We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
136,085 used machines on RESALE, but how to find them? Machine Search
used
Details of the equipment offered: • 1 Rolls Royce Type 501K-2044 turbine – ASP Engine Model 501-KB7, with sound-absorbing box • 1 ALEN GEARS Type STAR speed reducer – ASG34 • 1 Leroy Somer LSA 56 BUL85-4p / 6750 KVA alternator – 50 Hz • Natural gas control system • Box ventilation system • Electrical control cabinet • Fire Suppression System • Flue gas and water recovery boiler • Compressed air control system Characteristics: • Year of manufacture: 1999 • Total hours of service: 43,000 hours • Equipment still in operation, maintenance monitored by the manufacturer • Loading from France Overhauled in 2023 Photos and video available on request: This package represents an interesting opportunity for any company looking for a reliable and immediately operational solution. Do not hesitate to contact us for any further information, ...
used
BVI / ThyssenKrupp Condensing steam turbine MARC6-C03 2005 power generator with 135,000 operating hours, without steam condenser and AC generator. Inlet pressure 89 bar, outlet pressure 0.11 bar, 21,000 KWel x 1,500 rpm, Steam turbine BVI / ThyssenKrupp MARC6-C03 Manufacturer: BVI / ThyssenKrupp Model No.: MARC6-C03 Type: Steam Condensation Serial number: P-900078 Power [KW]: 23,545 Pressure Input [bar]: 89 Temperature Input [°C]: 520 Pressure output [bar]: 0.11 Year of Make: 2005 Hours: 135,000 Weight [kg]: 58,000 Dimensions LxWxH [cm]: 510x400x340
new
1. EQUIPMENT OVERVIEW SIEMENS SGT-500 GAS TURBINES Quantity: Two (2) Units Available Condition: New Surplus / Zero Hours Manufacturing & Storage • Manufactured in 2007 • New surplus, never used • Zero operating hours • Stored strictly in accordance with OEM preservation procedures • Originally supplied for an FPSO project that was cancelled Certification • Marine Rated • DNV (Det Norske Veritas) certified 2. GAS TURBINE – TECHNICAL DATA • Model: Siemens SGT-500 • Configuration: Single-shaft industrial gas turbine • Fuel: Dual fuel – Natural Gas / Diesel • Frequency Capability: 50 / 60 Hz Power Output (ISO conditions – indicative) • Natural Gas: approx. 17.4 MW • Diesel: approx. 17.0 MW (Output may be slightly higher depending on site conditions) Performance • Specific Fuel Consumption • 221 g/kWh (Na ...
used
SALES PROPOSAL GAS TURBINE PACKAGE – SOLAR TAURUS 70 1. General Information Equipment: Industrial Gas Turbine Package Manufacturer: Solar Model: Taurus 70 – 10302S CS/MD Stand Core Turbine Year: 2019 Package Year: 1997 Condition: Used – Good Operating Condition 2. Technical Specifications • Output: 8,500 kVA • Frequency: 50 Hz • Voltage: 11,000 V • Alternator: LS – 6,300 V • Fuel Type: Natural Gas 3. Operating Data • Total Package Hours: 14,517 hours • Number of Starts: 127 • Next Planned Major Overhaul: 30,000 running hours • Borescope Inspection: Completed in 2024 (report available upon request) 4. Key Advantages ✔ 2019 Core Turbine (recent upgrade) ✔ Low number of starts ✔ Recent borescope inspection ✔ Suitable for 50 Hz industrial power generation ✔ Natural gas operation 5. Commercial Terms • Availability: To be con ...
new
We are pleased to present an exclusive offer for two fully re-manufactured SGT-300 gas turbines with a mechanical drive configuration (8 MW) and one gearbox (1500 rpm, 50 Hz), originally manufactured in 2018. These units have been fully overhauled to zero hours, providing up to 48,000 operational hours, and were serviced in a Siemens-approved workshop. Key Features – 8 MW Mechanical Drive: • Power output: 8.4 MW • Efficiency: 35.3 % • Heat rate: 10,204 kJ/kWh (9,666 Btu/kWh) • Exhaust temperature: 490 °C (914 °F) • NOₓ emissions: ≤ 15 ppmvd • Fuel flexibility: Natural gas, liquid fuel, dual fuel Commercial Advantages: • Offer price including gearbox: on request • Ready for immediate deployment • Siemens-approved quality and service, zero-hour units This is a rare opportunity to acquire high-performance turbines ...
