of refrigerant: R410a Number of fans: 4 pcs. Dimensions: 2.6x2.1x2.35 m Weight: 1400 kg Working hours: 11860/11861 h. Condition: Good
used
Aircooled chiller/Heat pump TRANE RTMA105 368.7 kW / 411.8 kW Cooling capacity: 368.7 kW / 104.84 tons (12/7 — 35°C) Heating capacity: 411.8 kW / 117.09 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump. 4-pipe system (Hot/chilled simultaneous water production). Refrigerant circuit: 2 pcs. Heat exchanger: 2 pcs. Shell and tube Condenser: Copper / Aluminum Compressors: 2 pcs. Frascold CXH01-90-340Y (screw) Type of refrigerant: R134а Number of fans: 8 pcs. (Frequency inverter) Dimensions: 5.43x2.25x2.4 m. Weight: 6380 kg Working hours: 4138/1893 h. Condition: Good
used
Aircooled chiller LENNOX NAC 420D NM1M 420.1 kW Cooling capacity: 420.1 kW / 119.45 tons (12/7 — 35°C) Year of manufacture: 2008 Options: Hydraulic module Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 3 pcs. COPELAND ZP385KCE-TWD-524 (scroll) + 3 pcs. COPELAND ZP295KCE-TWD-524 (scroll) Type of refrigerant: R410a Number of fans: 8 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump WILO DPL65/175-75/2, expansion vessel. Dimensions: 5.7x2.3x2.1 m Weight: 3702 kg Working hours: 22188/22188/22188 24499/24526/24502 h. Condition: Good
used
Aircooled chiller/Heat pump TRANE RTMA170 594.2 kW / 675.7 kW Cooling capacity: 594.2 kW / 168.96 tons (12/7 — 35°C) Heating capacity: 675.7 kW / 192.13 tons (40/45 —7°C) Year of manufacture: 2016 Options: Heat pump. 4-pipe system (Hot/chilled simultaneous water production). Refrigerant circuit: 2 pcs. Heat exchanger: 2 pcs. Shell and tube Condenser: Copper / Aluminum Compressors: 2 pcs. Frascold CXH51-140-538Y (screw) Type of refrigerant: R134а Number of fans: 12 pcs. (Frequency inverter) Dimensions: 7.56x2.25x2.4 m. Weight: 8005 kg Working hours: 11801/2195 h. Condition: Good
used
AIRCOOLED CHILLER SWEGON COBALT PRO HE LN 37.2 350 KW Cooling capacity: 350.0 kW / 99.52 tons (12/7 — 35°C) Year of manufacture: 2015 Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Microchannel, Aluminum Compressors: 2 pcs. Bitzer CSH7593-90Y-40D (screw) Type of refrigerant: R1234ze Number of fans: 8 pcs. (Frequency inverter) Dimensions: 5.0x2.28x2.45 m Weight: 4480 kg Working hours: 620/870 h. Condition: Good
used
CHILLER Size: 50cm (L) x 50cm (H) PLEASE CONTACT MR. AMIRUL (+6017-9424446) Located at Factory 24
used
AIRCOOLED CHILLER LIEBERT FL4039 396 KW Cooling capacity: 396.0 kW / 112.6 tons (15/10 — 35°C) Year of manufacture: 2018 Options: Hydraulic module. Freecooling. Refrigerant circuit: 2 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Bitzer CSH7573-70Y40D (screw) Type of refrigerant: R134a Number of fans: 8 pcs. (EC-fans) Hydraulic module: 1 pcs. water pump Grundfos NB65-125/120-110 X-E-A GQQE + 1 pcs. Grundfos NB65-125/120-110 X-E2-A-BQQE + 1 pcs. Grundfos NB65-125/137-X-F-A-GQQE (Freecooling), expansion vessel. Dimensions: 5.1x2.31x2.6 m Weight: 5142 kg Working hours: 862/3889 h. Condition: Good
new
