We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
126,675 used machines on RESALE, but how to find them? Machine Search
used
1300 KW KK&K CFR3 G5A tandem condensing steam turbine 40 bar inlet pressure from 1997 with 50.000 running hours in very good working condition for sale. Scope of supply: controlpannel, turbine with generator, documents. turbine: KK&K type: CFR3 G5A el. power: 1300 KW steam inlet pressure: 40 bar manufactured: 1997 generator: AEM type: SE 500 M4 powerrating: 1830 KVA volts: 400 volts Hz: 50 Hz price on request: Stromerzeuger-Discount.com Kürtener Straße 13 D-51465 Bergisch Gladbach Mobile: 00491635263546 Telefon: 0049 2202 2492256 Fax: 0049 2202 2492257 Email: info@stromerzeuger-discount.de
used
Turbine Turbine operating hours: 30,000h Backpressure turbine Manufacturer: Kkk First start-up: 2002 Type: CFR5 G6a Power max: 2500 kW Operating efficiency: 2200 kW, Number of revolutions: 23000 rpm, Live steam pressure: 65 bar, Live steam pressure temperature: 480 C, Evaporation pressure: 1-17 bar, Investments in 2002 , Entire steam transformation station renewed from 63 bar to 2.5 bar in 2002, El. Generator Fa. Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA, renewed, complete measurement, control and control of the turbine renewed, steam turbine renewed with energy production General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic corder and ash removal system renewed, water treatment plant renewed, complete instrumentation renewed, flue gas cleaning plant Lurgie renewed from 1991 - 2001 Mistakes excepted!
used
51 MW - CCGT comprising 3 x 12 MW Solar Gas Turbine generator and 1 x 15 MW steam turbine generator Model : TITAN 130 Capacity : 12 MW Voltage ; 11 KV / 50 Hz Qty : 3 sets Titan 130 + 1 set STG Year : 2012 Running hr : 6000 hrs since new
used
Complete 48 MW Westinghouse W251-B11A Gas Turbine with a Brush electric generator, 3000 rpm, 50 HZ, 11.5 KV, may be modified as Dual Fuel GT ied
used
3692 KW Dresser Tuthill Nadrowski Tandem Condensation Turbine (steam turbine)for sale. 58.000 € plus VAT FCA freely charged in D-Bergisch Gladbach. Scope of supply: Steam turbo set and generator (6 KV). On request, generators with 10 to 11 KV are also available. A suitable capacitor costs 75,000 € extra. Not included: Control. Brand: Leroy-Somer Manufacturer: Tuthill Nadrowski Turbinen GmbH Type: LSA 56 BS 5- 4P Serial No.: 168233-1 Year of construction: 12-2001 Electr. Power: 3692 KW Power: 4625 KVA Voltage: 6000 V rpm: 1500 rpm Size (L x W x H): 3.10 m x 1.80 m x 2.70 m Weight: 10,000 kg Total output HD and ND turbine: 3692 KW. Total weight steam turbo set: 15 tons + 10 tons generator.