used
6.6 MW MAN THYSSEN Extraction Condensing Steam Turbine Manufacturer: MAN THYSSEN Year of Construction: 1999 Condition: Used – In Good Running Condition Availability: In Stock Technical Data: Rated Power Output: 6.6 MW Voltage: 11 kV Frequency: 50 Hz Steam Inlet Conditions: Pressure: 40 bar Temperature: 440 °C Extraction Performance: 6 MW with 50 t extraction – 65 t/h 6 MW with 16 t extraction – 45 t/h 5 MW with 0 t extraction – 28 t/h Extraction Steam: Pressure: 12 bar Temperature: 294 °C Exhaust Steam: Pressure: 0.25 bar Temperature: 65 °C Description: Well-maintained German manufactured extraction condensing steam turbine suitable for industrial power generation and combined heat and power applications. The unit is designed for continuous operation and is ideal for sugar mills, textile plants, paper mills, chemic ...
used
10 MW W H-ALLEN Bedford England Back Pressure Steam Turbine Manufacturer: W H-ALLEN, Bedford, England Type: Back Pressure Steam Turbine Condition: Used – In Good Industrial Condition Availability: In Stock Technical Specifications: Rated Power Output: 10 MW Rated Speed: 7,750 RPM Voltage: 11 kV Frequency: 50 Hz Steam Conditions: Inlet Steam Pressure: 44.8 bar g Inlet Steam Temperature: 400 °C Exhaust Steam Pressure: 1 to 5.2 bar g Heavy-duty British-manufactured back pressure steam turbine designed for continuous industrial power generation and process steam applications. This unit is suitable for combined heat and power systems in sugar mills, textile plants, paper mills, chemical industries, and other steam-based manufacturing facilities. The turbine operates at high efficiency with stable back pressure performance, making it ideal for facili ...
used
20 MW STAL-LAVAL Industrial Steam Turbine Generator Set Manufacturer: STAL-LAVAL (Sweden) Type: Industrial Multi-Stage Steam Turbine Configuration: Condensing / Extraction-Condensing Manufacturing Era: Circa 1963–1964 Condition: Industrial Condition – Available for Inspection Availability: In Stock Power & Electrical Data: Rated Output: Approx. 20 MW Frequency: 50 Hz Rated Speed: 3000 RPM Generator: STAL-LAVAL GTP Series Generator Poles: 2-Pole Turbo Alternator Cooling System: Radial-flow air ventilation with filtration Coupling: Direct-coupled turbine-generator set Steam Design Parameters: Steam Pressure Class: Approx. 65 bar Steam Temperature (Design): Approx. 480–520 °C Operating Mode: Condensing turbine with surface condenser (extraction capable) Exhaust System: Shell and tube surface condenser Technical Features: Curtis con ...
used
Manufacturer: AEG Germany Equipment Type: Back Pressure Steam Turbine Generator Power Output: 11,200 kVA (≈ 9 MW) Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Type: S 688/4 Condition: Available As-Is, Where-Is Technical Specifications Electrical Output: 11,200 kVA (9 MW) Inlet Steam Pressure: 65 bar Inlet Steam Temperature: 440 °C Steam Consumption (Full Load): 60 tons/hour Exhaust Steam Pressure: 2.5 bar (Max) Exhaust Steam Temperature: 190 °C Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Insulation Class: B Description High-capacity AEG Back Pressure Steam Turbine Generator designed for industrial power generation and energy recovery applications. This 9 MW steam turbine system is suitable for industries with continuous steam availability such as: Sugar mills Textile mills Chemical plants Paper mil ...
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -from: scrubbing machine make Gansow -Number: 17x available -Price: per piece -Dimensions: Ø 145/H210 mm -Weight: 2.7 kg
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -Manufacturer: Lamb Electric, suction motor from Gansow scrubber-dryer -Voltage: 24 V -Quantity: 29x available -Price: per piece -Dimensions: Ø 145/H175 mm -Weight: 2.3 kg/pc.
