We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
127,346 used machines on RESALE, but how to find them? Machine Search
used
Control amplifier, servo motor control, power controller, thyristor power controller, thyristor regulator, power regulator -Manufacturer: KBR, power controller, power regulator, reactive power controller -Type: BK 2006 -Voltage: 230 V, 50 Hz -Dimensions: 150/145/H85 mm -Weight: 1.2 kg
used
Power supply, sliding contact STROMAG diameter: Ø 6 mm thread: Ø approx. 17.7 mm x 1.5 mm Length: 10 mm Dimensions: 75 x 22 x 22 mm
used
Key data: 504 KW, 630 kVA, 400 V
We offer for sale an MTU 12V2000 diesel emergency power generator: Specifications: Engine: MTU Type: 12V2000 Power: 504 kW Speed: 1500 rpm Voltage: 400 V Cos phi: 0.8 Frequency: 50 Hz Year of Make: 2005 Operating hours: 800 h Condition: Good Dimensions: BXHXL = 2450X3,000X12,000 mm Weight: 18,000 kg
used
2007 Mercedes Combined heat and power plant (CHP) The CHP plant was originally intended for an oil platform. Therefore, it is protected against salt water and can also be operated in island mode. Technical data (See pictures) CHP plant with Mercedes engine, which is designed for multi-quality fuel (diesel, heating oil, pyrolysis oil or vegetable oil). Thus preheating unit and corresponding exhaust gas purification. BJ. 2007. Operating hours: 0 (test run only); The unit was never connected to the network. If palm or vegetable oil is used, preheating” is required to get above the pour point. All pumps were completely overhauled by the manufacturer when we purchased them (see Rg with maintenance report). If you want to drive in island mode, this must be changed on the control + the controller on the generator must be replaced. In addition to electricity, the unit can also recover ...
used
used
used
Attention: Comes without battery! Auction-ID: A1-48726-3
used
Attention: Comes without battery! Auction-ID: A1-48726-5
used
Power test chamber with transformer transformer Input - primary 400 V three phases Output - Secondary Switchable - 230 V three phases - 400 V three phases - 525 V three phases - 660 V three phases Power 50 KVA Space requirement W - 800 x D - 400 x H - 2,000 mm Weight approx. 430 kg
used
Key data: 206 KW, 500 kVA, 400 V
Sokratherm Gas-CHP GG202 oE Gas electricity and heat generators from 2019 with 10,777 operating hours, Complete CHP (closed unit) with additional silencer. 1 available 202 KWel x 1,500 rpm, 400 V/50 Hz. AC Generator: Leroy Somer LSA 47.2M7 V 6/4, 500 KVA Manufacturer: Sokratherm Model: GG202 oE Type: Gas CHP Serial Number: 3131754 Engine: MAN E3262E302 Electric power [KWel]: 206 Thermal power [KWth]: 316 Gas Capacity [KWgas]: 561 Year of Make: 2019 Hours: 10,777 Weight unit [kg]: 6,500 Dimensions LxWxH [cm]: 400 x 150 x 240 AC Generator LSA 47.2M7 V 6/4 Manufacturer: Leroy Somer Model No.: LSA 47.2M7 V 6/4 Type: AC Synchronous Generator Serial Number: 353345/1 Power [KVA]: 500 Voltage [V]: 400 Frequency [Hz]: 50 Current [A]: 722 Speed [1/min]: 1,500 Year of manufacture: 2018
used
liter capacity: . l feed pressure: . bar coolant capacity: . l The technical data is manufacturer or operator information and is therefore not binding for us. We reserve the right to sell the goods prior to sale, our terms and conditions of business and sale apply exclusively. About us more than 400 of our own machines in stock over 12,000 m² of storage space, crane capacity 70 t more than 1,000 items of accessories for your workshop If you want to sell machines, production lines or your business, then contact us. You can find further offers on our website. Viewings are possible by arrangement. We look forward to your visit. Your Markus Hirsch team The data for this ad was created with ModulMWS - the software solution of LogoTech oHG.
used
used
used
used
Key data: 65 KW, 400 V
Buderus Gas Generator (CHP) E 0826 DN-60 Gas electricity and heat generator from 1998 with 41,972 operating hours, closed unit, generator with voltage fluctuations. 1 available 65 KWel x 1,500 rpm, 400 V/50 Hz. Manufacturer: Buderus Model No.: E 0826 DN-60 Type: Gas CHP Serial number: 03198-00020-283 Power [KWel]: 65 Power [KWth]: 110 Engine: MAN E0826 E301 Year of Make: 1998 Hours: 41,972 Weight unit [kg]: 2,100 Dimensions LxWxH [m]: 3.10 x 1.00 x 1.75
used
Attention: Comes without battery! Auction-ID: A1-48726-4
used
Attention: Comes without battery! Auction-ID: A1-48726-2
used
used
x-travel: 2.600 mm y-travel: 700 mm z-travel: 700 mm Control: SIEMENS SINUMERIC 840D table-size: 2.900x700 mm table weight: 2.150 Kg tool adaptor: SK 40 DIN 69872 workpiece length - max.: 300 mm workpiece weight: 6 kg workpiece dia.: 80/130 mm : 30 fach main drive: 18,4/14 kW speed: 14.000 mm/min rapid traverse: 40 m/min feed: 40 m/min Machine on: 18.859 h Spindle hours: 5.666 h internal coolant system feed: 40 Bar/600 l Chip coveyor: inkl. total power requirement: 55 kW weight of the machine ca.: 14.520 kg dimensions of the machine ca.: 10.280 x 7.230 x 3.042 mm The data for this ad was created with ModulMWS - the software solution of LogoTech oHG.
