Detailed manual attached Including 25 pieces DANFOSS ALLY Radiator Thermostat Single piece loading dimensions: 850 x 530 x 300 mm Auction-ID: A7-47781-360
used
Composed of: - heat pump ( OMNIA UE 3.2.3) - hybrid boiler (OMNIA S HYBRID 28C 3.2) - Coaxial hoses + bends + hybrid hydraulic kit Loading dimensions : 1200x900x1300 mm Auction-ID: A7-47781-137
used
Detailed manual attached Loading dimensions: 600 x 410 x 210 mm Auction-ID: A7-47536-515
used
Manual detailed in description Single workpiece loading dimensions: 550 x 600 x 1500 mm Auction-ID: A7-47781-390
used
Model: REC370NP2 GENERAL DATA Cells: 120 N-type monocrystalline half-cut cells, 6 strings of 20 cells in series Glass: 3.2mm solar glass with anti-reflective surface treatment Backsheet: high-strength polymer construction Frame: Black anodized aluminum Junction box: 3 parts, 3 by-pass diodes, IP68 according to IEC 62790 Cables: 4 mm² solar cable, length 1.1 m (+) / 1.2 m (−), conforms to EN 50618 Connectors: Stäubli MC4 PV-KBT4 / KST4 (4 mm²), IEC 62852 compliant, IP68 when connected Origin: Made in Singapore MECHANICAL DATA Dimensions: 1755 × 1040 × 30 mm Area: 1.83 m² Weight: 20.0 kg ELECTRICAL DATA – STC Rated power Pmax: 370 W Classification tolerance: 0 / +5 W Voltage at maximum power Vmp: 34.7 V Current at maximum power Imp: 10.68 A Open circuit voltage Voc: 41.1 V Isc Short Circuit Current: 11.41 A Module efficiency: 20.3 % OPERATING LIMITS Operat ...
used
used
Detailed manual attached Loading dimensions: 600 x 410 x 210 mm Auction-ID: A7-47536-523
used
Single piece loading dimensions: 80 x 80 x 80 mm Auction-ID: A7-47536-575
used
Detailed manual attached Loading dimensions: 580x580x1280 mm Auction-ID: A7-47781-119
used
Model: SE-MTR-3Y-400V-A ELECTRICAL SERVICE Operating voltage range (line-neutral / line-to-line): rated 230 / 400 Vac, 184–264.5 / 320–460 Vac AC Frequency: 45/65Hz Supported networks: single-phase and three-phase, L/N/PE; L1 / L2 / L3 / N / PE Maximum Power Consumption: 3W CT Inputs: 333 mV COMMUNICATION Supported Communication Interfaces: RS485 half-duplex, 3-wire (A, B, GND) Response time: ≤ 200 ms Default Device ID (Modbus): 2 RS485 line termination resistance: 120 Ω ACCURACY (at 25 °C, power factor = 1) Accuracy 1% – 100% of CT current rating: ±1.0 % IEC accuracy class: IEC 62053-21 Class 1, IEC 62053-23 Class 2 STANDARDS COMPLIANCE Safety: IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 Immunity: EN 61326-2-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 Emissions: EN 55022 Class B INSTALLATION SPECIFICATIONS Dimension ...
used
GENERAL DATA Cell Type: 120 N-type monocrystalline half-cut cells, 6 strings of 20 cells in series Glass: 3.2mm solar glass with anti-reflective surface treatment Backsheet: High Strength Polymer Construction (Black) Frame: Black anodized aluminum Junction box: 3 parts, 3 by-pass diodes, IP68 rating according to IEC 62790 Cables: 12 AWG (4 mm²) PV cable, length 1.1 m (+) / 1.2 m (−), conforming to EN 50618 Connectors: Stäubli MC4 PV-KBT4 / KST4, 12 AWG (4 mm²), IEC 62852 compliant, IP68 when connected Origin: Made in Singapore MECHANICAL DATA Dimensions: 1755 × 1040 × 30 mm Area: 1.83 m² Weight: 20.0 kg ELECTRICAL DATA – STC CONDITIONS Rated Power (Pmax): 370W Power class (sorting): 0 / +5 W Voltage at maximum power (Vmp): 34.7 V Current at maximum power (Imp): 10.68 A Open Circuit Voltage (Voc): 41.1 V Short Circuit Current (Isc): 11.41 A Module efficiency: ...
