Machine: MTA TAEevo Tech 902 P3
New in: 2020
used

Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 902 P3 MTA S.p.A. TAEevo Tech 902 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 178 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 30.4 Available pump pressure (bar) 3.16 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 90 Max. current (A) 160 Star ...

approved
dealer
Machine: MTA TAEevo Tech 1002 P3
New in: 2022
used

Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...

approved
dealer
Machine: MTA TAEevo Tech 1002 P3
New in: 2022
used

Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...

approved
dealer
Machine: MTA TAEevo Tech 902 P3
New in: 2020
used

Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 902 P3 MTA S.p.A. TAEevo Tech 902 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 178 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 30.4 Available pump pressure (bar) 3.16 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 90 Max. current (A) 160 Star ...

approved
dealer
Machine: MTA HCY 051
New in: 2021
used

Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...

approved
dealer
Machine: MTA HCY 051
New in: 2021
used

Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...

Machine: MTA TAE EVO 051
used
Seller: Land-pl ChillerTech
Location:: 03-55 Warszawa

Water chiller chiller MTA TAE EVO 051 with cooling capacity 20 kW | ChillerTech - Sale and rental of water chillers Technical Specification: -Manufacturer: MTA -Cooling capacity: 20.4 kW -Model: TAE EVO 051 -Year of manufacture: - -Refrigerant: R407C -Dimensions: length – ... Mm; width–... Mm; height–... Mm -Notes: no front cover / does not affect the operation of the device Device available immediately Check out our other cooling/heating equipment...

approved
dealer
Machine: MTA OCEAN Tech OCT-H 150
New in: 2019
new

Heat pump or chiller, water-cooled, Type: OCEAN Tech OCT-H 150, M.T.A. S.p.A. OCEAN Tech OCT-H 150 are heat pumps (alternatively chiller) water / water for indoor installation without hydraulic circuit (pump, accumulator) incl. crankcase heating, phase monitoring. (The dry cooler, storage tank and pumps are not included in the offer). Heating capacity 50.2 Capacitor Hot water temp. Outlet / Entrance: 45 / 40°C Volume flow m³/h 6.33 Evaporator Medium: Hot water Cooling water temp. Outlet/ Entrance: 7 / 12°C Medium: Cold water Refrigerant R 410A (Cooling capacity 44.6 – optionally possible) Evaporator Cold water temp. Outlet/ Entrance: 7 / 12°C Volume flow m³/h  ...

approved
dealer
Machine: MTA OCEAN Tech OCT-H 150
New in: 2019
new

Heat pump or chiller, water-cooled, Type: OCEAN Tech OCT-H 150, M.T.A. S.p.A. OCEAN Tech OCT-H 150 are heat pumps (alternatively chiller) water / water for indoor installation without hydraulic circuit (pump, accumulator) incl. crankcase heating, phase monitoring. (The dry cooler, storage tank and pumps are not included in the offer). Heating capacity 50.2 Capacitor Hot water temp. Outlet / Entrance: 45 / 40°C Volume flow m³/h 6.33 Evaporator Medium: Hot water Cooling water temp. Outlet/ Entrance: 7 / 12°C Medium: Cold water Refrigerant R 410A (Cooling capacity 44.6 – optionally possible) Evaporator Cold water temp. Outlet/ Entrance: 7 / 12°C Volume flow m³/h  ...

approved
dealer
Machine: MTA Galaxy TECH GLT330HE_Special
New in: 2020
used

Process air chiller / chiller / chiller - air cooled, Type: Galaxy TECH GLT330HE_Special M.T.A. S.p.A. The Galaxy GLT 330 HE-special are compact chillers suitable for outdoor installation (from -20°C to +40°C) and for cold water temperatures down to -10°C. Equipped with: - shell and tube evaporators, - scroll compressors, - control cabinet, - shut-off valves for compressors, - Equipment for low ambient temperatures down to -20°C, - P3 pump, - 510 litres buffer tank, - compressor housing, -Vibration damper - Vitaulic couplings. Cooling capacity (kW): 900 Cold water temp. Exit/ Entry (°C): 7 / 12 Volume flow (m³/h): 171 Available pump pressure bar: 2,22  ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)