AIRCOOLED CHILLER STULZ WSJ4232MLA50Z00_1Z 819.9 KW Cooling capacity: 819.9 kW / 233.12 tons (12/7 — 35°C) Year of manufacture: 2025 Options: Hydraulic module. Freecooling. Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Microchannel, Copper / Aluminum (Freecooling) Compressors: 2 pcs. Bitzer CSHV37-240Y-40A (screw, inverter) Type of refrigerant: R1234ze Number of fans: 12 pcs. (EC-fans) Hydraulic module: 1 pcs. water pump Grundfos NBE 80-160/167 Dimensions: 8.2x2.25x2.51 m Weight: 9348 kg Working hours: 83/80 h. Condition: Outlet
used
Sehr kompakt gebautes Wasserkühlgerät / Very compactly built Watercooled Chiller Kühlgerät / Chiller ef cooling Ernst H. Furrer EVO 60 Typ WKL 520 Wasserkühlgerät / Watercooled Chiller Baujahr / Year 2020 - Serial-No. 0520.008/36732 Kälteleistung / Cooling capacity 60kW Kondensationsleistung / Condensation performance 84kW Anzahl Kältekreisläufe 1 / Number of refrigeration circuits 1 Kältemittel je Kältekreislauf / Refrigerant per refrigeration circuit R410A, 4.4kg 2 Verdichter / Compressor Pumpe / Pump CM 10-5 Grundfos Wärmetauscher / Heat exchanger Technische Dimensions: Length / Width / High 1800 x 850 x 2153mm Gewicht / Weight 640kgs
used
AIRCOOLED CHILLER TRANE RTAC 185 648 KW Cooling capacity: 648.0 kW / 184.25 tons (12/7 — 35°C) Year of manufacture: 2009 Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Copper / Aluminum Compressors: 1 pcs. Trane CHHP0N2TKG0N134A (screw) + 1 pcs. Trane CHHP0N1TKG0N112A (screw) Type of refrigerant: R134a Number of fans: 13 pcs. Dimensions: 7x2.30x2.6 m Weight: 6000 kg Working hours: 6001/6038 h. Condition: Good
used
AIRCOOLED CHILLER CLIMAVENETA NX2-G06 K 0424 398.9 KW Cooling capacity: 398.9 kW / 113.42 tons (12/7 — 35°C) Year of manufacture: 2022 Options: Hydraulic module. Refrigerant circuit: 2 pcs. Heat exchanger: Shell and tube Condenser: Microchannel, Aluminum Compressors: 2 pcs. Bitzer GSD80485VLB4-2 (scroll) + 2 pcs. Bitzer GSD80385VLB4-2 (scroll) Type of refrigerant: R454B Number of fans: 6 pcs. (Frequency inverter) Hydraulic module: 1 pcs. water pump Lowara PLM112B14S2/355 E3, expansion vessel, buffer tank 700 l. Dimensions: 3.91x2.26x2.56 m Weight: 3800 kg Working hours: 2260/2260/2259/2259 h. Condition: Good
used
AIRCOOLED CHILLER CLIMAVENETA NX2-G06 0122 118.1 KW Cooling capacity: 118.1 kW / 33.58 tons (12/7 — 35°C) Year of manufacture: 2022 Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Microchannel, Aluminum Compressors: 1 pcs. Bitzer GSD60235VLB4-2 (scroll) + 1 pcs. Bitzer GSD80295VLB4-2 (scroll) Type of refrigerant: R454b Number of fans: 2 pcs. Dimensions: 2.83x1.2x1.98 m Weight: 850 kg Working hours: 2219/2220 h. Condition: Good
new
AIRCOOLED CHILLER CLIMAVENETA NECS-C/HT 0302 80 KW Cooling capacity: 80.0 kW / 22.75 tons (12/7 — 35°C) Year of manufacture: 2017 Options: Hydraulic module. Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Copeland ZP182KCE-TFD-477 (scroll) Type of refrigerant: R410A Number of fans: 2 pcs. (centrifugal) Hydraulic module: 1 pcs. water pump Ebara DWC-VI 500/3.0 IE3, expansion vessel. Dimensions: 2.61x1.11x1.93 m Weight: 1160 kg Working hours: 0/0 h. Condition: Outlet
used