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner, suction motor -Manufacturer: Ell, suction motor from scrubber dryer Gansow 70 BF 70 -Type: 500W -Voltage: 24 V -Quantity: 1 available -Dimensions: Ø 147/H210 mm -Weight: 2.8 kg
used
Solar Mars 100 Gas Turbine Engine – 15,000 HP Specifications Manufacturer: Solar Model Mars 100 Year 2019 Power Rating 15,000 HP Fuel Type Natural Gas Configuration Two-Shaft Gas Turbine Emissions Ultra Low SoloNox Condition Used – Engine Only Hours Since Overhaul 20,040 Hours Description Available for sale is a 2019 OH Solar Mars 100 two-shaft gas turbine engine designed for demanding industrial power applications. This unit features Ultra Low SoloNox emissions technology, providing improved environmental performance while maintaining high operational efficiency. The engine has accumulated 20,040 hours since overhaul and delivers a dependable output of 15,000 horsepower, making it an excellent solution for facilities requiring robust and reliable power generation or mechanical drive capability. Designed to operate on natural gas, the Mars 100 offers a cleaner-bu ...
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
used
34 MW Kawasaki Gas Turbine Overview A well-maintained, low-hour 34 MW gas turbine cogeneration power plant is available for acquisition. The facility commenced commercial operation in August 2021 and has accumulated approximately 13,298 operating hours as of May 25, 2023, with projected total operating hours of approximately 20,000 hours by March 2024. The plant will be available for delivery beginning July 2026. Designed for high-efficiency combined heat and power (CHP) applications, the facility incorporates a Kawasaki L30A gas turbine, heat recovery steam generation system, and steam absorption chiller, delivering excellent overall thermal efficiency while maintaining low emissions through Dry Low Emission (DLE) combustion technology. Plant Highlights Commercial operation date: August 2021 Manufacturer: Kawasaki Heavy Industries, Japan Manufacturing year: August 2020 ...
used
Kawasaki Gas Turbine Cogeneration Power Plant 34 MW / 60 Hz This modern 34 MW Kawasaki L30A Gas Turbine Power Plant is a highly efficient and environmentally friendly cogeneration facility designed for industrial and utility-scale power generation. Manufactured in 2020 and maintained in excellent condition, the plant combines reliable electrical generation with heat recovery, achieving total fuel utilization efficiency of up to 85.5%. Operation was stopped on Stopped in March 2024 in good condition and the plant was preserved with KHI’s maintenance instructions. The plant is powered by a Kawasaki L30A two-shaft industrial gas turbine featuring a 14-stage axial-flow compressor, advanced Dry Low Emission (DLE) combustion system and high-efficiency turbine technology. The unit delivers approximately 34 MW electrical output with thermal efficiency exceeding 41%, while maintaining exce ...
used
Mitsubishi Heavy Industries Ltd Type - SC1F ( Single Cylinder Single Flow ), Condensing Steam Turbine Power : 205.440MW HP Steam : 85 ata, 538 C LP Steam : 5.5 ata 193 C Steam Turbine Generator Model : MB-H Power - 241, 680 KVA Voltage - 16.5KV, 50 Hz
used
Centrax Gas Turbine-Generator Package - (USED) 50Hz Fuel Description Bio Gas Only Unit type M2000 KB5S Running hours 126701 Starts 2950 Megawatt hours 349558.0 mwhr Turbine speed 14580 RPM inspection report available
used
INDUSTRIAL GAS TURBINE Brand: Rolls-Royce Model: 501-KB5s-DLE Maximum pressure: 1,205 PSI Condition: Pre-owned / Overhauled : Industrial Equipment Operational Period: 1999 - 2011 Total Running Hours: 39,500 hours Documentation: I am reviewing the documents and will send you the key details shortly
used
Model: Avon 1533-56L Year of Manufacture: 1992 Type: Aeroderivative Gas Turbine Rated power: Approximately 16,347 kW (22,225.73 hp) to 17,007 kW (23,123.08 hp) DIRECTINDUSTRY Thermal Efficiency: Up to 44% Dimensions: Length: Approx. 3,200 mm Diameter: approx. 907 mm Weight: Approximately 1,310 kg
used
Capacity: 3,224 kW Volts: 400 HZ: 50 Condition: Very Good Scope of Supply: Complete Turbine Power Station with turbine and alternator, Control Panel, Condensor, Cooling Towers, Spilling Unit, Switchgear, Synchronisation panel, Transformer, Piping / wiring / pumps. Total cost for power plant components was around 3 million on the actual power plant components. Nominal Steam requirement to run the turbine is 17, 5 t/h at 29 barg & 350 °C. Available for sale from Gas Engine Exchange . Please check our full range of equipment at gasengineexchange.com.