used
Model: REC375TP4 GENERAL DATA Cells: 120 P-type monocrystalline half-cut cells, 6 strings of 20 cells in series Glass: 3.2mm solar glass with anti-reflective surface treatment and low iron content Backsheet: high-strength polymer construction Frame: Black anodized aluminum with hook support bars Junction box: 3 parts, 3 by-pass diodes, IP68 rating Connectors: Stäubli MC4-PV-KBT4 / KST4-4mm², IEC 62852 compliant, IP68 when mated Cables: 4 mm² solar cable, 1.2 m length Dimensions: 1755 × 1040 × 30 mm (68.3\" × 40.9\" × 1.18\") Weight: 20.0 kg Origin: Made in Singapore ELECTRICAL DATA – STC CONDITIONS Pmax Rated Power: 375W Classification tolerance: 0 / +5 W Vmp Rated Voltage: 35.0V Imp Current Rating: 10.72A Open Circuit Voltage Voc: 41.3V Isc Short Circuit Current: 11.46A Module efficiency: 20.5 % ELECTRICAL DATA – NMOT CONDITIONS Pmax Rated Power: 283W Vmp Ra ...
used
Detailed manual attached Model: LG AC09BK UA3 Alternative model: S3UM09JARMA Type: Split room air conditioner / split air conditioner Power supply: Single-phase Voltage rating: 220–240 V~ Frequency: 50 Hz CAPACITY Cooling: 2 500 W (8 151 kcal/h) Heating: 3 300 W (2 839 kcal/h) BTU Capacity/hr: 8 538 BTU/hr (cooled) / 11 288 BTU/hr (heated) NOMINAL CONSUMPTION Cooling power consumption: 656 W Heating power consumption: 800 W Cooling current consumption: 3.30 A Heating current consumption: 4.00 A MAXIMUM CONSUMPTION Maximum cooling power consumption: 1 400 W Maximum heating power consumption: 1 600 W Maximum cooling current consumption: 6.00 A Maximum heating current consumption: 7.00 A MAXIMUM PRESSURES High pressure: 4.2 MPa Low pressure: 2.4 MPa REFRIGERANT Type: R32 Quantity: 0.70 kg CO₂ equivalent: 0.473 t OTHER INFORMATION Degree of protection: ...
used
Model: REC370NP2 GENERAL DATA Cells: 120 N-type monocrystalline half-cut cells, 6 strings of 20 cells in series Glass: 3.2mm solar glass with anti-reflective surface treatment Backsheet: high-strength polymer construction Frame: Black anodized aluminum Junction box: 3 parts, 3 by-pass diodes, IP68 according to IEC 62790 Cables: 4 mm² solar cable, length 1.1 m (+) / 1.2 m (−), conforms to EN 50618 Connectors: Stäubli MC4 PV-KBT4 / KST4 (4 mm²), IEC 62852 compliant, IP68 when connected Origin: Made in Singapore MECHANICAL DATA Dimensions: 1755 × 1040 × 30 mm Area: 1.83 m² Weight: 20.0 kg ELECTRICAL DATA – STC Rated power Pmax: 370 W Classification tolerance: 0 / +5 W Voltage at maximum power Vmp: 34.7 V Current at maximum power Imp: 10.68 A Open circuit voltage Voc: 41.1 V Isc Short Circuit Current: 11.41 A Module efficiency: 20.3 % OPERATING LIMITS Operat ...
used
Detailed manual attached Including 10 pieces DANFOSS ALLY Radiator Thermostat Single piece loading dimensions: 850 x 530 x 300 mm Auction-ID: A7-47781-351
used
Single piece loading dimensions: 2200 x 100 x 100 mm Cross-section: 60 x 35 mm Length: 2100 mm Auction-ID: A7-47536-457
used
Detailed manual attached Loading dimensions: 400 x 250 x 100 mm Auction-ID: A7-47536-541
used
Single piece loading dimensions: 400 x 600 x 200 mm (box 50 pcs) Auction-ID: A7-47536-505
used
Model: SolarEdge P801 INPUT (DC) Rated DC Input Power: 800W Absolute maximum input voltage (Voc at lowest temperature): 125 Vdc MPPT Operating Range: 12.5 – 105 Vdc Maximum Short Circuit Current (Isc): 11.75 A Maximum efficiency: 99.5 % Weighted efficiency: 98.6 % Overvoltage category: II OUTPUT DURING OPERATION Maximum Output Current: 15 Adc Maximum output voltage: 80 Vdc EXIT DURING STAND-BY Safety output voltage for power optimizer: 1 ± 0.1 Vdc STANDARDS COMPLIANCE Electromagnetic compatibility: FCC Part 15, IEC 61000-6-2, IEC 61000-6-3 Class B, EN 55011 Class A Safety: IEC 62109-1 (Safety Class II) RoHS compliant: Yes Fire safety: VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Compatible SolarEdge inverters: SE16K and above three-phase inverters Maximum permissible voltage of the system: 1000 Vdc Dimensions (W × D × H): 129 × 153 × 49.5 mm Weigh ...
