Cat. No. 07-109-3 in very good condition Standard: Manufacturer NEUMO Type DUPLEX 80/100 Operating/temperature 90C Maximum operating pressure 10 bar Adjustable V2A - Frame Heat conduction inside NW 50 Heat conduction outside NW 100 Product management NW 80 with 7 tubes x 6 m long without measuring technology and connections Dimensions and weight: Length: 620 cm Height: 140 cm Depth/width: 70 cm Weight: 755 kg For inquiries: Tel: 09353 90905-0 Fax: 09353 90 90 5-22 or 0171 651 8248 We also have other winery machines - request our complete catalogue! All prices ex works plus law VAT Intermediate sale reserved! Delivery time: immediately from stock The price quoted is only valid for 1 piece
used
Material: Stainless steel Built: 1993 Content: 1770 ltr Pressure inside: 0.5bar Pressure outside: 10bar Weight: 5000 kg L x W x H: 4700mm/900mm/1200mm An indirect heat exchanger with mechanical material transport. Very good condition. YOU ARE A NEW, OUTDATED AND USED
used
Water cooler, ruck cooler GEA, 400-600KW.with radial fan, suitable for air duct as heating or to blow into the open.
used
used
Air heater Manufacturer: GEA Happel Klimatechnik GmbH Type: MAXX M311D. BA3. X ATYPE Year of construction: 2004 Technical data: Rated voltage: 3 x 400 / 50 V/Hz Nominal power: 0.30/0.17/0.12 A Protection class: IP54
used
Reznor UDSA Gas Air Heater Gas WLE Type: UDSA050-4E Gas Appliances Type: BSP-C12-C32-C52-C62 Purpose: DE Gas Category: I2ELL Gas Type: G20 Natural Gas Connection pressure: 20 mbar Nozzle pressure: 7.90 mbar Max. nominal heat load (Hs) QN: 58.60 kW Max. Nominal Heat Load (Hi) QN: 52.80 kW Min. Nominal Heat Load (Hs) QN: Min. Nominal Heat Load (Hi) QN: Max. nominal heat output: 48.58 kW Min. nominal heat output: Connection voltage: 230V 1N ,50Hz Air flow rate: 5180 m3/h Degree of protection: IP20 Pin No. 0461BN0677 UDSA Gas Air Heaters – Efficient Right to the Peaks The best-known device from REZNOR is the UDSA gas hot air generator, which ensures even air distribution in industrial halls. The easy-to-install recirculation unit is available in 14 output sizes from 7 to 97 kW and consists of a heat exchanger, gas burner and an exhaust fan. The combustion air can ...
used
Reznor UDSA Gas Air Heater UDSA Gas Air Heaters – Efficient Right to the Peaks The best-known device from REZNOR is the UDSA gas hot air generator, which ensures even air distribution in industrial halls. The easy-to-install recirculation unit is available in 14 output sizes from 7 to 97 kW and consists of a heat exchanger, gas burner and an exhaust fan. The combustion air can be taken either from the outdoors or from the showroom as standard. The UDSA hot air generator from REZNOR ensures even air distribution in the heated hall. Its patented heat exchanger sets new standards in terms of flow behavior and heat transfer and ensures an efficiency of over 92 percent. UDSA: compact, revolutionary and trend-setting. With this generation of devices, halls can be heated in a particularly economical way directly – i.e. without central heating – with decentrally arranged, modula ...
used
Kroll M 150 Mobile Warm Air Generator Application Heating of halls, tents and construction sites Frost-free keeping in horticultural businesses or warehouses of all kinds Fast drying of new buildings Additional heating in the cold season Fuel: Heating oil EL Nominal heat output: 135 kW Nominal heat load: 150 kW Oil throughput: 12.7 kg/h Air volume flow: 7,300 m³/h Electrical connection: 220 V / 6.1 A Power consumption: 1.38 kW Degree of protection>: IP 44 Metrics: Length: 2600 mm Width: 900 mm Height: 1300 mm Weight: 270 kg More items - new and used - can be found in our shop! International shipping costs on request!
used
Reznor UDSA Gas Air Heater UDSA Gas Air Heaters – Efficient Right to the Peaks The best-known device from REZNOR is the UDSA gas hot air generator, which ensures even air distribution in industrial halls. The easy-to-install recirculation unit is available in 14 output sizes from 7 to 97 kW and consists of a heat exchanger, gas burner and an exhaust fan. The combustion air can be taken either from the outdoors or from the showroom as standard. The UDSA hot air generator from REZNOR ensures even air distribution in the heated hall. Its patented heat exchanger sets new standards in terms of flow behavior and heat transfer and ensures an efficiency of over 92 percent. UDSA: compact, revolutionary and trend-setting. With this generation of devices, halls can be heated in a particularly economical way directly – i.e. without central heating – with decentrally arranged, modu ...
