Power plant (Lambion-Howden-Scheuch-Hamworthy)

History

-

Commissioning: 2009

-

Power plant built for the heat supply

Manufacturer:

Lambion

Siemens (turbine, measurement and control technology)

Imtech

(electrics and performance data:

950 kW rated electrical power

2.00 MW rated thermal output HT(128

128°C)

1.50 MW thermal output NT (85

85°C)

6.74 MW thermal firing capacity

Steam output: 7.5 t/h

approx. 11,000 tonnes of fuel required per year LPM and

WHS

Boiler

Manufacturer Lambion

Year of construction 2008

Maximum steam production [t/h] 7.5

Max. permissible pressure [bar] 32

Max. permissible vapour temperature [

[°C] 440

Turbine / Generator

manufacturer

Howden

Machine TWIN CA 34

Year of construction: 2008

Generator manufacturer:

AvK

Generator

Generator type: DSG 74 M2

System data:

Flue gas U51258834 cleaning

Manufacturer Scheuch

Condenser / recooling

manufacturer

Hamworthy

Condensing capacity 4.5 MW

Recooling plant

30 Thermokey emergency cooler, FU controlled

Other system components

Transformer 20kV/0.4kV, 1,600 kVA

-

Siemens control system

Water treatment Veolia

Flue gas measurement

Airtec

Moving floor system

Wet ash removal

Find more here - /
Partager cette machine sur Facebook:

Enquête

Marchand de machines?

S'il vous plaît remettre éventuellement

Envoyer la demande?

Copie pour vous?

Save input data

Power plant (Lambion-Howden-Scheuch-Hamworthy)

History

-

Commissioning: 2009

-

Power plant built for the heat supply

Manufacturer:

Lambion

Siemens (turbine, measurement and control technology)

Imtech

(electrics and performance data:

950 kW rated electrical power

2.00 MW rated thermal output HT(128

128°C)

1.50 MW thermal output NT (85

85°C)

6.74 MW thermal firing capacity

Steam output: 7.5 t/h

approx. 11,000 tonnes of fuel required per year LPM and

WHS

Boiler

Manufacturer Lambion

Year of construction 2008

Maximum steam production [t/h] 7.5

Max. permissible pressure [bar] 32

Max. permissible vapour temperature [

[°C] 440

Turbine / Generator

manufacturer

Howden

Machine TWIN CA 34

Year of construction: 2008

Generator manufacturer:

AvK

Generator

Generator type: DSG 74 M2

System data:

Flue gas U51258834 cleaning

Manufacturer U51258834 Scheuch

Condenser / recooling

manufacturer

Hamworthy

Condensing capacity 4.5 MW

Recooling plant

30 Thermokey emergency cooler, FU controlled

Other system components

Transformer 20kV/0.4kV, 1,600 kVA

-

Siemens control system

Water treatment Veolia

Flue gas measurement

Airtec

Moving floor system

Wet ash removal

Find more here - /
seller offer No. resale 5142410
Partager cette machine sur Facebook:

Vendeur

logo dealer

UCY Industrial GmbH

Monsieur Nick Breinfalk
82049 Pullach
Germany

RESALE membre depuis que 2024

  • liste des machines (1394)

Enquête

Marchand de machines?

S'il vous plaît remettre éventuellement

Envoyer la demande?

(à tous les concessionnaires pour une telle machine)

Copie pour vous?

(copie de votre demande vous sera envoyée à votre adresse e-mail)

Save input data

(Save input data for further inquiries)