used
GENERAL DATA Cell Type: 120 N-type monocrystalline half-cut cells, 6 strings of 20 cells in series Glass: 3.2mm solar glass with anti-reflective surface treatment Backsheet: High Strength Polymer Construction (Black) Frame: Black anodized aluminum Junction box: 3 parts, 3 by-pass diodes, IP68 rating according to IEC 62790 Cables: 12 AWG (4 mm²) PV cable, length 1.1 m (+) / 1.2 m (−), conforming to EN 50618 Connectors: Stäubli MC4 PV-KBT4 / KST4, 12 AWG (4 mm²), IEC 62852 compliant, IP68 when connected Origin: Made in Singapore MECHANICAL DATA Dimensions: 1755 × 1040 × 30 mm Area: 1.83 m² Weight: 20.0 kg ELECTRICAL DATA – STC CONDITIONS Rated Power (Pmax): 370W Power class (sorting): 0 / +5 W Voltage at maximum power (Vmp): 34.7 V Current at maximum power (Imp): 10.68 A Open Circuit Voltage (Voc): 41.1 V Short Circuit Current (Isc): 11.41 A Module efficiency: ...
used
Composed of: - Model Compress 7000i AW 13s - MS - Puffer PS 100 model with 103 liter capacity - CR10 - Modulating thermostat - VW1 - 3-way diverter valve (mod LK525) for external DHW tank load - TWM20 DN20 thermostatic mixer for drinking water - AAS1 kit for connecting the solar circuit with the expansion tank - 1FT/ST/B kit with 1 FT 226-2V solar collector - FKA 26 mounting kit - AGS10 MS100-2 dual-line model - SAG 25 expansion tank - Tank of heat transfer liquid Tyfocor® L WTF20 - Twin-Tube 15-10 Cu - Flexible outdoor unit connection kit to piping Loading Dimensions: Pallet 1:1100x1200x2000mm Pallet 2: 800x1200x2350 mm Pallet 3: 800x800x2100 mm Pallet 4: 1200x800x1500 mm Auction-ID: A7-47781-147
used
Single workpiece loading dimensions: 280 x280x200 mm Auction-ID: A7-47536-450
used
Single piece loading dimensions: 200 x 240 x 120 mm Auction-ID: A7-47536-171
used
Single piece loading dimensions: 2200 x 100 x 100 mm Cross-section: 60 x 35 mm Length: 2100 mm Auction-ID: A7-47536-556
used
Detailed manual attached Loading dimensions: 500x300x300 mm Auction-ID: A7-47536-130
used
Detailed manual attached Single piece loading dimensions: 600 x 580 x 1550 mm Auction-ID: A7-47781-369
used
Model: JAM60S21-370/MR MECHANICAL SPECIFICATIONS Cell Type: Mono Weight: 20.2 kg Dimensions: 1769 × 1052 × 30 mm Cable cross-section: 4 mm² (IEC), 12 AWG (UL) Number of cells: 120 (6 × 20) Junction box: IP68, 3 diodes Connector: MC4-EVO2 / QC 4.10-35 Cable length (including connector): – Vertical: 400 mm (+) / 300 mm (-) – Horizontal: 1000 mm (+) / 1000 mm (-) Packing configuration: 36pcs/pallet, 936pcs/40HQ ELECTRICAL PARAMETERS AT STC Maximum Power (Pmax): 370 W Open Circuit Voltage (Voc): 41.30 V Voltage at maximum power (Vmp): 34.23 V Short Circuit Current (Isc): 11.35 A Current at maximum power (Imp): 10.81 A Module Efficiency: 19.9 % Power tolerance: 0 ~ +5 W TEMPERATURE COEFFICIENTS Isc coefficient: +0.044 %/°C Voc coefficient: −0.272 %/°C Pmax coefficient: −0.350 %/°C STC CONDITIONS Irradiance: 1000 W/m² Cell temperature: 25 °C Spect ...