used
Reznor UDSA Gas Air Heater UDSA Gas Air Heaters – Efficient Right to the Peaks The best-known device from REZNOR is the UDSA gas hot air generator, which ensures even air distribution in industrial halls. The easy-to-install recirculation unit is available in 14 output sizes from 7 to 97 kW and consists of a heat exchanger, gas burner and an exhaust fan. The combustion air can be taken either from the outdoors or from the showroom as standard. The UDSA hot air generator from REZNOR ensures even air distribution in the heated hall. Its patented heat exchanger sets new standards in terms of flow behavior and heat transfer and ensures an efficiency of over 92 percent. UDSA: compact, revolutionary and trend-setting. With this generation of devices, halls can be heated in a particularly economical way directly – i.e. without central heating – with decentrally arranged, modu ...
used
used
Viessmann Vitoplex 200 oil/gas boiler 900 kW with Weishaupt gas burner Manufacturer: Viessmann Model: Vitoplex 200 Type: Oil/Gas Boiler Nominal heat output for oil and gas: 900 kW Rated rated heat output: 978 kW Boiler capacity: 1325 l Permissible operating pressure: 6 bar Permissible operating temperature: 110 °C Standards: EN 14394 / TRD 702 / TS EN 303-1 / TS EN 303-3 Location: Paderborn Burners: Manufacturer: Max Weishaupt GmbH Burner type: WM-G10/4-A monarch Design: ZM Serial Number: 40457248 Year of manufacture: 2018 Country of destination: DE Category: II2R3R Gas Type: N Power range: min. 110 kW / max. 1250 kW Connected pressure: min. 100 mbar / max. 2500 mbar NOx class: 2 Control voltage: 230V 1~50Hz Mains voltage: 400 V 3~ N PE 50 Hz Electrical power: 2.16 kW Degree of protection: IP54
new
Wilms indoor heater new ovp Manufacturer Wilms Type B125 Diesel Oil-powered heaters with open flame, e.g. for deicing or thawing materials, vehicles, pipelines, etc. As additional heating of stables as well as of operating and storage rooms with sufficient ventilation. Electric connection: 230 V, 50 Hz. Room thermostat installed as standard. Type: B 125 Heating capacity: 40 kW - 34,400 kcal/h Air power:: 920 m3/h Consumption: 3 kg/h Tank: 38 l Weight: 24 kg
used
used
Thermal systems, fan heaters, heating elements -Space-saving fan heater: HVL 150 -Power: 150 W -Price: per piece -Number: 4 pieces -Dimensions: 110/105/H60 mm -Weight: 0.5 kg/piece
used
Thermal system, fan heater -Space-saving fan heater: HVL 031 -Power: 225 W -Price: per piece -Number: 2 pieces -Dimensions: 90/130/H160 mm -Weight: 0.9 kg/piece
used
Heating fan, mobile heater, gas heater, gas blower -Power output: adjustable from 50 to 100 kW -Length: 560 -Width: 350 mm -Height: 500 mm -Gas type: Propane -Quantity: 1 available Price: per piece -Weight: 16 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power output: adjustable 50 kW -Connection pressure: 0.35-1.5 bar -Air flow rate: 1000 m³/h -Weight: 20 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power: adjustable 30 kW -Consumption: 2.3 kg/h -Connection pressure: 0.35-1.5 bar -Air flow rate: 1000 m³/h -Weight: 21 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power output: adjustable: 24.3 to 64 kW -Consumption: 1.5 to 5 kg/h -Connection pressure: 0.6-3.0 bar -Air flow rate: 2150 m³/h -Weight: 26 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power output: adjustable: 24.3 to 64 kW -Consumption: 1.5 to 5 kg/h -Connection pressure: 0.6-3.0 bar -Air flow rate: 2150 m³/h -Weight: 30 kg
used
Thermal system, fan heater, heating elements -Manufacturer: Ziehl-Abegg, axial fan, axial fan, heating fan -Axial fan: type DADL 350/6 -Power: kW -Dimensions: Ø 470 x 245 mm -Weight: 9.1 kg
