Flame pretreatment plant HILL EF 600-1

machines for plastic / peripheral equipment (e.g. heating,cooling,drying)

Manufacturer: HILL

Model:EF 600-1

Type of machine: Flame pretreatment plant

item-No.: 157609986

Quantity: 1

Date: 02.06.2025

Year of manufacture: 2006

Location: Land-at Austria 8055 Graz

Price:


1 pc flame pretreatment system with electronic control

1 pc EF 600-1
Burner control consisting of
Electrical control with ignition and monitoring device
for 1 pc burner, control electronics, control panel with plain text display,
Emergency stop setup and interface for external control
Mechanical control with
Safety valves, gas/air mixers,
thermoanemometrial mass flow meters for air and gas,
Engine valves, pressure monitors for overpressure and vacuum monitoring
and supply air blowers.
1 pcs C24-2300
Film burner, 2200 mm working width, adjustable up to min. 1000 mm
with connections for water cooling and water-cooled double T-beam
1 pc spare parts
consisting of 2 earth replacement electrodes and 1 replacement fabric

Power supply : 400/230 V 50 Hz, 2.5 kVA
Gas supply : Natural gas 75 – 100 mbar
Heat output : max. 400 kW
Gas consumption : max. 30 kg/h

here are the data of the system delivered in 2016.

1 pc burner control EF 300-1 FC

- Electrical control
with ignition and monitoring device for 1 burner, control electronics Siemens S7, control panel with plain text display, emergency stop device and interface for external control via Profibus DP ( slave )

- Mechanical control
with safety valves, gas/air mixers, mass flow meters for air and gas, engine valves, pressure monitors for over- and underpressure monitoring of the operating media air and gas, integrated, frequency-controlled supply air blower
Gas connection: 1 1/2" ball valve
Mixture connection to burner 3" female thread mixture distributor : input 3" 2 x output 2"

1 pc burner CE62-K-2100/800
Pretreatment burner for web stops in 120x140mm burner profile, variable working width 800 – 2100 mm due to cover slide internally, complete with ignition / monitoring electrode and flexible mixture supply cable
2 x 2 m NW 2" , connections for burner temperature control ( 40°C ), flow monitor for flow and return, temperature sensor on cooling water supply for burner
Cooling water connection: Flow 1/2" female thread, return 1/2" female thread
Burner mounting: Thread on the back of the burner Weight : approx. 100 kg

Specifications:
Power supply: 400V, 50Hz, 20kVA
Gas supply: propane or natural gas, 100 mbar, 45 m³/h at full load
Heat output: max. 200kW
Compressed air supply: - omitted because integrated supply air blower -
Dimensions : 2000mm x 2200mm x 800mm ( W x H x D )
Paintwork: RAL 7035
Temperature control on the customer's side : Cooling medium water, temperature controlled to 40°C
Customer suction : 7000-10000m³/h, delta P - 52,5 mbar / 5250Pa
Suction temperature: max. 110 °C
Cooling roller diameter : min. 300 mm
Share this machine on Facebook:

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

Copy to you?

Save input data

1 pc flame pretreatment system with electronic control

1 pc EF 600-1
Burner control consisting of
Electrical control with ignition and monitoring device
for 1 pc burner, control electronics, control panel with plain text display,
Emergency stop setup and interface for external control
Mechanical control with
Safety valves, gas/air mixers,
thermoanemometrial mass flow meters for air and gas,
Engine valves, pressure monitors for overpressure and vacuum monitoring
and supply air blowers.
1 pcs C24-2300
Film burner, 2200 mm working width, adjustable up to min. 1000 mm
with connections for water cooling and water-cooled double T-beam
1 pc spare parts
consisting of 2 earth replacement electrodes and 1 replacement fabric

Power supply : 400/230 V 50 Hz, 2.5 kVA
Gas supply : Natural gas 75 – 100 mbar
Heat output : max. 400 kW
Gas consumption : max. 30 kg/h

here are the data of the system delivered in 2016.

1 pc burner control EF 300-1 FC

- Electrical control
with ignition and monitoring device for 1 burner, control electronics Siemens S7, control panel with plain text display, emergency stop device and interface for external control via Profibus DP ( slave )

- Mechanical control
with safety valves, gas/air mixers, mass flow meters for air and gas, engine valves, pressure monitors for over- and underpressure monitoring of the operating media air and gas, integrated, frequency-controlled supply air blower
Gas connection: 1 1/2" ball valve
Mixture connection to burner 3" female thread mixture distributor : input 3" 2 x output 2"

1 pc burner CE62-K-2100/800
Pretreatment burner for web stops in 120x140mm burner profile, variable working width 800 – 2100 mm due to cover slide internally, complete with ignition / monitoring electrode and flexible mixture supply cable
2 x 2 m NW 2" , connections for burner temperature control ( 40°C ), flow monitor for flow and return, temperature sensor on cooling water supply for burner
Cooling water connection: Flow 1/2" female thread, return 1/2" female thread
Burner mounting: Thread on the back of the burner Weight : approx. 100 kg

Specifications:
Power supply: 400V, 50Hz, 20kVA
Gas supply: propane or natural gas, 100 mbar, 45 m³/h at full load
Heat output: max. 200kW
Compressed air supply: - omitted because integrated supply air blower -
Dimensions : 2000mm x 2200mm x 800mm ( W x H x D )
Paintwork: RAL 7035
Temperature control on the customer's side : Cooling medium water, temperature controlled to 40°C
Customer suction : 7000-10000m³/h, delta P - 52,5 mbar / 5250Pa
Suction temperature: max. 110 °C
Cooling roller diameter : min. 300 mm

seller offer No. resale 157609986
Share this machine on Facebook:

Seller


verified user

RESALE member since 2021

For more information about the seller, please send him an enquiry and select the option "Copy to you?".

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

(to all dealers for such a machine)

Copy to you?

(copy of your inquiry will be sent to your email address)

Save input data

(Save input data for further inquiries)