We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
135,956 used machines on RESALE, but how to find them? Machine Search
used
Price on request. FCA free loaded in our warehouse. One second hand Siemens Twin AFA 46 condensing steam turbine manufactured in 2009 for sale. turbine: Siemens type: Twin AFA 46 el. power: 3.300 KW running hours: steam consuption: steam inlet pressure: 26 bar inlet steam temperature:400°C manufactured: 2009 generator: AVK powerrating: 4.125 KVA volts: 6.300 volts Hz: 50 Hz price on request: Stromerzeuger-Discount Kürtener Straße 13 D-51465 Bergisch Gladbach Mobile: 0049/1635263546 Telefon: 0049/ 2202 2492256 Fax: 0049 2202 2492257 Email: info@stromerzeuger-discount.de
used
3692 KW Dresser Tuthill Nadrowski Tandem Condensation Turbine (steam turbine)for sale. 58.000 € plus VAT FCA freely charged in D-Bergisch Gladbach. Scope of supply: Steam turbo set and generator (6 KV). On request, generators with 10 to 11 KV are also available. A suitable capacitor costs 75,000 € extra. Not included: Control. Brand: Leroy-Somer Manufacturer: Tuthill Nadrowski Turbinen GmbH Type: LSA 56 BS 5- 4P Serial No.: 168233-1 Year of construction: 12-2001 Electr. Power: 3692 KW Power: 4625 KVA Voltage: 6000 V rpm: 1500 rpm Size (L x W x H): 3.10 m x 1.80 m x 2.70 m Weight: 10,000 kg Total output HD and ND turbine: 3692 KW. Total weight steam turbo set: 15 tons + 10 tons generator.
used
Kawasaki M7A-03D 7.2MW Natural Gas Turbine Complete CHP Generating Set Completely self-contained Kawasaki M7A-03D 7.2MW Gas Turbine and Generator package with Heat Recovery (Thermic Fluid Heater and HRSG Hot Water Generator) in acoustic enclosure. Runs parallel with grid. Island operation mode. Make and Model: Kawasaki TD80A Capacity: 7200kW Hrs: 10,000 V: 11,000 HZ: 50 Year: 2010 Fuel: Natural Gas Scope of supply: Gas Turbine GPB 80, M7A-03 DLE Single Gas Fuel, single shaft with DLE Combustor, reduction gear box, coupling with guard, Diaphragm Type, Generator (TD80A, 2011) Heat Recovery System - Thermic Fluid Heater, HRSG Hot Water Generator Acoustic Canopy with Lighting Control and Instrumentation Exhaust collector and/or diffuser, Gas Fuel system, Lube oil system, Inlet ducting, Inlet filtration system, Inlet silencer, Combustion system, Protection system ...
used
2 used steam turbine units available: 1. Type: B5 S2 + G IV Year: 1991 Turbine output: 294 kW at 1.35 bar and 170 C With exhaust gas heat exchanger 2. Type: B5 S3 + G IV Year: 1992 Turbine output: 330 kW at 1.35 bar and 170 C With exhaust gas heat exchanger Subject to prior sale - Errors possible
used
MAN NR34/S026 Turbocharger 1 new and 3 used available New bearings and repair sets also available in our stock in Istanbul Please contact: info@fin-marine
used
1 piece ABB TPL 77-B12 turbocharger complete available New In our stock in Istanbul Please contact: info@fin-marine
new
Discover an exceptional opportunity to acquire a new and unused Siemens Steam Turbine, perfectly suited for high-efficiency power generation: - Voltage: 11kV - Frequency: 50Hz - Speed: 1500rpm - Blower: Howden SO2, powered by a Siemens motor with a robust 2200kW capacity. - Condenser: High-efficiency Shell and Tube type for superior heat exchange. - Condensate Extraction: Sigma pump ensuring effective condensate management. - Vacuum Pump: Invatech water ring vacuum pump for optimal system performance. - Steam Generator: Clayton E-1204-SH, known for its reliability and efficiency in steam production. - Deaerator and Blowdown Tanks: Depression models to safeguard system integrity. - Boiler Feed Pumps: Hammelmann, designed for consistent and reliable water supply to the boiler. - Boiler Booster Pumps: Flowserve, enhancing the system's pressure cap ...
