Execution:
Aggregate type:
stationary
Execution:
Contianer 20 Ft.
Technical data engine:
Engine manufacturer:
Volvo
Engine:
TAD 733 GE
Engine No.:
in production
Power:
201 KW
Cooling:
Water-cooled
Occasion:
Electric 24 V DC
Speed:
1500 rpm
Fuel:
Heating oil or diesel B7
Technical data generator:
Generator manufacturer:
Leroy Somer
Generator type:
VALLEY 044 M M 6S/4
Gene. No.:
in production
Generator power:
200 kVA
Voltage:
400 / 231 Volt
Power factor:
Cos. - PHI 0.8
Speed:
1500 rpm
Switchgear:
Execution:
Automatic start
Functions:
Emergency power parallel operation
Switch:
Generator switch 4 poles
Delivery:
Built
Tank:
Execution:
Base frame tank with drip pan
Content / liter:
360
Dimensions of the power unit:
Width approx. mm:
2.460
Height approx. mm:
2.550
Length approx. mm:
6.048
Weight approx. KG:
7.500
Stock number:
1317
Condition:
New
Year of construction:
2023
Delivery period:
3 Q 2023
Hours:
1
Location:
Verl - Germany
Scope of delivery:
Emergency generator, installed in a soundproofed 20 Ft. container,
emergency power supply as backup power system with a Volvo Penta
industrial diesel engine with electronic speed control and cooling
water preheating (230 volts) and Leroy Somer three-phase synchronous
generator. The motor and generator are elastically mounted on a common
skid frame.
Other additional features:
Tank capacity 1000 litres, refuelling directly at the tank
Fuel consumption at 50% load 23 litres/hour, sufficient for approx. 43
hours of operation
Fuel consumption at 100% load 46 litres/hour, sufficient for approx.
21 hours of operation
Internal automatic start-stop system (type: DSE 8620) with display of
all important engine and generator messages. Functional display
digitally on the display. Generator switch 4 poles integrated on the
A51268 aggregate (generator). Internal battery charger 230 volts –
12 volts DC
Automatic start with 4-pole mains and generator switching
Internal emergency power switchgear for installation in the container
and 4-pole mains generator switching (interruption-free)
Function: In the event of a power failure, the start command is
transferred to the diesel generator. When the nominal speed and
nominal voltage are reached, the generator switch is switched on. In
the event of a return to the mains, the automatic system monitors the
mains voltage. When this is stable again, the switch back to mains
operation takes place without interruption. The diesel generator is
stopped after the cooling time and waits in automatic mode for the
next power failure.
The emergency power system as an emergency power supply is ready for
operation and available from 03 Q 23 ex works Verl.