We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
137,084 used machines on RESALE, but how to find them? Machine Search
Please try with a different search term.
used
Three-phase motor, electric motor -Power: 0.18 kW -Speed: 1380 rpm -Shaft: Ø 11 x 22 mm -Construction: B5 -Protection class: IP 54 -Dimensions: 175/170/H140 mm -Weight: 5.6 kg
used
used
Key data: 90 KW, 1485 1/min
TECHNICAL SPECIFICATIONS Manufacturer: ELEKTRA Elektromotoren Dillingen Description: Electric drive motor Type: IEC squirrel cage motor (EN 60034) Power: 90 kW Speed: 1485 1/min Frequency: 50 Hz Standard voltage: 400 V Design: IM B3 Degree of protection: IP 55 Weight: 580 kg SPECIFIC COMMENT - Incl. 1 flywheel extra
used
Electric motor, three-phase motor -Manufacturer: Siemens -Type: 1LA5166-1BJ40-Z IEC160L -Power: 2.1/3.1/9 kW -Speeds: 730/980/1460 rpm -Shaft: Ø 42 mm -Construction: B3B5 -Protection class: IP 54 -Number: 2x motors available -Price: per piece -Dimensions: 640/355/H360 mm -Weight: 97 kg
used
Geared motor, electric motor, three-phase motor, electric geared motor -Manufacturer: Varvel, geared motor -Type: FRS40/PC 19MM i=10 IEC63B14 -Speed: 135 rpm -Motor: Verhagen type 4P.T063B 0.18 kW 1350 rpm -Protection rating: IP55 -Hollow shaft: Ø 19 x 80 mm -Design: B14 -Dimensions: 385/122/H165 mm -Weight: 6.2 kg
used
Safety switch, safety switch, protective grille switch, limit switch, button, safety switch, position switch, magnetic locking switch, safety locking switch -Manufacturer: Schmersal, safety locking device made from CNC milling machine Mikron UME 600 -Type: AZM 161SK-33rka-024 IEC 60947-5-1 -Technical data: see photo of nameplate -Transport dimensions: 270/260/H60 mm -Weight: 1.5 kg
used
Geared motor, electric motor, electric geared motor, bevel geared motor -Speed: 5.3 rpm -Power: 3.0 kW -Design: B3 -Protection class: IP55 -Shaft: Ø 65 x 130 mm -Gearbox: Nord Getriebebau Type SK.63 IEC 100 -Electric motor: DIETZ type FDR100LB/4 -Dimensions: 890/330/H490 mm -Weight: 166 kg
used
Overview The crater was used in a Belgian brewery and was stopped in Summer 2024. It was used to put 330ml bottles with mechanical closure into a wooden or plastic crate. Technical Details Manufacturer: TMG Year of manufacture: 2018 Model: IEC 61439-2 Bottle Format: 330ml Crate format: 4x3 wooden or plastic crate Capacity: 8 cycles per minute
used
Gearboxes, stin gearboxes, angular gearboxes, transmission gearboxes, crane gearboxes -Ratio: 16.29: 1 -Hollow shaft: Ø 80 x 310 mm -Hole circle: Ø 300/ M16 -Price: per piece -Number: 2 pieces -Dimensions: 700/540/H405 mm -Weight: 282 kg/piece
used
Electric motor, three-phase motor -Power: 11 kW -Speed: 2910 rpm -Shaft: Ø 42 mm -Construction: B35 -Protection class: IP 54 -Number: 3x available -Price: per piece -Dimensions: 590/354/H405 mm -Weight: 76 kg
used
Brake motor, electric motor, three-phase motor -Power: 2.2 kW -Speed: 945 rpm -Shaft: Ø 28 mm -Construction: B3 -Protection class: IP 44 -Brake: 380 V -Number: 1x available -Price: per piece -Dimensions: 500/270/H240 mm -Weight: 53 kg
used
Electric motor, three-phase motor with 2 speeds -Power: 2.1/7 kW -Speed: 930/1450 rpm -Shaft: Ø 38 mm -Construction: B3 -pole changing -Protection class: IP 54 -Number: 1x available -Price: per piece -Dimensions: 450/260/H330 mm -Weight: 48 kg
used
Electric motor, three-phase motor -Power: 2.1/7 kW -Speed: 975/1450 rpm -Shaft: Ø 38 mm -Construction: B5 -Protection class: IP 54 -Number: 2x available -Price: per piece -Dimensions: 495/297/H340 mm -Weight: 53 kg
used
geared motor, electric motor -Speed: 76 rpm -Power: 0.37 kW -Design: B5 -Hollow shaft diameter: Ø 25 mm -Protection class: IP 54 -Weight: 14 kg
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE2200H OUTPUT (AC) Rated AC power: 2 200 VA Maximum AC power: 2 200 VA Rated AC voltage: 220 / 230 V AC voltage range: 184 – 264.5 V Nominal AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current: 10 A Network monitoring and anti-islanding protection with configurable thresholds per country: yes INPUT (DC) Maximum DC Power: 3 400W Transformerless inverter: Yes Maximum input voltage: 480 V Rated input voltage: 380 V Maximum Input Current: 6.5A Reverse polarity protection: Yes Earth leakage detection: 600 kΩ sensitivity Maximum inverter efficiency: 99.2 % European weighted efficiency: 98.3 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Communication interfaces: RS485, Ethernet, optional ZigBee, optional Wi-Fi, optional cellular network Smart Energy Management: feed-in limitation, home energy management, SolarEdge applications S ...
