used
Centrax 501 KB57 DLE Gas Turbine-Generator Package engine overhaul in 2017 at 24 000 hours 372 start service hours 23 000
used
Natural Gas Turbine Brand Centrax Mod. 501 KB7 Year 2012 50 Hz Wattage 5.3 Voltage 6300 13,600
used
gas turbine Turbomeca MAKILA TI POWER 1 MWe year 2000 hours 6400 Soundproof turbine box,
used
GAS TURBINE CENTRAX PACKAGE OR ONLY CORE YEAR 1990 HOURS 40 000 PRICE LOADED IN FRANCE
FOR SALE GAS TURBINE Tempest SGT300 packaged 7941 kva year 2000 50 HZ VOLT 11 000
hello for sale 2 units turbine in trailer Technical Specifications Model: Rolls-Royce Allison 570KA Year of manufacture: 2005 Fully overhauled: 2012 Commissioned: 2016 Operating hours since 2016: Only 81 hours Fuel type: Gas Power output: 4,400 kW Mounted on trailer: Yes Additional trailer: UPS trailer included Location: Paris, France loaded now Availability: Immediate Documentation: Complete (technical & maintenance records)
used
GAS TURBINE PACKAGE – GE LM 6000 PD 48 MW 1. General Information Equipment: Industrial Gas Turbine Package Manufacturer: GE Model: LM 6000 Year: 2002 Hours : 38 000 Condition: Used – Good Operating Condition loaded in france
used
FOR SALE CORE TURBINE CENTRAX 501 KB5 I don't have any more information since the factory has closed LOADED NOW IN FRANCE GOOD PRICE
used
Back-pressure turbine Manufacturer: Fa. KKK First Start-up: 2002 Operating Hours of Turbine: 30,000h Type: CFR5 G6a Power Max: 2500 kW Operational efficiency: 2200 kW Revolution number: 23000 rpm Live steam pressure: 65 bar Live steam pressure temperature: 480 oC Evaporation pressure: 1-17 bar Investments in the year 2002 Entire steam transforming station from 63 bar to 2.5 bar renewed in 2002, El. Generator Leroy Somer, el. Power 2 MW Renewed measuring Entire -, governing and control of the turbine renewed Steam turbine renewed Installed boiler efficiency: Boiler I Hard coal Steam generation: 20 t/h, 63 bar, 495 oC Boiler II Hard coal Steam generation: 13 t/h, 34 bar, 425 oC Boiler III: Combination burner for oil and gas Steam generation: 20 t/h, 17 bar, 285 oC General overhaul of the entire plant from 2002 to 2004 Steam generator renewed automatic cole-loader ...
used
One used AEG Kanis G 20 back pressure steam turbine from 1985 in good running condition. The steam inlet pressure of 14 bar can be increased up to 20 bar. Alternators with other voltages are also available on request. For Sale type: AEG-Kanis G20 el. power: 2046 KW generator end: AEG 2650 KVA, 5250 Volts, 50 Hz, cos phi 0,8 steam consumption: 40 to/h at full load steam inlet pressure: 14 bar (up to 20 bar possible) back pressure: 4,5 bar inlet steam temperature: 320 °C gear ratio: 8,04 manufactured: 1985 mesurements: 8,30 L 3,00 H 4,2 W price on request: Here you can download all the turbine pictures (30 MB): abc.stromerzeuger-discount.de/AEG-Kanis_G20_back_pressure_2046_kw_stea m_turbine_14_bar/all_pictures.zip Here you can download the scope of supply (13 MB): abc.stromerzeuger-discount.d ...
used
Dear's Sale, T/C complate ABB TPS 52 Recon, Good condition Regards +905323642509 info@kscege.com
used
Turbine Turbine operating hours: 30,000h Backpressure turbine Manufacturer: Kkk First start-up: 2002 Type: CFR5 G6a Power max: 2500 kW Operating efficiency: 2200 kW, Number of revolutions: 23000 rpm, Live steam pressure: 65 bar, Live steam pressure temperature: 480 C, Evaporation pressure: 1-17 bar, Investments in 2002 , Entire steam transformation station renewed from 63 bar to 2.5 bar in 2002, El. Generator Fa. Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA, renewed, complete measurement, control and control of the turbine renewed, steam turbine renewed with energy production General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic corder and ash removal system renewed, water treatment plant renewed, complete instrumentation renewed, flue gas cleaning plant Lurgie renewed from 1991 - 2001 Mistakes excepted!
