item-No.: 159829736 is deleted from the database!

10 similar machines:

approved
dealer
Machine: MTA Chiller
used
Seller: Land-uk Andrew Isaacs Machinery International Ltd
VS

Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg  ...

  • more information

approved
dealer
Machine: MTA iHCY 171 PT1+FSH - 45/41 kW
used

Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 171 PT1+FSH Heat pumps, MTA S.p.A. HCYGNUS TECH Inverter iHCY 171 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C suction temperature. Including crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 45.9 Heating water temp. Exit/inlet: 45 / 40°C Volume flow m³/h 7.96 Available pump pressure bar: 0.36 Ambient temperature °C +7 Cooling capacity kW 41.5 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 7.07  ...

date: 02.09.2024 item-No.: 164897335
approved
dealer
Machine: MTA iHCY 171 PT1+FSH - 45/41 kW
New in: 2022
used

Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 171 PT1+FSH Heat pumps, MTA S.p.A. HCYGNUS TECH Inverter iHCY 171 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C suction temperature. Including crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 45.9 Heating water temp. Exit/inlet: 45 / 40°C Volume flow m³/h 7.96 Available pump pressure bar: 0.36 Ambient temperature °C +7 Cooling capacity kW 41.5 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 7.07  ...

approved
dealer
Machine: MTA Taurus TECH HTAT 040 HE
New in: 2022
new

Heat pump / chiller air-cooled, Type: Taurus TECH HTAT 040 HE MTA S.p.A. Heat pump / chiller Taurus TECH HTAT 040 HE (reversible) with hydronic kit, storage tank + pump P15 + fairing hydraulics. Heating capacity kW 99.3 Cold water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 17.2 Available pump pressure bar 0.966 Ambient temperature +7 °C Cooling capacity kW 84.5 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 14.4 Available pump pressure bar 1.24 Ambient temperature 32 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 47 Max. current (A) 79 Starting current circuit (A) 263 Protection class: IP ...

approved
dealer
Machine: MTA OCEAN Tech HOCT 200
New in: 2022
new

Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400,  ...

approved
dealer
Machine: MTA OCEAN Tech HOCT 200
New in: 2022
new

Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400,  ...

approved
dealer
Machine: MTA Aries TECH AST 100 SHE – 21
New in: 2019
used

Process chiller / chiller air-cooled, Type: - Aries TECH AST 100 SHE – 215 kW Refrigeration Machines, MTA S.p.A. The Aries TECH AST 100 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, 400 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 215 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 36.9 Available. Pump pressure (bar): 2.6 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quanti ...

approved
dealer
Machine: MTA TAEevo Tech 602 P3 - 116 kW
New in: 2022
used

Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Ci ...

approved
dealer
Machine: MTA TAEevo Tech 121 P5 - 35 kW
used

Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 121 P5 Refrigeration Machines, MTA S.p.A. TAEevo Tech 121 P5 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P5 high-pressure circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 35 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.92 Available pump pressure (bar) 4.74 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 20 Max ...

approved
dealer
Machine: MTA TWEevo Tech 381 P3
New in: 2021
used

Process water chiller / chiller / chiller water cooled, Type: TWEevo Tech 381 P3 MTA S.p.A. TWEevo Tech 381 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 72.2 [20.5 tons cooling] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 12.3 Available pump pressure (bar) 3.46 Cooling water temp. Outlet/Entry (°C): 45 / 40 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 39  ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)