used
Model: SolarEdge SE10K OUTPUT (AC) Rated AC power: 10 000 VA Maximum AC power: 10 000 VA Rated AC voltage (phase-to-phase / phase-neutral): 380 / 220 V – 400 / 230 V AC voltage range (phase-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum AC Output Current (per phase): 16 A Supported network: three-phase, 3/N/PE (star connection with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 13 500W Transformerless, ungrounded inverters: yes Maximum input voltage: 900 V Nominal input DC voltage: 750 V Maximum Input Current: 16.5A Reverse polarity protection: Yes Ground insulation detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.6 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Commu ...
used
Model: SolarEdge SE12.5K OUTPUT (AC) Rated AC power: 12 500 VA Maximum AC power: 12 500 VA Rated AC voltage (line-to-line / line-neutral): 380 / 220 V – 400 / 230 V AC voltage range (line-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current (per phase): 20 A Supported network: three-phase, 3/N/PE (with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 16 650 W Transformerless inverter, not grounded: yes Maximum input voltage: 900 Vdc Nominal input DC voltage: 750 Vdc Maximum input current: 21 A Reverse polarity protection: Yes Ground fault detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.7 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Communication Inter ...
used
Model: SolarEdge SE10K OUTPUT (AC) Rated AC power: 10 000 VA Maximum AC power: 10 000 VA Rated AC voltage (phase-to-phase / phase-neutral): 380 / 220 V – 400 / 230 V AC voltage range (phase-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum AC Output Current (per phase): 16 A Supported network: three-phase, 3/N/PE (star connection with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 13 500W Transformerless, ungrounded inverters: yes Maximum input voltage: 900 V Nominal input DC voltage: 750 V Maximum Input Current: 16.5A Reverse polarity protection: Yes Ground insulation detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.6 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Commu ...
used
Model: SolarEdge SE10K OUTPUT (AC) Rated AC power: 10 000 VA Maximum AC power: 10 000 VA Rated AC voltage (phase-to-phase / phase-neutral): 380 / 220 V – 400 / 230 V AC voltage range (phase-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum AC Output Current (per phase): 16 A Supported network: three-phase, 3/N/PE (star connection with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 13 500W Transformerless, ungrounded inverters: yes Maximum input voltage: 900 V Nominal input DC voltage: 750 V Maximum Input Current: 16.5A Reverse polarity protection: Yes Ground insulation detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.6 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Commu ...
used
Model: SolarEdge SE10K OUTPUT (AC) Rated AC power: 10 000 VA Maximum AC power: 10 000 VA Rated AC voltage (phase-to-phase / phase-neutral): 380 / 220 V – 400 / 230 V AC voltage range (phase-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum AC Output Current (per phase): 16 A Supported network: three-phase, 3/N/PE (star connection with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 13 500W Transformerless, ungrounded inverters: yes Maximum input voltage: 900 V Nominal input DC voltage: 750 V Maximum Input Current: 16.5A Reverse polarity protection: Yes Ground insulation detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.6 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Commu ...