used
Price on request. FCA free loaded in our warehouse. One second hand Siemens Twin AFA 46 condensing steam turbine manufactured in 2009 for sale. turbine: Siemens type: Twin AFA 46 el. power: 3.300 KW running hours: steam consuption: steam inlet pressure: 26 bar inlet steam temperature:400°C manufactured: 2009 generator: AVK powerrating: 4.125 KVA volts: 6.300 volts Hz: 50 Hz price on request: Stromerzeuger-Discount Kürtener Straße 13 D-51465 Bergisch Gladbach Mobile: 0049/1635263546 Telefon: 0049/ 2202 2492256 Fax: 0049 2202 2492257 Email: info@stromerzeuger-discount.de
used
1300 KW KK&K CFR3 G5A tandem condensing steam turbine 40 bar inlet pressure from 1997 with 50.000 running hours in very good working condition for sale. Scope of supply: controlpannel, turbine with generator, documents. turbine: KK&K type: CFR3 G5A el. power: 1300 KW steam inlet pressure: 40 bar manufactured: 1997 generator: AEM type: SE 500 M4 powerrating: 1830 KVA volts: 400 volts Hz: 50 Hz price on request: Stromerzeuger-Discount.com Kürtener Straße 13 D-51465 Bergisch Gladbach Mobile: 00491635263546 Telefon: 0049 2202 2492256 Fax: 0049 2202 2492257 Email: info@stromerzeuger-discount.de
used
3692 KW Dresser Tuthill Nadrowski Tandem Condensation Turbine (steam turbine)for sale. 58.000 € plus VAT FCA freely charged in D-Bergisch Gladbach. Scope of supply: Steam turbo set and generator (6 KV). On request, generators with 10 to 11 KV are also available. A suitable capacitor costs 75,000 € extra. Not included: Control. Brand: Leroy-Somer Manufacturer: Tuthill Nadrowski Turbinen GmbH Type: LSA 56 BS 5- 4P Serial No.: 168233-1 Year of construction: 12-2001 Electr. Power: 3692 KW Power: 4625 KVA Voltage: 6000 V rpm: 1500 rpm Size (L x W x H): 3.10 m x 1.80 m x 2.70 m Weight: 10,000 kg Total output HD and ND turbine: 3692 KW. Total weight steam turbo set: 15 tons + 10 tons generator.
used
2 used steam turbine units available: 1. Type: B5 S2 + G IV Year: 1991 Turbine output: 294 kW at 1.35 bar and 170 C With exhaust gas heat exchanger 2. Type: B5 S3 + G IV Year: 1992 Turbine output: 330 kW at 1.35 bar and 170 C With exhaust gas heat exchanger Subject to prior sale - Errors possible
used
MAN NR34/S026 Turbocharger 1 new and 3 used available New bearings and repair sets also available in our stock in Istanbul Please contact: info@fin-marine
used
1 piece ABB TPL 77-B12 turbocharger complete available New In our stock in Istanbul Please contact: info@fin-marine
used
used
MBARBECOL turbine flap PN-5478 MAN 28/32 engine Just the turbine hull.
used
Kawasaki M7A-03D 7.2MW Natural Gas Turbine Complete CHP Generating Set Completely self-contained Kawasaki M7A-03D 7.2MW Gas Turbine and Generator package with Heat Recovery (Thermic Fluid Heater and HRSG Hot Water Generator) in acoustic enclosure. Runs parallel with grid. Island operation mode. Make and Model: Kawasaki TD80A Capacity: 7200kW Hrs: 10,000 V: 11,000 HZ: 50 Year: 2010 Fuel: Natural Gas Scope of supply : Gas Turbine GPB 80, M7A-03 DLE Single Gas Fuel, single shaft with DLE Combustor, reduction gear box, coupling with guard, Diaphragm Type, Generator (TD80A, 2011) Heat Recovery System - Thermic Fluid Heater, HRSG Hot Water Generator Acoustic Canopy with Lighting Control and Instrumentation Exhaust collector and/or diffuser, Gas Fuel system, Lube oil system, Inlet ducting, Inlet filtration system, Inlet silencer, Combustion system, Protection syste ...