used
Solar Gas turbine Taurus 65 SOLONOX The turbine and gear box is from 2022 and it only has 2000 running hours. The package is from year 2011. The condition is excellent and is ready to start working, in addition it included Solonox mode and fire extinction module. All the maintenance has been done by Turbomach official service. The equipment is already dismounted on our warehouse and ready to be load. It is available all the systems except the exhaust system that is optional. It is possible to have a visit and a inspection of the turbine. Also is available a boroscope of the turbine. YOM:2022 Power: 6300kWe Fuel: Natural Gas Working Hours: 2300 h Voltage: 6300V
used
2 used steam turbine units available: 1. Type: B5 S2 + G IV Year: 1991 Turbine output: 294 kW at 1.35 bar and 170 C With exhaust gas heat exchanger 2. Type: B5 S3 + G IV Year: 1992 Turbine output: 330 kW at 1.35 bar and 170 C With exhaust gas heat exchanger Subject to prior sale - Errors possible
used
MAN NR34/S026 Turbocharger 1 new and 3 used available New bearings and repair sets also available in our stock in Istanbul Please contact: info@fin-marine
new
Elster SM-RI-X-E G1600 Turbine Wheel Gas Meter Elster Turbine Wheel Gas Meters SM-RI-X-E-G1600-200-98.5-K (170) Qmax: 2500 m³/h Qmin: 130 m³/h pmax: 89.5 bar Item #: 10520813-2014 Pulse generator HF2 162,370 Imp/m³ Regular price: 21.540,-€ net
used
1 piece ABB TPL 77-B12 turbocharger complete available New In our stock in Istanbul Please contact: info@fin-marine
used
used
Kawasaki M7A-03D 7.2MW Natural Gas Turbine Complete CHP Generating Set Completely self-contained Kawasaki M7A-03D 7.2MW Gas Turbine and Generator package with Heat Recovery (Thermic Fluid Heater and HRSG Hot Water Generator) in acoustic enclosure. Runs parallel with grid. Island operation mode. Make and Model: Kawasaki TD80A Capacity: 7200kW Hrs: 10,000 V: 11,000 HZ: 50 Year: 2010 Fuel: Natural Gas Scope of supply: Gas Turbine GPB 80, M7A-03 DLE Single Gas Fuel, single shaft with DLE Combustor, reduction gear box, coupling with guard, Diaphragm Type, Generator (TD80A, 2011) Heat Recovery System - Thermic Fluid Heater, HRSG Hot Water Generator Acoustic Canopy with Lighting Control and Instrumentation Exhaust collector and/or diffuser, Gas Fuel system, Lube oil system, Inlet ducting, Inlet filtration system, Inlet silencer, Combustion system, Protection system ...
used
MBARBECOL turbine flap PN-5478 MAN 28/32 engine Just the turbine hull.
used
Available in stock 1 x Used Capstone TET. The unit is used but in good working conditions. Note: We have several Capstone parts in our stock to sell. If you are looking for something in particular, please contact us and we will see if we have anything to fulfill your request.
used
Centrax ROLLS ROYCE 5 MW CX 501 KB7 Gas Turbine-Generator Package YEAR 2011 HOURS 40 000 Equipment List: Turbine/Alternator Housing and its complete contents including: • 1 Allison 501 KB7S DLE Gas Turbine - • 1 Alternator • 1 Epicyclic Gearbox • 1 Acoustic Enclosure • 1 Alternator Control Cabinet and Software • 1 Turbine Control Cabinet and Software • 1 Auxiliary Distribution Cabinet and Software • 1 Lubrication Unit including Oil Cooler • 1 Fuel Supply Circuit in Acoustic Enclosure • 1 Electro-Hydraulic Starting System- • 1 Compressor Cleaning System • 1 DC Power Supply • Battery Charger • Fire Protection and Gas Detection Circuit • Fan acoustic enclosure • Air cooler fan List of components: • Control/command panel and room and its complete contents • Filtration assembly and combustion air ducts • Filtration assembly, silencers and box ventilat ...
used
Turbogas Turbine GE5/1 5MW Natural gas for sale. Complete turbogas turbine plant with electric generator, recovery boiler and exchangers, dry cooler, diverter. Total Hours: 36,000 8,000 hours from the last overhaul. THERMAL POWER 9,0 MWt Saturated steam production 13,000 kg/h at 10BARg Voltage 11000 V Frequency 50 hZ Also available: - GE5/1 used turbine in nitrogen storage with 72,000 hours + 8,000 Hours after the last overhaul + one used generator Price: €240,000. - NEW GE5 Turbine Spare Parts (value 1 million) Price : €320,000. Available for sale from Gas Engine Exchange. Please check our complete range of equipment at gasengineexchange.