used
Centrax 501 KB57 DLE Gas Turbine-Generator Package engine overhaul in 2017 at 24 000 hours 372 start service hours 23 000
used
APE gearbox (Dualbox) geabox Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm
Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Total weight: 1000 kg
used
Turbine power 330 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Turbine power 294 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Siemens steam turbine 3,370 kW nominal output. Speed: 11,500 r/min, live steam 80 bar, live steam 500 °C.
used
gas turbine Turbomeca MAKILA TI POWER 1 MWe year 2000 hours 6400 Soundproof turbine box,
used
Manufacturer: Siemens Model: SST-060 Year of Manufacture: 2016 Output Power: 1006 kW (nominal) Speed: 1500 rpm (nominal) Trip Speed: 1605 rpm Live Steam (Inlet Pressure): - Min: 20.6 bar - Nominal: 23.0 bar - Max: 25.4 bar Live Steam (Inlet Temperature): - Min: 300 °C - Nominal: 350 °C - Max: 378 °C Exhaust Steam (Outlet Pressure): - Min: 2.10 bar - Nominal: 3.10 bar - Max: 4.10 bar Exhaust Steam (Outlet Temperature): - Max: 331 °C Find more here - .ucymachines/ Contact us at - sales@ucymachines
used
Manufacturer: KKK Model: CF 5 G Year of Manufacture: 1986 Output Power: 412 kW Inlet Steam Pressure: 19 bar (Normal) Outlet Steam Pressure: 3 bar (Normal) Inlet Steam Temperature: 300°C (Normal) Alternator Features: Brand: AVK Alternator Type: DKBN80/500-4TS Power: 482 KVA (400 V, 696 A, 50 Hz) Year of Manufacture: 1986
used
Turbine Control Woodward 505 Turbine control, built in 2007 of 2600 KW Condensation turbine with 0 operating hours 1 available. 3.3 KV / 100 V, 50 Hz, 626 A Price: 6,900 €, plus VAT, FCA-free. Turbine Control Woodward 505 Manufacturer: Woodward Type: Turbine Control Rated power [KVA]: 3,575 Voltage [V]: 3.3 KV / 100 V Frequency [Hz]: 50 Operating voltage [V]: 24 Rated voltage [A]: 626 Year of Make: 2007 Dimensions [m]: 1.60 x 0.60 x 2.00 Weight [kg]: 500
used
GAS TURBINE CENTRAX PACKAGE OR ONLY CORE YEAR 1990 HOURS 40 000 PRICE LOADED IN FRANCE
new
1. Equipment Overview Equipment: Siemens SGT-500 Gas Turbine Packages Quantity: Two (2) units available Condition: New Surplus / Zero Operating Hours Manufacturing & Storage: Manufactured in 2007 Never operated – zero operating hours Preserved and stored according to OEM preservation procedures Originally supplied for a cancelled FPSO project Certification: Marine Rated DNV (Det Norske Veritas) Certified 2. Gas Turbine Technical Data Model: Siemens SGT-500 Configuration: Single-shaft industrial gas turbine Fuel: Dual Fuel (Natural Gas / Diesel) Frequency capability: 50 / 60 Hz ISO Power Output (Indicative): Natural Gas: approximately 17.4 MW Diesel: approximately 17.0 MW Performance: Specific Fuel Consumption: Natural Gas: 221 g/kWh Diesel: 262 g/kWh Heat Rate: Natural Gas: 11,066 kJ/kWh Diesel: 11,200 kJ/kWh ...
used
12mw steam turbine major overhauled end 2022 only runs for 1 year till end 2024
used
Unused Dresser-Rand Steam Turbine Generator Package – Never Commissioned Dresser-Rand Steam Turbine Available for immediate sale is a never-installed, never-operated Dresser-Rand steam turbine, manufactured in 2009. This unit has remained unused since manufacture and includes the original drawings and documentation. Steam Turbine Specifications Manufacturer: Dresser-Rand Year: 2009 Condition: Unused – Never Put Into Service Maximum Steam Inlet: Flow: 500 KPH Pressure: 925 psig Temperature: 750°F Maximum Extraction: Flow: 31 KPH Pressure: 352 psig Temperature: 543°F Exhaust Configuration: Up Exhaust for Condensing Outlet Documentation: Includes original drawings and documentation Brush Generator Paired with the turbine is a Brush generator, also unused and never commissioned. Generator Specifications Manufacturer: Brush Voltage: 13.8 kV Frequency: 60 ...