used
x-travel: 4.000 mm y-travel: 2.100 mm z-travel: 1.000 mm taper ISO: ISO 50 Number of revolutions: 5.000 rpm table-size: 4.020x2.010 mm table weight: 12.000 Kg Control: Heidenhein iTNC530 Tools place: 32 fach rapid taverse: 15.000 mm/min total power requirement: kW weight of the machine ca.: 39 t dimensions of the machine ca.: 10680x5600x5100 m The data for this ad was created with ModulMWS - the software solution of LogoTech oHG.
used
Power: 60 W, 2 independent channels Auction-ID: A7-48794-369
used
used
Key data: 200 KW, 225 kVA, 400 V
1 emergency generator with Deutz diesel engine and Siemens generator, Power 225 kVA = 200 kW, 400V/3PH/50Hz, Start with 20 bar compressed air, complete with 2 pressure vessels and matching compressor, approx. 1,000 operating hours, still completely operational
used
description: Here we offer a whole range with different Siemens SITOP power supplies. It is possible to buy the entire range, but also parts of this range can be purchased. After delivery / pickup, you have the right to return the purchase without giving reasons, within 2 weeks unfree and get back the purchase price afterwards. Furthermore we offe used inverters of the VLT 5000, 2800 and FCD series in different designs and performance levels. Also with or without BUS card. Before delivery, the inverters are professionally formatted to allow an uncomplicated re-start. DRINK has more than 4,000 mainly used but also original packaged components in stock. Including Siemens S5 / S7 PLC. Contact us, if you can not find the right component. All statements wihtout guarantee. Besides buying and selling of conveyors and machines our strength lies particularly in services an ...
used
Power: 60 W, 2 independent channels Auction-ID: A7-48794-380
used
Recording: 1/1 4. Auction-ID: A1-47436-102
used
Welded on mobile chassis Auction-ID: A1-47355-124
used
- Without gas bottle. Auction-ID: A1-46485-52
used
Key data: 3600 KW, 4600 kVA, 6600 V
We offer a MWM CHP Type: TBG 632 V16 for sale Specifications: Engine: MWM Type: TBG 632 V16 Power: 3600 kW Generator: AVK Power: 4600 KVA Voltage: 6600 V Running hours: 47,000 h Weight: 46,000 kg Scope of delivery: motor plus generator on base frame
used
- Without gas bottle. Auction-ID: A1-46485-54
used
Being Bosch GSB16RE drill with case and Makita 9565CR angle grinder. Auction-ID: A1-46485-160
used
A small Finsterle hydraulic unit with an AC-Motoren GmbH motor is available. Motor output: 7.5kW, pump flow rate: 37.5l/min, max. rated operating pressure: 100bar, tank volume: approx. 350l. An on-site inspection is possible.
used
Power cable, flat cable, crane cable, rubber hose cable -Power cable: Flat cable, crane cable, 4-core -Type: 4G 2.5 -Length: 30 m -Transport dimensions: roll Ø 565 x 25 mm -Weight: 8.4 kg
used
Safety relay, safety control, overrun relay, flow monitor, contactor, relay, current monitor -Manufacturer: Telemecanique, Power Monitor Ovp -Type: RM4JA31M -Cardboard dimensions: 90/80/H25 mm -Weight: 0.1 kg
used
used
used
Outputs: 1x 400V and 1x 230V Auction-ID: A1-48851-1160
used
used
used
used
used
used
used
New and original packaging. Auction-ID: A1-48851-436
used
used
used
Capacity: 3,224 kW Volts: 400 HZ: 50 Condition: Very Good Scope of Supply: Complete Turbine Power Station with turbine and alternator, Control Panel, Condensor, Cooling Towers, Spilling Unit, Switchgear, Synchronisation panel, Transformer, Piping / wiring / pumps. Total cost for power plant components was around 3 million on the actual power plant components. Nominal Steam requirement to run the turbine is 17, 5 t/h at 29 barg & 350 °C. Available for sale from Gas Engine Exchange. Please check our full range of equipment at gasengineexchange.com.
used
Oil-Insulated Power Transformers for Sale Manufacturer: Brown Boveri Model: TRFKa 1350/30 Power Rating: 1350 kVA High Voltage: - 26.25 kV (Middle position) - 27.56 kV (Position 1) - 24.93 kV (Position 5) Low Voltage: 6.3 kV Current Rating: - High Voltage: 29.7 A (Middle position) - Low Voltage: 124 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1972 Status: In operation until March 2025 Notable Condition: High CO levels and water content; oil drying and treatment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Transformer 1 - Manufacturer: ELIN - Model: TDQ-164A11S9K-99 - Power Rating: 15 MVA - High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) - Low Voltage: 6.3 kV - Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A - Frequency: 50 Hz - Cooling: ONAN - Year of Manufacture: 1994 - Status: Out of service since 2022 - Notable Condition: Relatively high CO levels (due to oxidation); insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
used
Oil-Insulated Power Transformers for Sale Manufacturer: ELIN Model: TDY-164A11S9K-99 Power Rating: 15 MVA High Voltage: - 121.5 kV (Position 0) - 118.463 kV (Position -1) - 115.425 kV (Position -2) Low Voltage: 6.3 kV Current Rating: - High Voltage: 71.3 A (Position 0), 73.1 A (Position -1), 75.05 A (Position -2) - Low Voltage: 1375 A Frequency: 50 Hz Cooling: ONAN Year of Manufacture: 1993 Status: In operation until 2025 Notable Condition: High CO levels, insufficient oil inhibitor content. Oil treatment with inhibitor replenishment recommended. Find more here - / Contact us at -
maximum number of results exceeded