We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
120,859 used machines on RESALE, but how to find them? Machine Search
maximum number of results exceeded > 1000
please refine your search
used
Plate Heat Exchanger,stainless steel,Sondex type S15/1G,15 plates
used
Plate heat exchanger,stainless steel,Pasilac type H17 RK-6 no.1,17 plates
used
Plate heat exchanger,stainless steel,APV type H17 RK-6 no.1,23 plates
used
Plate heat exchanger,stainless steel,APV / Pasilac type 1070 EKSB
used
Plate heat exchanger,stainless steel,DDMM type 1070
used
Plate heat exchanger,stainless steel,APV type N35,13 plates
Plate heat exchanger,stainless steel,Alfa Laval type P2
used
Plate heat exchanger,stainless steel,Alfa Laval type M6
used
Plate heat exchanger,stainless steel,Alfa Laval type P0
used
Plate heat exchanger,stainless steel,APV H17,painted edge-clamped wall fitting
used
Plate heat exchnager,stainless steel,Alfa Laval P01,painted,edge-clamped. 7 plates
used
Plate heat exchanger,stainless steel,Alfa Laval P01,painted edge-clamped. 9 plates.
new
7pcs Zeta REV HP XT 18.4 master-slave control 1 piece Zeta REV HP XT 12.4 Zeta REV HP XT 18.4 / EC 1P - hydraulic module with one pump LN - Soundproofed RUB - Shut-off valves compressors BC - Storage capacitor for electronic expansion valve VEC - EC Fans FVP - Flowzer VP FVDE - FLOWZER VDE RA - Antifreeze Heater PBA - BaCnet™ protocol on TCP-IP FM6 - Multilogic function for master with management of up to 6 slaves 1 of 7 and 7 slave SETV - Variable setpoint shift above 0-1V, 0-10V, 0-4mA or 0-20mA Signal RMMT - Voltage Monitoring IACV - Circuit breakers for Compressors and fans A43 - Power supply 400/3/50 AG - Rubber vibration dampers RAV - Antifreeze heating resistor for Condensate collection basin and Zeta REV HP XT 12.4 / EC 1P - hydraulic module with one pump LN - Soundproofed RUB - Shut-off valves compressors BC - Storage capacitor ...
used
Plate heat exchanger,stainless steel,Pasilac type N35 MGS,102 plates
used
Tube heat exchanger,stainless steel,with Ø 22 mm. tubes,cabinet Ø 500 x L 3000 mm.
used
Tube heat exchanger,stainless steel,with 30 mm spiral tube,outer dimension D 260 x L 2810 mm.
used
Tube heat exchanger,stainless steel,with 20 mm. tubes,outer dimensions D 375 x L 3050 mm.
used
Water tanks, extinguishing water tanks and heating oil tanks USED & RECONDITIONED Muensterlandtanks.de Container and tank trading Call us: 0162 1341979 A used heating oil tank according to DIN 6616 in the size of 30,000 Ltr. is offered. Volume: 30.000 Ltr. Material: Steel tank tank, material S235JRG2 Tank according to DIN 6616 Tank shape: cylindrical, horizontal, in integrated trays, double-walled Diameter 2.0, L approx. 10.50 m Exits: Dom on the top Tank according to DIN 6616 for above-ground storage of heating oil and diesel Tank technology equipped with: lid, filling nozzle, ventilation nozzle, dipstick, suction line, truck filling nozzle, limit value transmitter and leakage indicator Tank is in top condition Delivery time approx. 1 week (transport organization). The tank can be inspected at my premises. Location Ascheberg. Transport can be arranged cost-e ...
used
Tube heat exchanger,stainless steel,Spiraflo Monotube,Ø 2" x L 3000 mm.
used
Tube heat exchanger,stainless steel,20,4 m2 heating surface,Ø 13 mm tubes.
used
Tube heat exchanger,stainless steel,OY Sanatasalo Sohlberg AB.
used
Water tanks, extinguishing water tanks and heating oil tanks USED & RECONDITIONED Muensterlandtanks.de Container and tank trading Call us: 0162 1341979 A used heating oil tank according to DIN 6616 in the size of 80,000 litres is offered. Volume: 80.000 Ltr. Material: Steel tank tank, material S235JRG2 Tank according to DIN 6616 Tank shape: cylindrical, horizontal, in integrated trays, double-walled Diameter 2.90, L approx. 12.80 m Exits: Dom on the top Tank according to DIN 6616 for above-ground storage of heating oil and diesel Tank technology equipped with: lid, filling nozzle, ventilation nozzle, dipstick, suction line, truck filling nozzle, limit value transmitter and leakage indicator Tank is in top condition and is immediately available. Delivery time approx. 1 week (transport organization). The tank can be inspected at my premises. Location Ascheberg. ...
used
Tube heat exchanger,stainless steel,total area 6 m²
used
Tube heat exchanger,stainless steel,coil in cabinet Ø 12 x L 25000 mm
used
Heat blower,Dehumyd type PR3,440 W,220 V.