used
537 KW Tuthill Nadrowski back-pressure steam turbine C4. S-GIII from 2004, only turbine (was used as a pump). 1 available inlet pressure 90 bar, outlet pressure 18 bar, Price: € 19,500 each, plus VAT and FCA-free Manufacturer: TUTHILL Nadrowski Model: C4. S-G III Type: Steam Back Pressure Serial Number: 21004 Power [kW]: 537 Pressure inlet [bar]: 90 Pressure outlet [bar]: 18 Speed (rpm) 3.554 Year of construction: 2004 Weight [kg]: 2.440 Dimensions LxWxH [cm]: 370x138x174
used
Emergency power gas turbine from 1977 with few running hours, without generator and controller. 1 available 456 KW x 1,500 1/min Manafacture: Garrett Model No.: ME831-800A Type: Gas turbine Serial Number: P-830005 Power [KW]: 456 Year of construction: 1977 Weight [kg]: 915 Dimensions LxWxH [cm]: 270x120x120
used
TAURUS 70 Gas Turbine Year Of Make: 2004 Total running hours: 58.000h Total hours since last overhaul 28.600h Turbine 15158 RPM 60 HZ / 15143 RPM 50 HZ Alternator 1500 RPM 50 HZ 7200 Kw at 9000 KVa 11000 Volts
used
Kaplan turbine Escher Wass with standing shaft, used very good condition Gradient 7.00m-7.2 m Water volume 6000l/sec, power 500 hp, speed 375T/min
used
Taurus 60 Turbine Generator Set Solar Taurus 60 T7301 Gas Turbine Engine Runnig hour 1165 hour after last Overhaul Output Power 5200 Kw Gearbox Solar Gear Unit 1165 hour after last Overhaul Type: Epicyclic Leroy Somer Generator 50 Hz
used
GE LM 2500 gas turbines 2 pcs available Power:24.000 Hp each Average working hours 1700 hours
used
GE Model : LM6000PA Power Output : 42 MWe ISO condition Voltage : 11KV Frequency : 50Hz Total 2 nos.
used
Ansaldo Condensing Steam Turbine Power: 9000 kW RPM: 7500 / 1500 Steam pressure: 40bara Steam temperature: 420 ºC Back Pressure: 0,08bar Number of extractions: 2 Number of stages: 8
used
BVI / ThyssenKrupp Condensing steam turbine MARC6-C03 2005 power generator with 135,000 operating hours, without steam condenser and AC generator. Inlet pressure 89 bar, outlet pressure 0.11 bar, 21,000 KWel x 1,500 rpm, Steam turbine BVI / ThyssenKrupp MARC6-C03 Manufacturer: BVI / ThyssenKrupp Model No.: MARC6-C03 Type: Steam Condensation Serial number: P-900078 Power [KW]: 23,545 Pressure Input [bar]: 89 Temperature Input [°C]: 520 Pressure output [bar]: 0.11 Year of Make: 2005 Hours: 135,000 Weight [kg]: 58,000 Dimensions LxWxH [cm]: 510x400x340
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
used
Mitsubishi Heavy Industries Ltd Type - SC1F ( Single Cylinder Single Flow ), Condensing Steam Turbine Power : 205.440MW HP Steam : 85 ata, 538 C LP Steam : 5.5 ata 193 C Steam Turbine Generator Model : MB-H Power - 241, 680 KVA Voltage - 16.5KV, 50 Hz
used
Centrax Gas Turbine-Generator Package - (USED) 50Hz Fuel Description Bio Gas Only Unit type M2000 KB5S Running hours 126701 Starts 2950 Megawatt hours 349558.0 mwhr Turbine speed 14580 RPM inspection report available
used
INDUSTRIAL GAS TURBINE Brand: Rolls-Royce Model: 501-KB5s-DLE Maximum pressure: 1,205 PSI Condition: Pre-owned / Overhauled : Industrial Equipment Operational Period: 1999 - 2011 Total Running Hours: 39,500 hours Documentation: I am reviewing the documents and will send you the key details shortly
used
Model: Avon 1533-56L Year of Manufacture: 1992 Type: Aeroderivative Gas Turbine Rated power: Approximately 16,347 kW (22,225.73 hp) to 17,007 kW (23,123.08 hp) DIRECTINDUSTRY Thermal Efficiency: Up to 44% Dimensions: Length: Approx. 3,200 mm Diameter: approx. 907 mm Weight: Approximately 1,310 kg
used
Centrax 501 KB57 DLE Gas Turbine-Generator Package engine overhaul in 2017 at 24 000 hours 372 start service hours 23 000
used
Heating output: 42.8kW, tank capacity: 51l, fuel: heating oil, oil consumption: 3.63kg/h, blower output: 1600m³/h. An on-site inspection is possible.
