Paint booth + cleaning booth FEIGE Fe 36 / 17000 + Fe 450 / 7000

other machines and plants / other machines and plants

Manufacturer: FEIGE

Model:Fe 36 / 17000 + Fe 450 / 7000

Type of machine: Paint booth + cleaning booth

item-No.: 167498247

Quantity: 1

Date: 11.07.2025

Year of manufacture: 2019

Location: Land-de Germany

Price:


Seller-item-No.:R2096

Paint booth
Manufacturer: Fig
Type: Fe 36 / 17000
Year of Make: 2019

Cleaning booth
Manufacturer: Fig
Type: Fe 450 / 7000
Year of Make: 2019

LACQUER:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 7,000 x 3,500 x 3,800 mm

Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
Three-phase current 400 V / 50 Hz

Exhaust fan (FU-controlled)
V = 17,000 m3/h, nominal power drive: 7.5 kW
Three-phase current 400 V / 50 Hz

Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 mbar

Pre-filter: G3 bags 200 mm
Ceiling filter: M5 EN 779
Exhaust air filter: folding carton filter and Paintstop
Current type motor: 3x 400 V / 50 Hz

LEL limit: < 10%
Paint shop: c = 0.15 g/m3 / LEL 0.38%
Drying operation: c = 1.52 g/m3 / LEL 3.80%

Basis of calculation: 3,000 kg / year with 41% LM content
Daily consumption: approx. 2.1 kg/h
Solvent quantity: 3,211 g/batch

CLEAN:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 6,000 x 3,500 x 3,800 mm

Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
of which 7,000 m3/h cleaning booth
Three-phase current 400 V / 50 Hz

Exhaust fan (FU-controlled)
V = 7,000 m3/h, nominal power drive: 3.0 kW
Three-phase current 400 V / 50 Hz

Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 M57388 mbar

Pre-filter: G3 bags 200 mm
Ceiling filter: M5 EN 779
Current type motor: 3x 400 V / 50 Hz

In the "Clean" area, the fresh air is supplied from the outside via the supply air fan
and cleaned of coarse dust. The supply fan pushes this air
via the sewer line into the exhaust box. Before the heated fresh air enters the
the cleaning booth is blown, a second filter is applied to the filter ceiling
Filter stage in which the air is freed from fine dust. Afterwards,
the air into the washroom practically dust-free. The exhaust air from the cleaning booth
is blown out via the exhaust wall and the exhaust fan over the roof.
Share this machine on Facebook:

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

Copy to you?

Save input data

Paint booth
Manufacturer: Fig
Type: Fe 36 / 17000
Year of Make: 2019

Cleaning booth
Manufacturer: Fig
Type: Fe 450 / 7000
Year of Make: 2019

LACQUER:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 7,000 x 3,500 x 3,800 mm

Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
Three-phase current 400 V / 50 Hz

Exhaust fan (FU-controlled)
V = 17,000 m3/h, nominal power drive: 7.5 kW
Three-phase current 400 V / 50 Hz

Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 mbar

Pre-filter: G3 bags 200 mm
Ceiling filter: M5 EN 779
Exhaust air filter: folding carton filter and Paintstop
Current type motor: 3x 400 V / 50 Hz

LEL limit: < 10%
Paint shop: c = 0.15 g/m3 / LEL 0.38%
Drying operation: c = 1.52 g/m3 / LEL 3.80%

Basis of calculation: 3,000 kg / year with 41% LM content
Daily consumption: approx. 2.1 kg/h
Solvent quantity: 3,211 g/batch

CLEAN:
Usable dimensions cabin LxWxH: 8,000 x 4,500 x 4,100 mm
Part size LxWxH max.: 6,000 x 3,500 x 3,800 mm

Supply fan (FU-controlled)
V = 24,000 m3/h, nominal power drive: 15.0 kW
of which 7,000 m3/h cleaning booth
Three-phase current 400 V / 50 Hz

Exhaust fan (FU-controlled)
V = 7,000 m3/h, nominal power drive: 3.0 kW
Three-phase current 400 V / 50 Hz

Air heating: - 10 to + 22 °C
Heating capacity burner max.: 160 kW
Heating medium: natural gas, 25 M57388 mbar

Pre-filter: G3 M57388 bags 200 mm
Ceiling filter: M5 EN 779
Current type motor: 3x 400 V / 50 Hz

In the "Clean" area, the fresh air is supplied from the outside via the supply air fan
and cleaned of coarse dust. The supply fan pushes this air
via the sewer line into the exhaust box. Before the heated fresh air enters the
the cleaning booth is blown, a second filter is applied to the filter ceiling
Filter stage in which the air is freed from fine dust. Afterwards,
the air into the washroom practically dust-free. The exhaust air from the cleaning booth
is blown out via the exhaust wall and the exhaust fan over the roof.
seller offer No. resale R2096
Share this machine on Facebook:
approved
dealer

Seller

logo dealer

METEC GmbH

Mr Joachim Peter
72622 Nürtingen
Germany

RESALE member since 2004

  • machine list (139)

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

(to all dealers for such a machine)

Copy to you?

(copy of your inquiry will be sent to your email address)

Save input data

(Save input data for further inquiries)