used
Pasteur 500l/h Gas newly overhauled automatic temperature control
new
DeDietrich oil boiler QUANTROL Temperature Controller Tube in tube heat exchanger LIVERANI Stainless Steel Impeller Pump Pre-installed mobile complete system with impeller juice pump, efficient boiler, heat exchanger and automatic control, consisting of: Chassis mounted on 2 fixed and 2 swivel castors 63kW boiler with oil burner circulating pump Pressure expansion tank Automatic temperature control Tube in tube heat exchanger Capacity 750l juice /h Oil consumption: approx. 6l/h at full load
Tube heat exchanger,stainless steel,with Ø 20 mm tubes,cabinet Ø 350 x L 2700 mm.
used
The Cabero heat exchanger with model number AC/VNC065SC/2L is a high-quality heat exchanger designed for various industrial applications. It has a test pressure of 32 bar and an operating overpressure of 28 bar, making it a robust and reliable system. This heat exchanger is made of high quality materials and is designed to operate under demanding operating conditions. It offers a high heat transfer rate and is able to transfer large amounts of heat efficiently. The Cabero heat exchanger with model number AC/VNC065SC/2L is easy to install and maintain and offers a long service life. It is equipped with a number of features that ensure its efficiency and reliability, such as a robust housing that offers excellent protection against environmental influences. Overall, the Cabero heat exchanger with model number AC/VNC065SC/2L is an excellent choice for anyone who needs reliable and ...
new
Heat pump / chiller air-cooled, switchable, reversible Type: HCYGNUS TECH HCY 171 PT1 MTA S.P.A. CYGNUS TECH HCY 171 PT1 are compact heat pump / water chillers suitable for outdoor installation up to -10°C suction temperature. Includes crank tub heating, buffer tank, built-in P1 circulation pump. Cooling capacity kW 36.5 Cold water temp. Outlet / Inlet: 7 / 12°C Volume flow m³/h 6.21 Available pump pressure bar 1.85 Ambient temperature °C 32 Heating capacity kW 43.2 Heating water temp. Outlet / Inlet: 45 / 40°C Volume flow m³/h 7.52 Available pump pressure bar 1.46 Ambient temperature °C 7 Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 power consumption (kW) 18,91 current (A) 33.67 Starting current circuit (A) 201.37 Protection class: IPX4 Dimensions: Depth mm 2104, width mm 1112, height mm 1477 Weight kg 620 C ...
new
Heat pump / chiller air-cooled, switchable, reversible Type: HCYGNUS TECH HCY 171 PT1 MTA S.P.A. CYGNUS TECH HCY 171 PT1 are compact heat pump / water chillers suitable for outdoor installation up to -10°C suction temperature. Includes crank tub heating, buffer tank, built-in P1 circulation pump. Cooling capacity kW 36.5 Cold water temp. Outlet / Inlet: 7 / 12°C Volume flow m³/h 6.21 Available pump pressure bar 1.85 Ambient temperature °C 32 Heating capacity kW 43.2 Heating water temp. Outlet / Inlet: 45 / 40°C Volume flow m³/h 7.52 Available pump pressure bar 1.46 Ambient temperature °C 7 Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 power consumption (kW) 18,91 current (A) 33.67 Starting current circuit (A) 201.37 Protection class: IPX4 Dimensions: Depth mm 2104, width mm 1112, height mm 1477 Weight kg 620 C ...
new
New oil tank 100,000 liters for sale. Above-ground heating oil tank system 100,000 litres, D=2,900 mm Above-ground tank systems from Dehoust according to EN12285-2 (CE), class B, tank type D, for heating oil. Cyl. Storage tank made of steel, double-walled, with filled control liquid Glymin NF (approval no. BAM 1.4/12481-5.1/6035). Standard with a Dom DN 600 with dome cover, gasket and screws. Container inside raw, outside all parts sandblasted and with simple primer. Incl. synthetic resin paint on the outside in RAL colour. Complete tank system equipped with: - welded-on saddle feet - optical leak detector type LAS, approval no. Z-65.24-381 including Test and control liquid for refilling. (up to Ø2000mm pre-assembled) - Tank fitting for heating oil (pre-assembled up to Ø2000mm), consisting of: Filling tube 2" with TW closure Suction combinatio ...
used
max. temperature: 420 Grad size of opening: 200 mm depth of chamber: 350 mm total power requirement: 2,5 kW weight of the machine ca.: t dimensions of the machine ca.: m The data for this ad was created with ModulMWS - the software solution of LogoTech oHG.
new
CLIMAVENETA AWR-MTD2-XE.0031MS Brand:CLIMAVENETA Type:AWR-MTD2-XE.0031MS Stock number:M23-4626 Cooling capacity:9.2 kW Application:Cooling / Heating Number of fans:2 Refrigerant:R410A Refrigerant Content:3,5 kg Voltage:220 Volts Power consumption:5,19 kW Dimensions:900 x 420 x 1240 mm Weight:155 kg Year: New/unused Number in stock:3 piece(s) Price:Quotation request Description: New unused air-cooled Climaveneta water chiller/heat pump with a scroll compressor, water pump and expansion vessel. This machine is equipped with a separate control unit. Mentioned capacity at a water temperature of +12/7°C and an ambient temperature of +35°C. (Heating: Q= 12,3kW at +40/45°C and +7°C). Visit our website: used-refrigeration
used
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protection Class: IPX4 Dimensions: Depth mm 550, width mm 1420, height mm 1288 Weight kg 197 Connection Rp 1" Serial No.: 2200371602 Year of construction: 2021 Condition: Optical 2, Technically ok us ...