used
APE gearbox (Dualbox) geabox Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm
Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Total weight: 1000 kg
used
core engine Centaur 50. The turbine and associated gearbox have been completely base overhauled after last operating and are a ready-to-install for a zero-hour turbine exchange. After the overhaul, there was no active operation / no installation. The turbine and gear box Sale Solar Centaur 50 Base overhauled core engine: Manufacturer Solar Turbines - Type CENTAUR 50 SoLoNox - Year of construction 2022 Zero-hour core turbine and gearbox - Electrical output 4,040 kWel - Speed 14,944 rpm 50Hz - Fuel Natural gas H - Design temperature 15° C - Turbine inlet temperature 665 °C (1.229 °F) - Gearbox with zero operating hours - Turbine control Solar TTS4
used
Turbine power 330 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Turbine power 294 kW at 1.35 bar and 170°C including exhaust gas heat exchanger
used
Details of the equipment offered: • 1 Rolls Royce Type 501K-2044 turbine – ASP Engine Model 501-KB7, with sound-absorbing box • 1 ALEN GEARS Type STAR speed reducer – ASG34 • 1 Leroy Somer LSA 56 BUL85-4p / 6750 KVA alternator – 50 Hz • Natural gas control system • Box ventilation system • Electrical control cabinet • Fire Suppression System • Flue gas and water recovery boiler • Compressed air control system Characteristics: • Year of manufacture: 1999 • Total hours of service: 43,000 hours • Equipment still in operation, maintenance monitored by the manufacturer • Loading from France Overhauled in 2023 Photos and video available on request: This package represents an interesting opportunity for any company looking for a reliable and immediately operational solution. Do not hesitate to contact us for any further information, ...
used
gas turbine Turbomeca MAKILA TI POWER 1 MWe year 2000 hours 6400 Soundproof turbine box,
used
GAS TURBINE CENTRAX PACKAGE OR ONLY CORE YEAR 1990 HOURS 40 000 PRICE LOADED IN FRANCE
used
SALES PROPOSAL GAS TURBINE PACKAGE – SOLAR TAURUS 70 1. General Information Equipment: Industrial Gas Turbine Package Manufacturer: Solar Model: Taurus 70 – 10302S CS/MD Stand Core Turbine Year: 2019 Package Year: 1997 Condition: Used – Good Operating Condition 2. Technical Specifications • Output: 8,500 kVA • Frequency: 50 Hz • Voltage: 11,000 V • Alternator: LS – 6,300 V • Fuel Type: Natural Gas 3. Operating Data • Total Package Hours: 14,517 hours • Number of Starts: 127 • Next Planned Major Overhaul: 30,000 running hours • Borescope Inspection: Completed in 2024 (report available upon request) 4. Key Advantages ✔ 2019 Core Turbine (recent upgrade) ✔ Low number of starts ✔ Recent borescope inspection ✔ Suitable for 50 Hz industrial power generation ✔ Natural gas operation 5. Commercial Terms • Availability: To be con ...
used
12mw steam turbine major overhauled end 2022 only runs for 1 year till end 2024
used
6.6 MW MAN THYSSEN Extraction Condensing Steam Turbine Manufacturer: MAN THYSSEN Year of Construction: 1999 Condition: Used – In Good Running Condition Availability: In Stock Technical Data: Rated Power Output: 6.6 MW Voltage: 11 kV Frequency: 50 Hz Steam Inlet Conditions: Pressure: 40 bar Temperature: 440 °C Extraction Performance: 6 MW with 50 t extraction – 65 t/h 6 MW with 16 t extraction – 45 t/h 5 MW with 0 t extraction – 28 t/h Extraction Steam: Pressure: 12 bar Temperature: 294 °C Exhaust Steam: Pressure: 0.25 bar Temperature: 65 °C Description: Well-maintained German manufactured extraction condensing steam turbine suitable for industrial power generation and combined heat and power applications. The unit is designed for continuous operation and is ideal for sugar mills, textile plants, paper mills, chemic ...