new
Discover an exceptional opportunity to acquire a new and unused Siemens Steam Turbine, perfectly suited for high-efficiency power generation: - Voltage: 11kV - Frequency: 50Hz - Speed: 1500rpm - Blower: Howden SO2, powered by a Siemens motor with a robust 2200kW capacity. - Condenser: High-efficiency Shell and Tube type for superior heat exchange. - Condensate Extraction: Sigma pump ensuring effective condensate management. - Vacuum Pump: Invatech water ring vacuum pump for optimal system performance. - Steam Generator: Clayton E-1204-SH, known for its reliability and efficiency in steam production. - Deaerator and Blowdown Tanks: Depression models to safeguard system integrity. - Boiler Feed Pumps: Hammelmann, designed for consistent and reliable water supply to the boiler. - Boiler Booster Pumps: Flowserve, enhancing the system's pressure cap ...
used
Centrax ROLLS ROYCE 5 MW CX 501 KB7 Gas Turbine-Generator Package YEAR 2011 HOURS 40 000 Equipment List: Turbine/Alternator Housing and its complete contents including: • 1 Allison 501 KB7S DLE Gas Turbine - • 1 Alternator • 1 Epicyclic Gearbox • 1 Acoustic Enclosure • 1 Alternator Control Cabinet and Software • 1 Turbine Control Cabinet and Software • 1 Auxiliary Distribution Cabinet and Software • 1 Lubrication Unit including Oil Cooler • 1 Fuel Supply Circuit in Acoustic Enclosure • 1 Electro-Hydraulic Starting System- • 1 Compressor Cleaning System • 1 DC Power Supply • Battery Charger • Fire Protection and Gas Detection Circuit • Fan acoustic enclosure • Air cooler fan List of components: • Control/command panel and room and its complete contents • Filtration assembly and combustion air ducts • Filtration assembly, silencers and box ventilat ...
used
1 x Steam turbine generator 3817 KW KKK Siemens CFR5 G6b 5,000 KWe x 1,500 rpm 50 Hz 6,300 V for sale in operational condition Turbine Manufacturer KKK Siemens Model CFR5 G6b Steam pressure fresh [bar] 64 Dampfdr. Ed. [bar] 8.5 Generator Manufacturer INDAR Model BZK-710-S/A-4 P Generator [KW] 5.000 Turn around. [per min] 1,500 Frequency [per sec] 50 Voltage [V] 6,300 Current [A] 458 Scope of delivery: The system has been completely dismantled and is complete including the control system. Technical documentation: available Spare parts / tools: not available The plant was dismantled in working order. Last major overhaul: unknown Sales are "as is" or after prior inspection by a company engaged by us on request
used
Available in stock 1 x Used Capstone TET. The unit is used but in good working conditions. Note: We have several Capstone parts in our stock to sell. If you are looking for something in particular, please contact us and we will see if we have anything to fulfill your request.
used
537 KW Tuthill Nadrowski back-pressure steam turbine C4. S-GIII from 2004, only turbine (was used as a pump). 1 available inlet pressure 90 bar, outlet pressure 18 bar, Price: € 19,500 each, plus VAT and FCA-free Manufacturer: TUTHILL Nadrowski Model: C4. S-G III Type: Steam Back Pressure Serial Number: 21004 Power [kW]: 537 Pressure inlet [bar]: 90 Pressure outlet [bar]: 18 Speed (rpm) 3.554 Year of construction: 2004 Weight [kg]: 2.440 Dimensions LxWxH [cm]: 370x138x174
used
Details of the equipment offered: • 1 Rolls Royce Type 501K-2044 turbine – ASP Engine Model 501-KB7, with sound-absorbing box • 1 ALEN GEARS Type STAR speed reducer – ASG34 • 1 Leroy Somer LSA 56 BUL85-4p / 6750 KVA alternator – 50 Hz • Natural gas control system • Box ventilation system • Electrical control cabinet • Fire Suppression System • Flue gas and water recovery boiler • Compressed air control system Characteristics: • Year of manufacture: 1999 • Total hours of service: 43,000 hours • Equipment still in operation, maintenance monitored by the manufacturer • Loading from France Overhauled in 2023 Photos and video available on request: This package represents an interesting opportunity for any company looking for a reliable and immediately operational solution. Do not hesitate to contact us for any further information, ...