used
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protection Class: IPX4 Dimensions: Depth mm 550, width mm 1420, height mm 1288 Weight kg 197 Connection Rp 1" Serial No.: 2200371602 Year of construction: 2021 Condition: Optical 2, Technically ok us ...
used
1 complete ready-to-use WEHO hot air heater operated with heating oil, immediately available from the site for self-dismantling
W&H Block bottom heat seal machine for air sickness bags
used
Tube heat exchanger,stainless steel,with Ø 20 mm tubes,cabinet Ø 350 x L 2700 mm.
used
complete 230kW
used
M. No.: 12091 Equipment / Additional information: DESCRIPTION: The sealers Pactur thanks to their production concepts, can be easily transported. The electronical control grants good performances and user friendly functioning. Although they have a limited foot print, are equipped with a real shrink tunnel, which grants high packaging perfomances and excellent results. The machine has two conveyor belt movement cycles, choiceable from the control panel: forward-forward and forward-reverse. Forward-Forward, with product outflow from the side opposite the load, for greater productivity. Forward-Backward, with product return to the operator, for fragile products or logistical needs. SECTORS OF USE: Pharmaceutical, chemical, cosmetics, food, dietary, medical devices, manufacturing. MAIN FEATURES: Semi-automatic sealer with shrinking tunnel Pactur type Lady Pack 45/SL 2 includ ...
used
Heating elements used in Kisters ZVT and ZEVA shrinktunnels. Various quantities and lengths (600, 700 and 1000 mm) and types (straight, bent, with and without wires) available: 240, 290 and 347 Volts, 2150, 3100 and 3500 Watts.
used
We offer for sale two pieces MWM TBG 616 V8 K.. Technical data engine: Engine manufacturer: MWM Engine type: TBG 616 V8 K Rated power: 300 kW Speed: 1500 rpm Fuel: Natural gas Technical data generator: Generator manufacturer: Stamford Generator power: 600 KVA Voltage: 400 / 231 Volt Power factor: cos. - phi 0.8 Speed: 1500 rpm Year of construction: 2004 Operating hours: 57,000 h Location: Cologne
used
We offer a Liebherr G944 for sale.
used
We offer for sale a piece mwM TBG 616 V 8 K. Technical data engine: Engine manufacturer: MWM Engine type: TBG 616 V 8 K Rated power: 350 kW Speed: 1500 rpm Fuel: Natural gas Technical data generator: Generator manufacturer: Stamford Generator power: 550 KVA Voltage: 400 / 231 Volt Power factor: cos. - phi 0.8 Speed: 1500 rpm Year of construction: 1996 Location: Cologne
used
Pipe heater, pipe burner, pipe construction burner -Max. Diameter: 250 mm -Burner for steel pipeline construction -Propane -Transport box -Dimensions: 600/1400/H330 mm -Weight: 90 kg
used
mobile heating system, central heating system, steam heating, land steam boiler system used STEAG / GVT Saarbrücken Boiler capacity: Steam 5 t/h Boiler manufacturer: BABCOCK / OMNICAL Boiler type: OMNIMAT Temp. max 190°C Pressure max 13 bar Boiler capacity 6080 l OIL / Gas Burner WALKER RGL50/2-A YOC:2004 5400 kW Gas type N Heat and soundproofed container 11 x 3.6 x 3.9 m Transport weight: approx. 30 t Operating weight approx. 44 t Electrical power requirement 25 kW The plant has not been in operation since 04.2020 and has been preserved dry.
used
Heating burner, bitumen burner, flame device -complete with hose and regulator
used
mobile heating system, central heating system, steam heating used STEAG / LOOS Boiler capacity: steam 3.2 t/h Boiler manufacturer: LOOS Boiler type: UHD 3200 Temp. max 190°C Pressure max 13 bar Boiler capacity 2650 l Burner WALKER D112/140-2 7.0 kW Heat and soundproofed container 9.2 x 3.6 x 3.6 m Transport weight: approx. 25t Operating weight approx. 30 t Electrical power requirement 25 kW Changes and errors in the technical data, information and prices as well as prior sale reserved.
used
USED IRON 25 M2 BACHILLER TUBULAR EXCHANGER REF#: C9444 Tubular exchanger manufactured by BACHILLER with an exchange surface of 25 m2 General characteristics: Manufactured by BACHELOR Material Iron Year built 1996 Weight 4300 kg Shell Tubes Pression de conception 8 bar 8 bar Température de conception 300 ºC 180 ºC Test pression 20.7 bar 15 bar Volume 285 L 195 L Technical characteristics: Exchange surface 15 m2 Tubes passes 2 Casing passes 1