FOR SALE GAS TURBINE Tempest SGT300 packaged 7941 kva year 2000 50 HZ VOLT 11 000
hello for sale 2 units turbine in trailer Technical Specifications Model: Rolls-Royce Allison 570KA Year of manufacture: 2005 Fully overhauled: 2012 Commissioned: 2016 Operating hours since 2016: Only 81 hours Fuel type: Gas Power output: 4,400 kW Mounted on trailer: Yes Additional trailer: UPS trailer included Location: Paris, France loaded now Availability: Immediate Documentation: Complete (technical & maintenance records)
used
GAS TURBINE PACKAGE – GE LM 6000 PD 48 MW 1. General Information Equipment: Industrial Gas Turbine Package Manufacturer: GE Model: LM 6000 Year: 2002 Hours : 38 000 Condition: Used – Good Operating Condition loaded in france
used
3 Allison Turbine Detroit Diesel Allison Type 501 KB Year of manufacture 1980 alternator RATED 3860KW alternator DUTY 3355KW Alison turbine = 4380 HP --> domestic fuel oil INPUT RPM 14210 OUTPUT RPM 1500 Number of hours 600H of operation 10 KV cell (alternator output) Deutz 160 HP diesel (turbine launcher) 10 kW generator set – Deutz engine (Auxiliary power)
used
Type 501 KB Year of manufacture 1980 alternator RATED 3860KW alternator DUTY 3355KW Alison turbine = 4380 HP --> domestic fuel oil INPUT RPM 14210 OUTPUT RPM 1500 Number of hours 600H of operation 10 KV cell (alternator output) Deutz 160 HP diesel (turbine launcher) 10 kW generator set – Deutz engine (Auxiliary power)
used
FOR SALE CORE TURBINE CENTRAX 501 KB5 I don't have any more information since the factory has closed LOADED NOW IN FRANCE GOOD PRICE
used
A total of five identical Vestas wind turbines are expected to be available from early 2027. Rated power: 850kW, rotor area: 2124m², rotor blades: 3, rated speed: 26rpm, generator voltage: 690V, gearbox stages: 3, cut-in wind speed: 4m/s, rated wind speed: 16m/s, cut-out wind speed: 25m/s, tower material: steel, hub height: 74m, nacelle weight: 22t, rotor weight: 10t. Documentation available. An on-site inspection is possible. Individual sale possible.
new
Titan T250 Specifications Condition New / Never Used Status Disconnected. Preservation inspection was done in the Fall of 2020 and another inspection in 2022. Manufactured Solar Turbines 2017 Driver Solar Turbines Titan 250 Natural Gas Turbine / Version 30002S CS/MD Max HP 30,000 HP Rated RPM 10,500 RPM Control Panel Solar Turbotronic CTLM02
used
For sale loaded now departure france Used Solar Gas Turbine Mars 100 SoLoNOx Natural Gas Location: france loaded now Year of manufacture: 2012 Output Power: 11,350 kWe Heat Rate: 10.935 kJ/kWe-hr (10.365 Btu/kWe-hr) Exhaust Flow: 153,245 kg/hr (337,950 lb/hr) Exhaust Temperature: 485 °C (905 °F) Frequency: 50 Hz Package hours: 27206 Gas turbine hours: 20547 Number of starts: 216 Housed on skid installed indoor with attenuating enclosure and fire detection and suppression system. Inlet System Barrier Filter and Silencer mounted on ancillary skid on the roof of the enclosure. Gear Reduction Box RENK MAAG GmbH. Type: GPF3-28, Output Speed/Freq. 50Hz - 1500rpm Generator Data: Electric Brushless AC Generator with Permanent Magnetic Alternator. Alternator data: 2.2kW. PF.9. 1 Phase. 240V/10A/120Hz. Gen Skid includes Lube oil tank, pumps, filters, start system with AC D ...
