Power Plant LAMBION Power Plant

energy & engines: power generators, engines, turbines, boilers / power generators

Manufacturer: LAMBION

Model:Power Plant

Type of machine: Power Plant

item-No.: 166200957

Quantity: 1

Date: 02.04.2026

Location: Berlin, Germany

Price:


Seller-item-No.:5142410

Power plant (Lambion-Howden-Scheuch-Hamworthy)

History

-

Commissioning: 2009

-

Power plant built for the heat supply

Manufacturer:

Lambion

Siemens (turbine, measurement and control technology)

Imtech

(electrics and performance data:

950 kW rated electrical power

2.00 MW rated thermal output HT(128

128°C)

1.50 MW thermal output NT (85

85°C)

6.74 MW thermal firing capacity

Steam output: 7.5 t/h

approx. 11,000 tonnes of fuel required per year LPM and

WHS

Boiler

Manufacturer Lambion

Year of construction 2008

Maximum steam production [t/h] 7.5

Max. permissible pressure [bar] 32

Max. permissible vapour temperature [

[°C] 440

Turbine / Generator

manufacturer

Howden

Machine TWIN CA 34

Year of construction: 2008

Generator manufacturer:

AvK

Generator

Generator type: DSG 74 M2

System data:

Flue gas cleaning

Manufacturer Scheuch

Condenser / recooling

manufacturer

Hamworthy

Condensing capacity 4.5 MW

Recooling plant

30 Thermokey emergency cooler, FU controlled

Other system components

Transformer 20kV/0.4kV, 1,600 kVA

-

Siemens control system

Water treatment Veolia

Flue gas measurement

Airtec

Moving floor system

Wet ash removal

Find more here - /
Share this machine on Facebook:

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

Copy to you?

Save input data

Power plant (Lambion-Howden-Scheuch-Hamworthy)

History

-

Commissioning: 2009

-

Power plant built for the heat supply

Manufacturer:

Lambion

Siemens (turbine, measurement and control technology)

Imtech

(electrics and performance data:

950 kW rated electrical power

2.00 MW rated thermal output HT(128

128°C)

1.50 MW thermal output NT (85

85°C)

6.74 MW thermal firing capacity

Steam output: 7.5 t/h

approx. 11,000 tonnes of fuel required per year LPM and

WHS

Boiler

Manufacturer Lambion

Year of construction 2008

Maximum steam production [t/h] 7.5

Max. permissible pressure [bar] 32

Max. permissible vapour temperature [

[°C] 440

Turbine / Generator

manufacturer

Howden

Machine TWIN CA 34

Year of construction: 2008

Generator manufacturer:

AvK

Generator

Generator type: DSG 74 M2

System data:

Flue gas cleaning

Manufacturer Scheuch

Condenser / recooling

manufacturer

Hamworthy

Condensing capacity 4.5 MW

Recooling plant

30 Thermokey emergency cooler, FU controlled

Other system components

Transformer 20kV/0.4kV, 1,600 kVA

-

Siemens control system

Water treatment Veolia

Flue gas measurement

Airtec

Moving floor system

Wet ash removal

Find more here - /
seller offer No. resale 5142410
Share this machine on Facebook:

Seller


verified user

RESALE member since 2024

For more information about the seller, please send him an enquiry and select the option "Copy to you?".

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

(to all dealers for such a machine)

Copy to you?

(copy of your inquiry will be sent to your email address)

Save input data

(Save input data for further inquiries)