new
Steam turbine Siemens SST400 Year: 2011 Disassembled and put in a storage. Very low working hours. Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Turbo gear unit Flender-Graffenstaden TX80/3 Transformer Siemens S10-40000/110 Condenser Full set of manual books No boilers, no voltage control cabinet (7) Steam turbine Siemens SST-400 Year: 2011 Never used and never installed. Still in original wooden crates. Packing lists. 7 sets available Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Control system Accessories Full set of manual books No boilers Price: on request
used
Kaplan turbine Escher Wass with standing shaft, used very good condition Gradient 7.00m-7.2 m Water volume 6000l/sec, power 500 hp, speed 375T/min
used
Taurus 60 Turbine Generator Set Solar Taurus 60 T7301 Gas Turbine Engine Runnig hour 1165 hour after last Overhaul Output Power 5200 Kw Gearbox Solar Gear Unit 1165 hour after last Overhaul Type: Epicyclic Leroy Somer Generator 50 Hz
used
6.6 MW MAN THYSSEN Extraction Condensing Steam Turbine Manufacturer: MAN THYSSEN Year of Construction: 1999 Condition: Used – In Good Running Condition Availability: In Stock Technical Data: Rated Power Output: 6.6 MW Voltage: 11 kV Frequency: 50 Hz Steam Inlet Conditions: Pressure: 40 bar Temperature: 440 °C Extraction Performance: 6 MW with 50 t extraction – 65 t/h 6 MW with 16 t extraction – 45 t/h 5 MW with 0 t extraction – 28 t/h Extraction Steam: Pressure: 12 bar Temperature: 294 °C Exhaust Steam: Pressure: 0.25 bar Temperature: 65 °C Description: Well-maintained German manufactured extraction condensing steam turbine suitable for industrial power generation and combined heat and power applications. The unit is designed for continuous operation and is ideal for sugar mills, textile plants, paper mills, chemic ...
used
10 MW W H-ALLEN Bedford England Back Pressure Steam Turbine Manufacturer: W H-ALLEN, Bedford, England Type: Back Pressure Steam Turbine Condition: Used – In Good Industrial Condition Availability: In Stock Technical Specifications: Rated Power Output: 10 MW Rated Speed: 7,750 RPM Voltage: 11 kV Frequency: 50 Hz Steam Conditions: Inlet Steam Pressure: 44.8 bar g Inlet Steam Temperature: 400 °C Exhaust Steam Pressure: 1 to 5.2 bar g Heavy-duty British-manufactured back pressure steam turbine designed for continuous industrial power generation and process steam applications. This unit is suitable for combined heat and power systems in sugar mills, textile plants, paper mills, chemical industries, and other steam-based manufacturing facilities. The turbine operates at high efficiency with stable back pressure performance, making it ideal for facili ...
used
20 MW STAL-LAVAL Industrial Steam Turbine Generator Set Manufacturer: STAL-LAVAL (Sweden) Type: Industrial Multi-Stage Steam Turbine Configuration: Condensing / Extraction-Condensing Manufacturing Era: Circa 1963–1964 Condition: Industrial Condition – Available for Inspection Availability: In Stock Power & Electrical Data: Rated Output: Approx. 20 MW Frequency: 50 Hz Rated Speed: 3000 RPM Generator: STAL-LAVAL GTP Series Generator Poles: 2-Pole Turbo Alternator Cooling System: Radial-flow air ventilation with filtration Coupling: Direct-coupled turbine-generator set Steam Design Parameters: Steam Pressure Class: Approx. 65 bar Steam Temperature (Design): Approx. 480–520 °C Operating Mode: Condensing turbine with surface condenser (extraction capable) Exhaust System: Shell and tube surface condenser Technical Features: Curtis con ...
used
Manufacturer: AEG Germany Equipment Type: Back Pressure Steam Turbine Generator Power Output: 11,200 kVA (≈ 9 MW) Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Type: S 688/4 Condition: Available As-Is, Where-Is Technical Specifications Electrical Output: 11,200 kVA (9 MW) Inlet Steam Pressure: 65 bar Inlet Steam Temperature: 440 °C Steam Consumption (Full Load): 60 tons/hour Exhaust Steam Pressure: 2.5 bar (Max) Exhaust Steam Temperature: 190 °C Voltage: 6.5 kV Frequency: 50 Hz Speed: 3000 RPM Generator Insulation Class: B Description High-capacity AEG Back Pressure Steam Turbine Generator designed for industrial power generation and energy recovery applications. This 9 MW steam turbine system is suitable for industries with continuous steam availability such as: Sugar mills Textile mills Chemical plants Paper mil ...
used
Dear Ladies and Gentlemen, We constantly have transformer stations for wind turbines in every power and voltage.
