Maximum removal of impurities. Increased quality of the final product.
Extended service life of the operating process. High reliability. Low
pressure loss. Service-friendly. Tested according to applicable ISO
standards.
Filter package
Replace filter G85 1/2" residual oil 0.3 mg/m³ after 2000 hours
Replace filter C85 1/2" residual oil 0.01 mg/m³ after 2000 hours
Replace filter V85 1/2" residual oil 0.003 mg/m³ after 1000 hours
Residual oil after filter package 0.003 mg/m³ = technically
oil-free
+ Wall bracket
+ Connection kit
Filter G
Equipment in detail
Drain: Automatic float drain valve
Performance data
Nominal capacity 1.42 m³/min
Application: Oil Aerosol
Oil aerosol concentration in the outlet 0.3 mg/m³
Total mass efficiency >99.25 %
Quality class of air at the outlet (oil) 3 according to ISO
8573-1:2010
Pressure loss dry 55 mbar
Pressure loss wet 125 mbar
Element change 8000 h (or annually)
Installation data
Installation length 70 mm
Filter length 231 mm
Maintenance clearance (bottom) 70 mm
Weight 0.6 kg
Compressed air connection 1/2 "
Enclosure Connection Bottom 1/4"
min. / max. operating pressure 1.5 / 16.0 bar(g)
min. / max. compressed air inlet temperature 0 / 80 °C
Reference conditions
Inlet pressure 7 bar(g)
Ambient temperature 20 °C
Inlet temperature 20 °C
Inlet DTP 10 °C
Oil aerosol inlet concentration 40 mg/m³
Filter C
Equipment in detail
Drain: Automatic float drain valve
Performance data
Nominal capacity 1.42 m³/min
Application: Oil Aerosol
Oil aerosol concentration in the outlet 0.01 mg/m³
Overall Mass Efficiency >99.9%
Quality class of air at the outlet (oil) 2 according to ISO
8573-1:2010
Pressure loss dry 85 mbar
Pressure loss wet 125 mbar
Element change 8000 h (or annually)
Installation data
Installation length 70 mm
Filter length 231 mm
Maintenance clearance (bottom) 70 mm
Weight 0.6 kg
Compressed air connection 1/2 "
Enclosure Connection Bottom 1/4"
min. / max. operating pressure 1.5 / 16.0 bar(g)
min. / max. compressed air inlet temperature 0 / 80 °C
Reference conditions
Inlet pressure 7 bar(g)
Ambient temperature 20 °C
Inlet temperature 20 °C
Inlet DTP 10 °C
Oil aerosol inlet concentration 10 mg/m³
Filter V
Equipment in detail
Drain: Manual drain
Performance data
Nominal capacity 1.42 m³/min
Application: Oil vapor
Oil aerosol concentration in the outlet 0.003 mg/m³
Quality class of air at the outlet (oil) 1 according to ISO
8573-1:2010
Pressure drop dry 115 mbar
Element change 1000 h (or 1/2 annually)
Installation data
Installation length 70 mm
Filter length 231 mm
Maintenance clearance (bottom) 70 mm
Weight 0.6 kg
Compressed air connection 1/2 "
Enclosure Connection Bottom 1/4"
min. / max. operating pressure 1.5 / 20.7 bar(g)
min. / max. compressed air inlet temperature 0 / 50 °C
Reference conditions
Inlet pressure 7 bar(g)
Ambient temperature 20 °C
Inlet temperature 20 °C
Oil Aerosol Inlet Concentration 0.01 mg/m³
Applicable standards
The definition of compressed air quality is based on ISO
8573-1:2010.
The filters offered are produced according to high technical standards
and are designed to achieve the values set out in the standard and
maintain them with correct maintenance.
Their effectiveness is tested according to the execution according to
various ISO test methods.
- ISO 12500 was introduced specifically for compressed air treatment
elements in compressed air and completes ISO 8573
- ISO 8573-2: describes the measurement method (according to TÜV) of
downstream sampling for oil coalescence filters
- ISO 12500-1: describes inlet conditions, filter test setup, pressure
drop measurement for oil coalescence filters
- ISO 12500-3: describes inlet conditions, filter test setup, pressure
drop measurement for dust filters
- ISO 8573-5: describes the measurement method of downstream sampling
for oil vapor filters
Technical changes reserved.
Symbolic image – may differ from the listed product.