T9STELA AIR HEATER indirect 2000 KW, SLI 2000; Weishauptbrenner L9T OIL Tel. 01715213204
used
immersion heater -Power: max. 2000 W -Step switch: 12 positions -Body: made of aluminum -Connection: 230 V -Weight: 5 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power: adjustable 50 kW -Consumption: 2-4 kg/h -Connection pressure: 0.35-3.0 bar -Air flow rate: 1570 m³/h -Weight: 32 kg
used
Heating fan, mobile heater, gas heater, gas blower -Power output: approx. 30 kW -Dimensions: 620/340/H540 mm -Weight: 20 kg
used
used
used
used
used
used
Parking heater for sale Bosch Part Number: 0 141 002 021
used
Perkin Elmer Heater with Quartz Cuvette for Perkin Elmer AAS Systems
used
used
Cartridge heater, sectional radiator for liquid heating JEKA 2051259 1760 W 230 V New ! Dimensions: 380 x 52 x 52 mm
used
Cartridge heater, immersion radiator LOVAL 6000 W ( 6000W ) 400 V immersion depth: 420 mm flange diameter: Ø 48 / 64 mm with protective tube for temperature sensor New ! Dimensions: 550 x 65 x 65 mm
used
Heating element, air heater - without housing VOLTA ERR 7,000 W 12 Heating rods 380 V Dimensions: 560 x 250 x 145 mm
used
Axial Dry Cooler, Güntner GFH090.2A/2x3-M(S) Manufacturer: Güntner. Medium: Water Glycol 70/30% Medium temperature: Inlet 90º C. Outlet 70º C. Cooling Capacity: 800kW Air temperature: 35º C. Fans: 6 pieces, 1.5kW, 400V, 50Hz, 3 conductors Connection: Inlet 1x DN80, Outlet 1x DN80 Dimensions: LxWxH = 6,200x22921x1460mm Weight: 1358kg Sound pressure level: 53 dB(A) 10m distance, Year of Make: 2016 Condition: Good, leakage and fans tested Jenbacher, Dry cooler, Dry air cooler, Emergency cooler, drycooler, Glycol cooling water
used
Axial Dry Cooler, Güntner GFH090.2A/2x3-M(S) Manufacturer: Güntner. Medium: Water Glycol 70/30% Medium temperature: Inlet 90º C. Outlet 70º C. Cooling Capacity: 800kW Air temperature: 35º C. Fans: 6 pieces, 1.5kW, 400V, 50Hz, 3 conductors Connection: Inlet 1x DN80, Outlet 1x DN80 Dimensions: LxWxH = 6,200x22921x1460mm Weight: 1358kg Sound pressure level: 53 dB(A) 10m distance, Year of Make: 2016 Condition: Good, leakage and fans tested Jenbacher, Dry cooler, Dry air cooler, Emergency cooler, drycooler, Glycol cooling water
used
Tube heaters Manufacturer: Ahrens & Bode Pressure-resistant up to 25 bar
used
Pressure heater with oil tank from Viessmann. The heater is permanently installed in a sea container and has only been in operation for 16 hours! Find more here - / Contact us at -
used
Hardly used, in very good condition. There is no longer any need for sale.
used
here are 3 new heaters with cable and accessories. Brand-new Special price
used
A total of 71 Kroll air heaters are available, 30x LH 130 V10, 1x LH 130 V20, 7x LH 230 V10, 3x LH 330 V10, 1x LH 420 V10, 6x LH 430 V10, 1x LH 430 V20, 11x LH 530 V10 and 11x LH 630 V10. The fans are used and partly have bent fins and scratches. An on-site inspection is possible.
used
Loos International Weishaupt Brenner 1700 L Volume 1500-1630 KW 6 Bar 110 Degree Temp. Year of construction 2003
used
Universal temperature control unit WEINREICH type WTD 4Temperature control unit with electric heating and connections for external coolingFabr. No.: 11932217 year of construction 1993Temperature max. 140CBorcing pressure max. 6 barPump capacity 30 l/min. Tank volume 4 litresHeating capacity 4 kWeergisation capacity heat exchanger 15 kWCotor capacity of the pump 0.37 kWUmrune water supply + return G 3/8Cooling water flow + return G 3/8Total capacity 4.4 kWNe-connection 380 volts, 50 Hz, CEE plug-in temperature control medium water
used
F24 BOILER : ORGANIC HEAT TRANSFER MATERIAL HEATER PRODUCTION YEAR : 2015 ORIGIN : CHINA RATE CALORIFIC POWER : 3500KW MAWP : 1.0MPa