used
Centrax ROLLS ROYCE 5 MW CX 501 KB7 Gas Turbine-Generator Package YEAR 2011 HOURS 40 000 Equipment List: Turbine/Alternator Housing and its complete contents including: • 1 Allison 501 KB7S DLE Gas Turbine - • 1 Alternator • 1 Epicyclic Gearbox • 1 Acoustic Enclosure • 1 Alternator Control Cabinet and Software • 1 Turbine Control Cabinet and Software • 1 Auxiliary Distribution Cabinet and Software • 1 Lubrication Unit including Oil Cooler • 1 Fuel Supply Circuit in Acoustic Enclosure • 1 Electro-Hydraulic Starting System- • 1 Compressor Cleaning System • 1 DC Power Supply • Battery Charger • Fire Protection and Gas Detection Circuit • Fan acoustic enclosure • Air cooler fan List of components: • Control/command panel and room and its complete contents • Filtration assembly and combustion air ducts • Filtration assembly, silencers and box ventilat ...
used
Details of the equipment offered: • 1 Rolls Royce Type 501K-2044 turbine – ASP Engine Model 501-KB7, with sound-absorbing box • 1 ALEN GEARS Type STAR speed reducer – ASG34 • 1 Leroy Somer LSA 56 BUL85-4p / 6750 KVA alternator – 50 Hz • Natural gas control system • Box ventilation system • Electrical control cabinet • Fire Suppression System • Flue gas and water recovery boiler • Compressed air control system Characteristics: • Year of manufacture: 1999 • Total hours of service: 43,000 hours • Equipment still in operation, maintenance monitored by the manufacturer • Loading from France Overhauled in 2023 Photos and video available on request: This package represents an interesting opportunity for any company looking for a reliable and immediately operational solution. Do not hesitate to contact us for any further information, ...
used
1 x Steam turbine generator 3817 KW KKK Siemens CFR5 G6b 5,000 KWe x 1,500 rpm 50 Hz 6,300 V for sale in operational condition Turbine Manufacturer KKK Siemens Model CFR5 G6b Steam pressure fresh [bar] 64 Dampfdr. Ed. [bar] 8.5 Generator Manufacturer INDAR Model BZK-710-S/A-4 P Generator [KW] 5.000 Turn around. [per min] 1,500 Frequency [per sec] 50 Voltage [V] 6,300 Current [A] 458 Scope of delivery: The system has been completely dismantled and is complete including the control system. Technical documentation: available Spare parts / tools: not available The plant was dismantled in working order. Last major overhaul: unknown Sales are "as is" or after prior inspection by a company engaged by us on request
used
Available in stock 1 x Used Capstone TET. The unit is used but in good working conditions. Note: We have several Capstone parts in our stock to sell. If you are looking for something in particular, please contact us and we will see if we have anything to fulfill your request.
used
537 KW Tuthill Nadrowski back-pressure steam turbine C4. S-GIII from 2004, only turbine (was used as a pump). 1 available inlet pressure 90 bar, outlet pressure 18 bar, Price: € 19,500 each, plus VAT and FCA-free Manufacturer: TUTHILL Nadrowski Model: C4. S-G III Type: Steam Back Pressure Serial Number: 21004 Power [kW]: 537 Pressure inlet [bar]: 90 Pressure outlet [bar]: 18 Speed (rpm) 3.554 Year of construction: 2004 Weight [kg]: 2.440 Dimensions LxWxH [cm]: 370x138x174
new
Steam turbine Siemens SST400 Year: 2011 Disassembled and put in a storage. Very low working hours. Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Turbo gear unit Flender-Graffenstaden TX80/3 Transformer Siemens S10-40000/110 Condenser Full set of manual books No boilers, no voltage control cabinet (7) Steam turbine Siemens SST-400 Year: 2011 Never used and never installed. Still in original wooden crates. Packing lists. 7 sets available Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Control system Accessories Full set of manual books No boilers Price: on request
used
Kaplan turbine Escher Wass with standing shaft, used very good condition Gradient 7.00m-7.2 m Water volume 6000l/sec, power 500 hp, speed 375T/min
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -from: scrubbing machine make Gansow -Number: 17x available -Price: per piece -Dimensions: Ø 145/H210 mm -Weight: 2.7 kg
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -Manufacturer: Lamb Electric, suction motor from Gansow scrubber-dryer -Voltage: 24 V -Quantity: 29x available -Price: per piece -Dimensions: Ø 145/H175 mm -Weight: 2.3 kg/pc.
