Paint booth
Manufacturer: Fig
Type: Fe 36 / 17000
Year of Make: 2019
Cleaning booth
Manufacturer: Fig
Type: Fe 450 / 7000
Year of Make: 2019
LACQUER:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 7,000 x 3,500 x 3,800 mm
Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
Three-phase current 400 V / 50 Hz
Exhaust fan (FU-controlled)
V = 17,000 m3/h, nominal power drive: 7.5 kW
Three-phase current 400 V / 50 Hz
Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 mbar
Pre-filter: G3 bags 200 mm
Ceiling filter: M5 EN 779
Exhaust air filter: folding carton filter and Paintstop
Current type motor: 3x 400 V / 50 Hz
LEL limit: < 10%
Paint shop: c = 0.15 g/m3 / LEL 0.38%
Drying operation: c = 1.52 g/m3 / LEL 3.80%
Basis of calculation: 3,000 kg / year with 41% LM content
Daily consumption: approx. 2.1 kg/h
Solvent quantity: 3,211 g/batch
CLEAN:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 6,000 x 3,500 x 3,800 mm
Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
of which 7,000 m3/h cleaning booth
Three-phase current 400 V / 50 Hz
Exhaust fan (FU-controlled)
V = 7,000 m3/h, nominal power drive: 3.0 kW
Three-phase current 400 V / 50 Hz
Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 M57388 mbar
Pre-filter: G3 bags 200 mm
Ceiling filter: M5 EN 779
Current type motor: 3x 400 V / 50 Hz
In the "Clean" area, the fresh air is supplied from the outside via
the supply air fan
and cleaned of coarse dust. The supply fan pushes this air
via the sewer line into the exhaust box. Before the heated fresh air
enters the
the cleaning booth is blown, a second filter is applied to the filter
ceiling
Filter stage in which the air is freed from fine dust. Afterwards,
the air into the washroom practically dust-free. The exhaust air from
the cleaning booth
is blown out via the exhaust wall and the exhaust fan over the roof.