Yıldırım Soğutma AOU 120 Industrial Water Chiller Packaged industrial water-cooling unit with air-cooled condenser, twin compressor arrangement, circulation components, horizontal reservoir or heat-exchanger vessel and protective steel frame. Manufacturer: Yıldırım Soğutma Model: AOU 120 Year: 2017 Serial number: 120121620 Input power: 28 kW Electrical supply: 380 V, 3-phase, 50 Hz Rated current: 53 A Cooling capacity: 85 kW Refrigerant: R407C, approximately 13 kg Configuration: Air-cooled condenser, twin compressors, circulation system, reservoir or heat-exchanger vessel and steel frame Condition: Used Approximate dimensions: 2,600 × 1,300 × 2,400 mm Approximate weight: 950 kg All descriptions are indicative only. Auction-ID: A1-50546-74
new
Aircooled chiller/Heat pump LENNOX GAH055SM2M 53.6 kW/54 kW Cooling capacity: 53.6 kW / 15.24 tons (12/7 — 35°C) Heating capacity: 54 kW / 15.35 tons (40/45 —7°C) Year of manufacture: 2023 Options: Heat pump Refrigerant circuit: 1 pcs. Heat exchanger: Plate Condenser: Copper / Aluminum Compressors: 2 pcs. Copeland ZP120KCE-TFD-455 (scroll) Type of refrigerant: R410а Number of fans: 2 pcs. (EC-fans) Dimensions: 1.4x2.25x1.8 m. Weight: 701 kg. Working hours: 74/58 h. Condition: Outlet
used
Overview This KKT Kraus KLC 126 N is an air-cooled industrial chiller, built in 2003. It runs on refrigerant R407C, with the condenser fans on top and the control cabinet built into one end face. It served a Krones Contiform S24 blow moulder and was in production until March 2026. Dismantled in October 2026, it is now stored and ready for loading. Technical data Manufacturer: KKT Kraus Model: KLC 126 N Year of manufacture: 2003 Machine type: air-cooled chiller Refrigerant: R407C, max. filling weight 43.5 kg Max. operating pressure: 28 bar Power supply: 400 V, 3 phases, 50 Hz Max. power input: 64 kW Max. current consumption: 118 A Main fuse: 160 A CE marked Equipment Air-cooled condenser with axial fans on top of the housing Integrated control cabinet with digital temperature controller, indicator lamps, selector switch and main switch Pipe connections on the end face opposite the control ...
used
Overview This KKT Kraus KLC 126 N is an air-cooled compact chiller for industrial process cooling, built in 2004 by KKT-Kraus Industriekühlung GmbH (Germany). The unit combines the refrigeration circuit, the air-cooled condenser with top-mounted fans and the control cabinet in one enclosed housing. The water circuit connects via two flanged connections with pressure gauge on the end face. It cooled the process water of a Krones Contiform S24 stretch blow moulder. Technical data Manufacturer: KKT-Kraus Industriekühlung GmbH (Germany) Model: KLC 126 N Year of manufacture: 2004 Machine type: air-cooled compact chiller Refrigerant: R407C, filling weight max. 43.5 kg Max. operating pressure: 28 bar Power supply: 400 V, 3 phases, 50 Hz Max. power input: 67.5 kW Max. current consumption: 127 A Main fuse: 160 A CE marked Equipment Refrigeration circuit with air-cooled condenser coils along the ...
used
Horiba Scientific GenCo 1500 Laboratory Recirculating Chiller; ; Temperature range: +8 to +30°C; Power: 1900 watts; ; Missing rear sheet metal; ; Tested at 8°C; ; Internal reference: FA-2550; Auction-ID: A1-50994-1132
used
I offer a very well-preserved Aquatech CH 280 chiller with integrated pump and buffer tank from 2015. Until a few days ago, the machine was still running and supplied a climate chamber with cold water. There is also an exhaust duct arch.
maximum number of results exceeded