used
Taurus 60 Turbine Generator Set Solar Taurus 60 T7301 Gas Turbine Engine Runnig hour 1165 hour after last Overhaul Output Power 5200 Kw Gearbox Solar Gear Unit 1165 hour after last Overhaul Type: Epicyclic Leroy Somer Generator 50 Hz
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner, suction motor -Manufacturer: Ell, suction motor from scrubber dryer Gansow 70 BF 70 -Type: 500W -Voltage: 24 V -Quantity: 1 available -Dimensions: Ø 147/H210 mm -Weight: 2.8 kg
used
Dear Ladies and Gentlemen, We constantly have transformer stations for wind turbines in every power and voltage.
used
Unused Dresser-Rand Steam Turbine Generator Package – Never Commissioned Dresser-Rand Steam Turbine Available for immediate sale is a never-installed, never-operated Dresser-Rand steam turbine, manufactured in 2009. This unit has remained unused since manufacture and includes the original drawings and documentation. Steam Turbine Specifications Manufacturer: Dresser-Rand Year: 2009 Condition: Unused – Never Put Into Service Maximum Steam Inlet: Flow: 500 KPH Pressure: 925 psig Temperature: 750°F Maximum Extraction: Flow: 31 KPH Pressure: 352 psig Temperature: 543°F Exhaust Configuration: Up Exhaust for Condensing Outlet Documentation: Includes original drawings and documentation Brush Generator Paired with the turbine is a Brush generator, also unused and never commissioned. Generator Specifications Manufacturer: Brush Voltage: 13.8 kV Frequency: 60 ...
used
Ansaldo Condensing Steam Turbine Power: 9000 kW RPM: 7500 / 1500 Steam pressure: 40bara Steam temperature: 420 ºC Back Pressure: 0,08bar Number of extractions: 2 Number of stages: 8
used
BVI / ThyssenKrupp Condensing steam turbine MARC6-C03 2005 power generator with 135,000 operating hours, without steam condenser and AC generator. Inlet pressure 89 bar, outlet pressure 0.11 bar, 21,000 KWel x 1,500 rpm, Steam turbine BVI / ThyssenKrupp MARC6-C03 Manufacturer: BVI / ThyssenKrupp Model No.: MARC6-C03 Type: Steam Condensation Serial number: P-900078 Power [KW]: 23,545 Pressure Input [bar]: 89 Temperature Input [°C]: 520 Pressure output [bar]: 0.11 Year of Make: 2005 Hours: 135,000 Weight [kg]: 58,000 Dimensions LxWxH [cm]: 510x400x340
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
Manufacturer: Enercon Year of manufacture: 2006 (originally installed) Model: E70 Type of machine: Wind Turbine Capacity: 2.3 MW per unit Condition: Used Equipment available / The package can include: Nacelles, Generators / drive train components, Hubs, Complete blade sets, Electrical cabinets and associated equipment, Various spare parts and auxiliary components Please note that the existing towers are not included Find more here - .ucymachines/ Contact us at - sales@ucymachines
used
Mitsubishi Heavy Industries Ltd Type - SC1F ( Single Cylinder Single Flow ), Condensing Steam Turbine Power : 205.440MW HP Steam : 85 ata, 538 C LP Steam : 5.5 ata 193 C Steam Turbine Generator Model : MB-H Power - 241, 680 KVA Voltage - 16.5KV, 50 Hz
used
Model: Avon 1533-56L Year of Manufacture: 1992 Type: Aeroderivative Gas Turbine Rated power: Approximately 16,347 kW (22,225.73 hp) to 17,007 kW (23,123.08 hp) DIRECTINDUSTRY Thermal Efficiency: Up to 44% Dimensions: Length: Approx. 3,200 mm Diameter: approx. 907 mm Weight: Approximately 1,310 kg
used
Capacity: 3,224 kW Volts: 400 HZ: 50 Condition: Very Good Scope of Supply: Complete Turbine Power Station with turbine and alternator, Control Panel, Condensor, Cooling Towers, Spilling Unit, Switchgear, Synchronisation panel, Transformer, Piping / wiring / pumps. Total cost for power plant components was around 3 million on the actual power plant components. Nominal Steam requirement to run the turbine is 17, 5 t/h at 29 barg & 350 °C. Available for sale from Gas Engine Exchange . Please check our full range of equipment at gasengineexchange.com.