used
Model: SolarEdge SE12.5K OUTPUT (AC) Rated AC power: 12 500 VA Maximum AC power: 12 500 VA Rated AC voltage (line-to-line / line-neutral): 380 / 220 V – 400 / 230 V AC voltage range (line-neutral): 184 – 264.5 V AC frequency: 50 / 60 Hz ±5 % Maximum continuous AC current (per phase): 20 A Supported network: three-phase, 3/N/PE (with neutral) Emission monitoring, anti-islanding protection, power factor and configurable thresholds per country: yes INPUT (DC) Maximum DC Power (STC Module): 16 650 W Transformerless inverter, not grounded: yes Maximum input voltage: 900 Vdc Nominal input DC voltage: 750 Vdc Maximum input current: 21 A Reverse polarity protection: Yes Ground fault detection: 700 kΩ sensitivity Maximum inverter efficiency: 98 % European weighted efficiency: 97.7 % Night Power Consumption: < 2.5W ADDITIONAL FUNCTIONS Supported Communication Inter ...
used
Vötsch VT 7030 S2 Thermal Shock Test Chamber -80 °C to +220 °C The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a familiar environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a wide range of environmental conditions for scientific studies, product testing, and process controls. Data for temperature tests in single-chamber operation Hot Chamber: Thermal shock test chamber Test chamber 300 l Temperature range +50 °C to +220 °C Temperature deviation in time in the middle of the usable space ± 1 K Temperature deviation spatially ± 2 K Temperature gradient (according to IEC 60068-3-5) 4 K Temperature change rate (according to IEC 60068-3-5, measured in supply air) Heating 11 K/min Cold chamber: Thermal shock te ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1/L2/L3/N/PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimensions (H× W ...
used
Model: DOTR 63000/123 Rated Power: 50 / 63 MVA High Voltage (HV): 115 kV High Voltage Tapping Range: +9 / -9 x 1.778% (adjustable under load) Insulation Level HV: 123/550/230 kV Low Voltage (LV): 31.5 kV Insulation Level LV: 36/170/70 kV Tertiary Voltage: 6 kV Insulation Level TW: 12/75/28 kV Frequency: 50 Hz Vector Group: Yynyn0(d) Cooling Method: ONAN / ONAF Maximum Oil Temperature Rise: 60 K Maximum Winding Temperature Rise: 65 K Ambient Temperature Range: -25°C to 40°C Impedance: - At 50 MVA: 15.8% (± IEC-Tolerance) - At 63 MVA: 21% (±7.5%) No-Load Losses: 12.5 kW (+IEC-Tolerance) Load Losses at 50 MVA: 154 kW (+IEC-Tolerance) Noise Power Level at ONAF (No Load): 80 dB(A) Weight Details: - Shipping Weight: Approx. 87,500 kg - Weight of Oil: Approx. 15,300 kg - Active Part: Approx. 58,500 kg - Total Weight: Approx. 89,800 kg Dimensions: - Shipping Dimensions ...
used
A Rehm Invertig Pro 350 AC DC and a Rehm Invertig Pro 450 DC are available, used and in good condition. 1) Invertig Pro 350 AC DC, standards: IEC 60 974-1 IEC 60 974-2, welding current range TIG: 3-350A, output voltage U₂ at maximum current: approx. 24V, open circuit voltage U₀: approx. 91V, duty cycle 100 percent for TIG at 350A, mains voltage input: three phase 400V 50Hz, protection class: IP23S, protection category: S, setting range: 3-350A for TIG in this AC DC version, duty cycle 100 percent at 40°C 350A for TIG 100 percent duty cycle, input fuse protection: 32A at 3x400V for the 350 AC DC version, length: 520mm, width: 360mm, height: 460mm, weight: 29.5kg for AC DC version. 2) Invertig Pro 450 DC, standard: IEC 60 974-1, welding current range TIG: 3-450A, output voltage U₂ at maximum current: approx. 28V, open circuit voltage U₀: approx. 91V, duty cycle 100 percent at 450A ...
new
The Keyence SL-V60H security light curtain is a modern solution for securing the lower zone in various industrial applications. Equipped with detection functions, it provides reliable protection and enhances the safety of operations. The product is characterized by a solid construction and precise workmanship, which makes it ideal for demanding conditions. Model: SL-V60H Detection Capacity: ø25mm Distance between beam axes/lens diameter: 20 mm/ø5 mm Effective Beam Angle: Max. ±2.5° (when the operating range is 3 m or more) Working Distance: 0.1 to 9 m Response time (ms): ON→OFF 14,21 OFF →ON. 54,21 Light Source: Infrared LED (850nm) Operating Mode: Turns on when there is no interference in the detection zone (except when the muting function is used) Output: 2 outputs for PNP and NPN. It can be changed with a jumper cable. Max. Load current: 50 ...
