dimensions
– Height (soundproofed) [mm] 930
– Height (supersonic insulated) [mm] 2120
– Width (acoustic/supersound-insulated) [mm] 1200
– Depth (acoustic/supersound-insulated) [mm] 980
weight
– soundproofed [kg] 315
– supersound-insulated [kg] 365
Highest sound pressure level [± 3 dB(A)]
according to DIN 45635, part 13 86/79
– schallg. / supersound-insulated [dB(A)]
Measuring area measure 15/15
schallg. / supersound-insulated [dB(A)]
Formwork power level 101/94
– schallg. / supersound-insulated [dB(A)]
compressor
compression final temperature [°C] 110
Volume flow to
PN 2 CPTC 2 at:
– pmax = 8 bar [m3/min] 3.35
– pmax = 10 bar [m3/min] 2.85
– pmax = 13 bar [m3/min] 2.45
Motor
Rated power [kW] 22
rated speed
– 50 Hz [min-1] 3000
– 60 Hz [min-1] 3600
Protection class IP 55
Design IMB 3
ISO Class F
Electrical connection
Mains voltage 1) [V] 400
Frequency 1) [Hz] 50
Minimum collateral 2) [A] 50
recommended pre-fuse 2) [A] 63
Oil filling quantities
Oil tank volume [l] 18
Total oil filling quantity [l] 9
Oil refill quantity
between min. + max. [l] 1.5
Intake air temperature
– min. [°C] + 5
– max. [°C] + 40
Cooling air requirements
– free installation [m3/h] 7600
– with supply and exhaust M51252847 air duct [m3/h] 3800
– free fan pressing [Pa] 50
– free fan pressure [mm WS] 5
Operating pressure switch 2)
(factory settings)
– pmax = 18 bar: switch-off pressure pmax [bar] 8
On-shift pressure pmin [bar] 7
– pmax = 10 bar: switch-off pressure pmax [bar] 10
On-shift pressure pmin [bar] 9
– pmax = 13 bar: switch-off pressure pmax [bar] 13
On-shift pressure pmin [bar] 12
safety valve
Response pressure at:
– pmax = 8 bar [bar] 11
– pmax = 10 bar [bar] 11
– pmax = 13 bar [bar] 14
Technical data subject to actual equipment