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -from: scrubbing machine make Gansow -Number: 17x available -Price: per piece -Dimensions: Ø 145/H210 mm -Weight: 2.7 kg
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner -Manufacturer: Lamb Electric, suction motor from Gansow scrubber-dryer -Voltage: 24 V -Quantity: 29x available -Price: per piece -Dimensions: Ø 145/H175 mm -Weight: 2.3 kg/pc.
used
Vacuum cleaner motor, suction turbine, wet vacuum cleaner, suction motor -Manufacturer: Ell, suction motor from scrubber dryer Gansow 70 BF 70 -Type: 500W -Voltage: 24 V -Quantity: 1 available -Dimensions: Ø 147/H210 mm -Weight: 2.8 kg
used
Ansaldo Condensing Steam Turbine Power: 9000 kW RPM: 7500 / 1500 Steam pressure: 40bara Steam temperature: 420 ºC Back Pressure: 0,08bar Number of extractions: 2 Number of stages: 8
used
used
used
BVI / ThyssenKrupp Condensing steam turbine MARC6-C03 2005 power generator with 135,000 operating hours, without steam condenser and AC generator. Inlet pressure 89 bar, outlet pressure 0.11 bar, 21,000 KWel x 1,500 rpm, Steam turbine BVI / ThyssenKrupp MARC6-C03 Manufacturer: BVI / ThyssenKrupp Model No.: MARC6-C03 Type: Steam Condensation Serial number: P-900078 Power [KW]: 23,545 Pressure Input [bar]: 89 Temperature Input [°C]: 520 Pressure output [bar]: 0.11 Year of Make: 2005 Hours: 135,000 Weight [kg]: 58,000 Dimensions LxWxH [cm]: 510x400x340
used
3X Identical Steam Turbine sets Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required. The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz. Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine. The unused steam turbine sets are pa ...
used
Mitsubishi Heavy Industries Ltd Type - SC1F ( Single Cylinder Single Flow ), Condensing Steam Turbine Power : 205.440MW HP Steam : 85 ata, 538 C LP Steam : 5.5 ata 193 C Steam Turbine Generator Model : MB-H Power - 241, 680 KVA Voltage - 16.5KV, 50 Hz
used
Model: Avon 1533-56L Year of Manufacture: 1992 Type: Aeroderivative Gas Turbine Rated power: Approximately 16,347 kW (22,225.73 hp) to 17,007 kW (23,123.08 hp) DIRECTINDUSTRY Thermal Efficiency: Up to 44% Dimensions: Length: Approx. 3,200 mm Diameter: approx. 907 mm Weight: Approximately 1,310 kg
used
Capacity: 3,224 kW Volts: 400 HZ: 50 Condition: Very Good Scope of Supply: Complete Turbine Power Station with turbine and alternator, Control Panel, Condensor, Cooling Towers, Spilling Unit, Switchgear, Synchronisation panel, Transformer, Piping / wiring / pumps. Total cost for power plant components was around 3 million on the actual power plant components. Nominal Steam requirement to run the turbine is 17, 5 t/h at 29 barg & 350 °C. Available for sale from Gas Engine Exchange . Please check our full range of equipment at gasengineexchange.com.
used
Heating output: 42.8kW, tank capacity: 51l, fuel: heating oil, oil consumption: 3.63kg/h, blower output: 1600m³/h. An on-site inspection is possible.
used
APE gearbox (Dualbox) geabox Type: Planetary Epicenclic Reducer Brand: APE Allen Gears (UK) Reduction Ratio: 2.247:1 Input Speed: 14,210 RPM Output Speed: 1500 RPM Rated power: 860 kW (service: 3355 kW) Type: Epicacyclic (Planetary) Model: APE 43 Reduction Ratio: 2.247:1 Rated power: 860 kW Power in service: 3355 kW Input speed: 14210 rpm Output speed: 1500 rpm