used
Detailed manual attached Single piece loading dimensions: 1050 x 360 x 300 mm Auction-ID: A7-47779-213
used
Loading dimensions: 150 x 150 x 100 mm Auction-ID: A7-47781-117
used
Detailed manual attached Single piece loading dimensions: 1050 x 360 x 300 mm Auction-ID: A7-47779-210
used
Single piece loading dimensions: 1900 x 35 x 3 mm Auction-ID: A7-47536-467
used
Single piece loading dimensions: 200x170x150 mm Auction-ID: A7-47536-166
used
Detailed manual attached Model: LG AC09BK UA3 Alternative model: S3UM09JARMA Type: Split room air conditioner / split air conditioner Power supply: Single-phase Voltage rating: 220–240 V~ Frequency: 50 Hz CAPACITY Cooling: 2 500 W (8 151 kcal/h) Heating: 3 300 W (2 839 kcal/h) BTU Capacity/hr: 8 538 BTU/hr (cooled) / 11 288 BTU/hr (heated) NOMINAL CONSUMPTION Cooling power consumption: 656 W Heating power consumption: 800 W Cooling current consumption: 3.30 A Heating current consumption: 4.00 A MAXIMUM CONSUMPTION Maximum cooling power consumption: 1 400 W Maximum heating power consumption: 1 600 W Maximum cooling current consumption: 6.00 A Maximum heating current consumption: 7.00 A MAXIMUM PRESSURES High pressure: 4.2 MPa Low pressure: 2.4 MPa REFRIGERANT Type: R32 Quantity: 0.70 kg CO₂ equivalent: 0.473 t OTHER INFORMATION Degree of protection: ...
used
AC/DC switchboard without disconnector. 1 string, ability to handle 1 MPPT. Single piece loading dimensions: 500 x 350 x 200 mm Auction-ID: A7-47536-18
used
Detailed manual attached Loading dimensions: 400 x 250 x 100 mm Auction-ID: A7-47536-540
used
2 strings / 2 600V outputs with double disconnector Single piece loading dimensions: 500 x 350 x 200 mm Auction-ID: A7-47536-560
used
Working dimensions: 4,400 x 1,300 mm Features: - Overhead tool changer - Drilling, milling and grooving functions Voltage: 380 V Transport: 1 full truck required (6,000 kg) Auction-ID: A1-47766-413
used
Detailed manual attached Loading dimensions: 580x580x1280 mm Auction-ID: A7-47781-371
used
Single piece loading dimensions: 200x170x150 mm Auction-ID: A7-47536-165
used
Single piece loading dimensions: 1900 x 35 x 3 mm Auction-ID: A7-47536-465
used
Manual detailed in description Single workpiece loading dimensions: 550 x 600 x 1500 mm Auction-ID: A7-47781-392
used
Detailed manual attached Single piece loading dimensions: 830 x 320 x 550 mm Auction-ID: A7-47779-100
used
Detailed manual attached Indoor Unit Model: AP12RT NSJ Model Code: S3NM12JA1YB Phase / Power supply: Single phase Voltage rating: 220–240 V~ Frequency: 50 Hz Maximum Current (Internal): 0.2A Maximum Pressure (High): 4.2 MPa Maximum Pressure (Low): 2.4 MPa Refrigerant: R410A or R32 Refrigerant Quantity: (Not indicated on the label provided) Degree of protection: IPX4 Markings/notes: CE, information symbols; Contains fluorinated gases Loading dimensions: 900 x 400 x 250 mm Auction-ID: A7-47779-107
used
Three-phase AC/DC switchboard with disconnector. 2 string, possibility to manage 2 MPPTs. Single piece loading dimensions: 640 x 320 x 200 mm Auction-ID: A7-47536-182
used
Detailed manual attached Single piece loading dimensions: 640 x 840 x 300 mm Auction-ID: A7-47779-174
used
Single piece loading dimensions: 400 x 400 x 320 mm Auction-ID: A7-47536-332
used
Single piece loading dimensions: 2200 x 100 x 100 mm Cross-section: 60 x 35 mm Length: 2100 mm Auction-ID: A7-47536-462
used
Three-phase AC/DC switchboard with disconnector. 2 string, possibility to manage 2 MPPTs. Single piece loading dimensions: 640 x 320 x 200 mm Auction-ID: A7-47536-181
used
Composed of: - Model CSH7000iAW 7 OR - BPU300 model with 202 l ACS and 78 l inertial capacity - CR10 - Modulating thermostat - VW1 - 3-way diverter valve (mod LK525) for external DHW tank load - TWM20 DN20 thermostatic mixer for drinking water - Vertical adapter 80/125 to 60/100 mm - Vertical adapter 80/125 to 60/100 mm - Flexible outdoor unit connection kit to piping - 3/4\" magnetic filter required for CSH7000iAW - SF3 - NTC temperature probe for DHW boilers - Model GC7000i W 14 with 14 kW in heating Load measurements: Pallet 1: 1200x900x1850 mm Pallet 2: 1200x800x1300 mm Pallet 3: 700x700x2000 mm Auction-ID: A7-47781-6
used
Single piece loading dimensions: 2200 x 100 x 100 mm Cross-section: 60 x 35 mm Length: 2100 mm Auction-ID: A7-47536-452