used
APE gearbox (Dualbox) geabox Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm
Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Total weight: 1000 kg
used
Turbine power 330 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Turbine power 294 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Siemens steam turbine 3,370 kW nominal output. Speed: 11,500 r/min, live steam 80 bar, live steam 500 °C.
used
Manufacturer: Siemens Model: SST-060 Year of Manufacture: 2016 Output Power: 1006 kW (nominal) Speed: 1500 rpm (nominal) Trip Speed: 1605 rpm Live Steam (Inlet Pressure): - Min: 20.6 bar - Nominal: 23.0 bar - Max: 25.4 bar Live Steam (Inlet Temperature): - Min: 300 °C - Nominal: 350 °C - Max: 378 °C Exhaust Steam (Outlet Pressure): - Min: 2.10 bar - Nominal: 3.10 bar - Max: 4.10 bar Exhaust Steam (Outlet Temperature): - Max: 331 °C Find more here - .ucymachines/ Contact us at - sales@ucymachines
used
Manufacturer: KKK Model: CF 5 G Year of Manufacture: 1986 Output Power: 412 kW Inlet Steam Pressure: 19 bar (Normal) Outlet Steam Pressure: 3 bar (Normal) Inlet Steam Temperature: 300°C (Normal) Alternator Features: Brand: AVK Alternator Type: DKBN80/500-4TS Power: 482 KVA (400 V, 696 A, 50 Hz) Year of Manufacture: 1986
used
Turbine Control Woodward 505 Turbine control, built in 2007 of 2600 KW Condensation turbine with 0 operating hours 1 available. 3.3 KV / 100 V, 50 Hz, 626 A Price: 6,900 €, plus VAT, FCA-free. Turbine Control Woodward 505 Manufacturer: Woodward Type: Turbine Control Rated power [KVA]: 3,575 Voltage [V]: 3.3 KV / 100 V Frequency [Hz]: 50 Operating voltage [V]: 24 Rated voltage [A]: 626 Year of Make: 2007 Dimensions [m]: 1.60 x 0.60 x 2.00 Weight [kg]: 500
used
12mw steam turbine major overhauled end 2022 only runs for 1 year till end 2024
used
3 Allison Turbine Detroit Diesel Allison Type 501 KB Year of manufacture 1980 alternator RATED 3860KW alternator DUTY 3355KW Alison turbine = 4380 HP --> domestic fuel oil INPUT RPM 14210 OUTPUT RPM 1500 Number of hours 600H of operation 10 KV cell (alternator output) Deutz 160 HP diesel (turbine launcher) 10 kW generator set – Deutz engine (Auxiliary power)
used
Type 501 KB Year of manufacture 1980 alternator RATED 3860KW alternator DUTY 3355KW Alison turbine = 4380 HP --> domestic fuel oil INPUT RPM 14210 OUTPUT RPM 1500 Number of hours 600H of operation 10 KV cell (alternator output) Deutz 160 HP diesel (turbine launcher) 10 kW generator set – Deutz engine (Auxiliary power)
used
A total of five identical Vestas wind turbines are expected to be available from early 2027. Rated power: 850kW, rotor area: 2124m², rotor blades: 3, rated speed: 26rpm, generator voltage: 690V, gearbox stages: 3, cut-in wind speed: 4m/s, rated wind speed: 16m/s, cut-out wind speed: 25m/s, tower material: steel, hub height: 74m, nacelle weight: 22t, rotor weight: 10t. Documentation available. An on-site inspection is possible. Individual sale possible.