used
Model: SolarEdge P800P INPUT (DC) Rated DC Input Power: 800W Absolute maximum input voltage (Voc): 83 Vdc MPPT Operating Range: 12.5 – 83 Vdc Maximum short-circuit current (Isc): 14 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION (optimizer connected to operational SolarEdge inverter) Maximum Output Current: 18 Adc Maximum output voltage: 85 Vdc STAND-BY OUTPUT (optimizer disconnected from inverter or inverter off) Safety output voltage for power optimizer: 1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3 Safety: IEC 62109-1 (Safety Class II), UL1741 Materials: UL-94 (V-5VA), UV resistant RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum permissible system voltage: 1000 Vdc Compatible SolarEdge inverter ...
used
Model: SolarEdge P800P INPUT (DC) Rated DC Input Power: 800W Absolute maximum input voltage (Voc): 83 Vdc MPPT Operating Range: 12.5 – 83 Vdc Maximum short-circuit current (Isc): 14 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION (optimizer connected to operational SolarEdge inverter) Maximum Output Current: 18 Adc Maximum output voltage: 85 Vdc STAND-BY OUTPUT (optimizer disconnected from inverter or inverter off) Safety output voltage for power optimizer: 1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3 Safety: IEC 62109-1 (Safety Class II), UL1741 Materials: UL-94 (V-5VA), UV resistant RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum permissible system voltage: 1000 Vdc Compatible SolarEdge inverter ...
used
Model: SolarEdge P404 INPUT (DC) Rated DC input power: 405W Absolute maximum input voltage (Voc at minimum temperature): 80 Vdc MPPT operating voltage range: 12.5 – 80 Vdc Maximum short-circuit current (Isc): 11 A Maximum efficiency: 99.5 % Weighted efficiency: 98.8 % Overvoltage category: II OUTPUT OPERATION (optimizer connected to operational SolarEdge inverter) Maximum Output Current: 15 Adc Maximum output voltage: 80 Vdc STANDBY OUTPUT (optimizer disconnected from SolarEdge inverter or inverter off) Safety output voltage for optimizer: 1 ± 0.1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3 Safety: IEC 62109-1 (Safety Class II), UL1741 RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum allowable system voltage: 1000 Vdc Dimensions (W × D × H): 129 × 153 ...
used
Model: SolarEdge P800P INPUT (DC) Rated DC Input Power: 800W Absolute maximum input voltage (Voc): 83 Vdc MPPT Operating Range: 12.5 – 83 Vdc Maximum short-circuit current (Isc): 14 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION (optimizer connected to operational SolarEdge inverter) Maximum Output Current: 18 Adc Maximum output voltage: 85 Vdc STAND-BY OUTPUT (optimizer disconnected from inverter or inverter off) Safety output voltage for power optimizer: 1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3 Safety: IEC 62109-1 (Safety Class II), UL1741 Materials: UL-94 (V-5VA), UV resistant RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum permissible system voltage: 1000 Vdc Compatible SolarEdge inverter ...
used
Model: SolarEdge P800P INPUT (DC) Rated DC Input Power: 800W Absolute maximum input voltage (Voc): 83 Vdc MPPT Operating Range: 12.5 – 83 Vdc Maximum short-circuit current (Isc): 14 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION (optimizer connected to operational SolarEdge inverter) Maximum Output Current: 18 Adc Maximum output voltage: 85 Vdc STAND-BY OUTPUT (optimizer disconnected from inverter or inverter off) Safety output voltage for power optimizer: 1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3 Safety: IEC 62109-1 (Safety Class II), UL1741 Materials: UL-94 (V-5VA), UV resistant RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum permissible system voltage: 1000 Vdc Compatible SolarEdge inverter ...
used
Model: SolarEdge S440 INPUT (DC) Rated DC input power: 440W Absolute maximum input voltage (module Voc at minimum temperature): 60 Vdc MPPT operating range: 8 – 60 Vdc Maximum short-circuit current (Isc) of the connected PV module: 14.5 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION Maximum Output Current: 15 Adc Maximum output voltage: 60 Vdc EXIT DURING STAND-BY Safety output voltage for power optimizer: 1 ± 0.1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15 Class B, IEC 61000-6-2, IEC 61000-6-3, CISPR 11, EN 55011 Safety: IEC 62109-1 (Safety Class II), UL1741 Materials: UL94 V-0, UV resistant RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum permissible voltage of the system: 1000 Vdc Dimensions (W × H × D): 129 × 155 × 30 mm Weig ...
maximum number of results exceeded