used
10 MW W H-ALLEN Bedford England Back Pressure Steam Turbine Manufacturer: W H-ALLEN, Bedford, England Type: Back Pressure Steam Turbine Condition: Used – In Good Industrial Condition Availability: In Stock Technical Specifications: Rated Power Output: 10 MW Rated Speed: 7,750 RPM Voltage: 11 kV Frequency: 50 Hz Steam Conditions: Inlet Steam Pressure: 44.8 bar g Inlet Steam Temperature: 400 °C Exhaust Steam Pressure: 1 to 5.2 bar g Heavy-duty British-manufactured back pressure steam turbine designed for continuous industrial power generation and process steam applications. This unit is suitable for combined heat and power systems in sugar mills, textile plants, paper mills, chemical industries, and other steam-based manufacturing facilities. The turbine operates at high efficiency with stable back pressure performance, making it ideal for facili ...
used
Manufacturer: KKK Model: AFA4 / AFA6 TWIN Year of Manufacture: 1997 Output Power: 1822 kW (maximum) Inlet Steam Pressure: 22.9 bar (minimum), 25.5 bar (normal), 28.1 bar (maximum) Outlet Steam Pressure: -0.5 bar (normal), 0.2 bar (maximum) Inlet Steam Temperature: 355 °C (minimum), 405 °C (normal), 415 °C (maximum) Outlet Steam Temperature: 275 °C (maximum) Generator Specifications: Brand: AEM Generator Type: SE 500 M4 Power: 2203 KVA (400 V, 3180 A, 50 Hz) Find more here - / Contact us at -
used
20 MW STAL-LAVAL Industrial Steam Turbine Generator Set Manufacturer: STAL-LAVAL (Sweden) Type: Industrial Multi-Stage Steam Turbine Configuration: Condensing / Extraction-Condensing Manufacturing Era: Circa 1963–1964 Condition: Industrial Condition – Available for Inspection Availability: In Stock Power & Electrical Data: Rated Output: Approx. 20 MW Frequency: 50 Hz Rated Speed: 3000 RPM Generator: STAL-LAVAL GTP Series Generator Poles: 2-Pole Turbo Alternator Cooling System: Radial-flow air ventilation with filtration Coupling: Direct-coupled turbine-generator set Steam Design Parameters: Steam Pressure Class: Approx. 65 bar Steam Temperature (Design): Approx. 480–520 °C Operating Mode: Condensing turbine with surface condenser (extraction capable) Exhaust System: Shell and tube surface condenser Technical Features: Curtis con ...
used
Manufacturer: KKK Model: CF 5 G Year of Manufacture: 1986 Output Power: 412 kW Inlet Steam Pressure: 19 bar (Normal) Outlet Steam Pressure: 3 bar (Normal) Inlet Steam Temperature: 300°C (Normal) Alternator Features: Brand: AVK Alternator Type: DKBN80/500-4TS Power: 482 KVA (400 V, 696 A, 50 Hz) Year of Manufacture: 1986
used
Turbine Control Woodward 505 Turbine control, built in 2007 of 2600 KW Condensation turbine with 0 operating hours 1 available. 3.3 KV / 100 V, 50 Hz, 626 A Price: 6,900 €, plus VAT, FCA-free. Turbine Control Woodward 505 Manufacturer: Woodward Type: Turbine Control Rated power [KVA]: 3,575 Voltage [V]: 3.3 KV / 100 V Frequency [Hz]: 50 Operating voltage [V]: 24 Rated voltage [A]: 626 Year of Make: 2007 Dimensions [m]: 1.60 x 0.60 x 2.00 Weight [kg]: 500
FOR SALE GAS TURBINE Tempest SGT300 packaged 7941 kva year 2000 50 HZ VOLT 11 000
used
maximum number of results exceeded