We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
128,039 used machines on RESALE, but how to find them? Machine Search
used
() is equipped with an insulated - and is ideal for industrial cooling processes. It has two powerful fans and integrated piping and controls. The coolant is glycol, and the refrigerant used is R-410A. The system offers a cooling capacity of 14 kW at an . () . (). The 5.5 kW electric motor operates at 380–415 V, 50 Hz, and 20 A current consumption. This compact unit enables efficient, reliable cooling in industrial processes. Our team at VBW Asset Trade will be happy to answer your questions., Additional title: externally mounted cooling unit with glycol buffer storage tank, Cooling capacity: 14 kW, Pressure compressed: 4,2 bar, Pressure relaxed: 1,9 bar, Gross volume glycol buffer tank: 400 l, Power: 5,5 kW, Current: 20 A, Voltage: 380-415 V, Frequency: 50 Hz, Features: Cooling unit with 2 fans, glycol storage tank, piping, control system
used
Descending spiral, infeed at the top, outfeed at the bottom, Belt width gross: 920 mm, Belt width nett: 880 mm, Tiers: 23 pcs., Link height: 80 mm, Product gap: 65 mm, Length per tier: 17.8 m, Belt length: 409 m, Refrigerant: NH3, ammonia, Evaporator size: 1800 m2, 975 L, Cooling power: 250 kW, Power: 3 x 400V, 50Hz, 64 kW
used
NH3 refrigeration system for cooling glycol and brewing water, consisting of the following components: - NH3 separator brewing water 890 l (T0 = -0.5°C) - NH3 separator glycol 647 l (T0 = -6 °C) - 3 x piston compressors (Bitzer type W4GA) - 2 x brewing water pumps - Plate heat exchanger as brewing water cooler Q0 = 200 kW - Evaporation condenser - Water tank approx. 470 hl - Glycol tank 80 hl + 2 x glycol pump - Plate heat exchanger as glycol cooler Q0 = 100 kW - High pressure collecting vessel 830 l - Danfoss frequency inverter type VLT HVAC, Additional title: NH3 Cooling plant, Cooling capacity Q0 brew water: 200 kW, Cooling capacity Q0 glycol: 100 kW, Evapotation temperature t0 brew water cooling: 0 °C, Evaporation temperature t0 glycol cooling: -6 °C, Current: 185 A / 250 A, Features: 2 x NH3 separators (t0 = -0.5 °C; t0 = -6 °C); 3 x piston compressors; 2 x brewing water pumps ...
used
Stainless steel floor, central lubrication system, Belt width gross: 1060 mm, Belt width nett: 1015 mm, Tiers: 40 pcs., Link height: 80 mm, Product gap: 65 mm, Belt length: 820 m, Max belt load: 18 kg/m2, Infeed height: 925 mm, Outfeed height: 4500 mm, Refrigerant: nh3, ammonia, Cooling power: 400 kW, Evaporator surface: 4000 m2, Power: 3 x 400V, 50Hz, 92kW, Dimensions: 13050 x 9450 x 5300 mm
used
Including:, Goedhart BV evaporator, Type: LLK.s 411m², Year of construction: 2010, Capacity: 135 dm³, Refrigerant: NH3, Working pressure: 22 bar, Test pressure: 32 bar, Weight: 770 kg, Belt width nett: 940 mm, Tiers: 3, Belt length: 5800 mm, Power: 3 x 380V, 50Hz, 0.37kW, Dimensions: 7200 x 1400 x 2900 mm, Weight: 2850 kg
used
Ice water generator for cooling supply of wort cooler (2nd stage), fermentation cellar (= 100 hl capacity), storage cellar (= 320 hl capacity) and pressure tanks (= 260 hl capacity) in a microbrewery with 20 hl output., Additional title: ice water generator, Cooling capacitry: 14 kW, Power: 6,2 kW, Length: 1600 mm, Width: 1600 mm, Height: 1800 mm, Position: free standing, Base construction: cylindrical tank with refrigeration unit on top, on square tube frame with domes, Features: insulated stainless steel tank with side cover, semi-hermetic reciprocating piston compressor, copper tube coil exchanger, control box, cooling water pump
used
Refrigeration plant with 70 kW complete with compressor, condenser, in-house cooling tower, plate heat exchanger for glycol cooling and control cabinet. Refrigerant: Ammonia, Additional title: Refrigerant: Ammonia, Cooling capacity: 70 kW, Design to: -8 °C, Design tc: 27 °C, Power: 15 kW, Operation / Control: Control cabinet with hardware control, Features: Compressor, condenser, plate heat exchanger, glycol cooler, in-house cooling tower, control cabinet
used
Technical data Model: FLKS-340S Media temperature: max. 60 °C Ambient temperature: 0 °C to +40 °C Noise level according to DIN 45635 T1: 74 dB(A) at 50 Hz (4-pole), 77 dB(A) at 60 Hz Weight: 66 kg Configuration Direction of rotation pump: right (view of motor fan) Direction of rotation fan: left (view of fan wheel) Tank capacity: max. 16.5 l / min. 13.5 l Standard: DIN 45635 T1 incl. pallet, pack size (LxWxH) approx: 1200x800x1200 mm Auction-ID: A1-48287-3
used
This lot is part of the final combination: 12 (1 to 11) Auction-ID: A1-48525-10
used
comes with European papers - fully furnished with stainless steel cabinets - 150l cooling - hot and cold water tap - water tank for clean and dirty water - stainless steel worktops - floor drain for cleaning - electrical supply and sufficient sockets Auction-ID: A3-46194-10187