new
Titan T250 Specifications Condition New / Never Used Status Disconnected. Preservation inspection was done in the Fall of 2020 and another inspection in 2022. Manufactured Solar Turbines 2017 Driver Solar Turbines Titan 250 Natural Gas Turbine / Version 30002S CS/MD Max HP 30,000 HP Rated RPM 10,500 RPM Control Panel Solar Turbotronic CTLM02
new
One (1) Surplus/Never use/never installed Siemens SGT-500 14 MW, 60 Hz. HFO Turbine-Generator for Simple Cycle operations. DESCRIPTION: Gas Turbine SGT-500 Combustion Chamber for gas, HFO and Diesel fuel capability Evaporative air inlet cooling Power output at 90% of operating time: 14MW Power output at 10% of operating time: 17MW Delivery: On stock – prior sale
used
5-blade wind generator for 5 kW per day (500Wp), complete with controller. Never used Overall dimensions: 1000 x 800 x 500 mm Weight: 20 kg Auction-ID: A7-49495-230
used
5-blade wind generator for 5 kW per day (500Wp), complete with controller, never used Overall dimensions: 1000 x 800 x 500 mm Weight: 20 kg Auction-ID: A7-49514-171
used
5-blade wind generator for 5 kW per day (500Wp), complete with controller. Never used Overall dimensions: 1000 x 800 x 500 mm Weight: 20 kg Auction-ID: A7-49514-29
used
5-blade wind generator for 5 kW per day (500Wp), complete with controller. Never used Overall dimensions: 1000 x 800 x 500 mm Weight: 20 kg Auction-ID: A7-49495-319
used
5-blade wind generator for 5 kW per day (500Wp), complete with controller, never used Overall dimensions: 1000 x 800 x 500 mm Weight: 20 kg Auction-ID: A7-49514-313
used
Power: 143 kW Steam requirement: 2,200 kg/h, 1.8 ba Including condensate tank from Westfalia Wärmetechnik Auction-ID: A7-49594-19
used
- Power: 4000 KW. - Turbine speed: 8700 rpm. - Inlet steam pressure: 40 bar. - Outlet steam pressure: 3 bar. - Exhaust vapour pressure: 0.1 bar. - Inlet steam temperature: 400°C. - LEROY-SOMER LSA 56 BUL85-4P generator: capacity 4000 KW. - Reducer: SEISA HDS050T . - Gearbox serial number: 00-7K1180 . - Year of gearbox: 2000 . - Reduction ratio: 1/5.806. - Lubrication: ISO VG32. - Rated power of gearbox: 3500 kW. - Input speed: 8700 rpm. - Output speed: 1500 rpm. - Operating conditions of this machine: unchecked. - EX WORKS sale. Disassembly, disconnection, loading and removal at the expense of the buyer, who must comply with current regulations on occupational risk prevention, health and safety in industrial work, providing the necessary documentation, insurance and accreditations. Auction-ID: A7-49881-17
used
- Power: 3500 KW. - Turbine speed: 8700 rpm. - Inlet steam pressure: 40 bar. - Outlet steam pressure: 3 bar. - Exhaust vapour pressure: 0.1 bar. - Inlet steam temperature: 400°C. - LEROY-SOMER LSA 56 BL65-4P generator: capacity 3500 KW. - Reducer: SEISA HDS050T . - Reduction ratio: 1/5.806. - Lubrication: ISO VG32. - Rated power of gearbox: 3500 kW. - Input speed: 8700 rpm. - Output speed: 1500 rpm. - Industrial steam installation with insulated pipes and valves. - Used for the generation of combined heat and electricity (cogeneration). - Operating conditions of this machine: unchecked. - EX WORKS sale. Disassembly, disconnection, loading and removal at the expense of the buyer, who must comply with current regulations on occupational risk prevention, health and safety in industrial work, providing the necessary documentation, insurance and accreditations. Auction-ID: ...
used
Complete gas measuring station, gas warning meter, Polytron IR Ex, Dräger, used Special price If you have a VAT number, we will be happy to issue you with an invoice without VAT. Used! The part was purchased from a spare parts warehouse of a company, is in very good condition and fully functional. The complete gas measuring device is installed in a Rittal distribution cabinet and consists of: - Rittal distribution cabinet 60 x 30 x 80cm high - Air intake pump, IKS Group, 7006 VD 2,3/E/AC - Gas detector Dräger, Polytron IR Ex, - Brooks variable area flow meter 1355/... - Isolating amplifier Pepperl u Fuchs KFA6-SR2-Ex1.W - Circuit breaker and other accessories The air intake pump sucks in the air from the outdoor area and brings it to the Polytron gas detector Ensuring the function In order to ensure functionality, the buyer must inspect or put the goods into op ...
maximum number of results exceeded