used
GE Oil & Gas Nuovo Pignone Steam Turbine – Model SC1-10 For sale: Industrial Steam Turbine manufactured by GE Oil & Gas (Nuovo Pignone). Model SC1-10 (Equipment Tag: 661-KT-4101). This equipment is decommissioned and ready for transport. Ideal for power generation or as a mechanical drive for heavy-duty industrial compressors in refining, petrochemical, or power plants. Key Specifications: Manufacturer: GE Oil & Gas / Nuovo Pignone Equipment Type: Steam Turbine Model: SC1-10 Equipment Tag: 661-KT-4101 Condition: Used / Decommissioned. Location: Spain Status: Ready for immediate dismantling and transport. Please contact us for more information, technical datasheets, performance curves, or to arrange a site inspection.
used
GE Nuovo Pignone Backpressure Steam Turbine – Model SNC1-2 For sale: Industrial Backpressure Steam Turbine manufactured by GE Oil & Gas (Nuovo Pignone). Model SNC1-2 (Equipment Tag: 661-KT-3301). The equipment is decommissioned and prepared for safe transport. Ideal for mechanical drive applications or cogeneration in industrial plants, refineries, and petrochemical facilities. Key Specifications: Manufacturer: GE Oil & Gas / Nuovo Pignone Equipment Type: Backpressure Steam Turbine Model: SNC1-2 Equipment Tag: 661-KT-3301 Condition: Used / Decommissioned. Location: Spain Status: Ready for immediate dismantling and transport. Please contact us for more information, technical datasheets, performance curves, or to arrange a site inspection.
The plant was shut down in 2024 and has 19,900 hours of use. It has been operating at around 19-21 MW/h LM2500 plant, including dismantling and logistics management, with immediate delivery. The plant was shut down in 2024 and has 19,900 hours of use. It has been operating at around 19-21 MW/h Power Output: 22 MW 25,759 KVA x 0.80 (50 Hz) 11,000v (It can be adapted to 60 Hz) Working Hours: 19.900 Number of starts: 215 Last Start: Jun 2024 Control Panel: Woodward Micronet and Bently Nevada Auxiliary Systems: Included Available documentation: work history, MTU review, single-line diagrams, manuals, periodic inspections. Complete control room with Woodward Micronet control units, Bentley Nevada vibration monitoring, ABB protection relays, and Siemens HMI. Gearbox and alternator -- ABB 50/60 Hz, 11,000V Filter box and enclosure.
used
Siemens SGT-400 Gas Turbine Package – Year 2017 1. Offer Subject We are pleased to offer for sale a Siemens Energy SGT-400 gas turbine package, manufactured in 2017, in excellent operating condition and available immediately for power generation or industrial applications. 2. Technical Specifications Equipment Offered: Make/Model: Siemens SGT-400 Year of Manufacture: 2017 Type: Natural Gas Turbine Operating Hours: 42,000 hours Output Voltage: 11,000 Volts Frequency: 50 Hz Rated Power Output: Approximately 12 MW Condition: Used – Good operating condition Availability: Immediate This turbine package is suitable for reliable and efficient power generation, cogeneration, or industrial applications.
used
196 MW ABB Gas Turbine Power Plant consisting of four (4) gas turbine generator units complete with Balance of Plant. The equipment is owned by the seller and is currently installed in the United States. Equipment Summary Manufacturer: ABB Models: GT11C / GT11D Quantity: Four (4) Gas Turbine Generator Units Total Installed Capacity: 196 MW 3 × ABB GT11C – 48 MW each 1 × ABB GT11D – 52 MW Generator Frequency: 60 Hz Generator Voltage: 13.8 kV Speed: 3,600 RPM Air-cooled generators with brushless excitation Complete Balance of Plant included Single GSU transformer included Operating History The units have been operated in peaking service with relatively low fired hours: Unit 1 – GT11C, 48 MW – 829 Starts / 3,595 Fired Hours Unit 2 – GT11C, 48 MW – 788 Starts / 3,496 Fired Hours Unit 3 – GT11C, 48 MW – 875 Starts / 4,420 Fired ...
maximum number of results exceeded