We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Labeller STS | 2015 Adhesive: 2015 Speed: 1.200 bph Direction: linear (from sx to dx) 4 adhesive stations Labeller: Front, rear, collar e seal) Safety Protections. ...
labeller STS | S2T3/R Year: 2011 Speed: 2.000 bph Direction: Clockwise 3 heads 3 adhesive stations Capsuler | PVC Plateau capsules distribution Printing machine thermic transfer Safety protections ...
ROTARY TABLE MILLING MACHINE Condition Used Very good condition Control type Selca S4040-D Table length 1.600 mm Table width 1.200 mm X axis stroke 2.500 mm Y-axis stroke 1.700 mm Z axis stroke 1.500 mm Rapid 40 mt/min Rotational speed 4,000 rpm Spindle power 17 Kw Internal diameter front bearing. Ø 90 mm Oil spindle bearing lubrication Oil spindle line cooling, closed circuit with air conditioner
Used Bottle Labeler STS S2T6 R year 2009 Labeling machine made in 2009 in practically new condition with clockwise rotation and 4 stations Various types of labeling including adhesive hot glue cold glue roll feed self adhesive reel Two labels ready and two labels on the back The total weight of the machine is 700 kg It works with 380 volts of power and 50 Hz [...for more information send your inquiry to the seller.] refno: ET131
Francis turbine, used 40 kW, 3 m³, height 2m Speed 106 / 375 RPM 69 HP, built in 1963 Generator Schorch GmbH Type KT 7315 s FB01 Z-Z 50 Hz, 512U/min 55kW ...
Kaplan turbine used 50 kW, 3 m³, height 2m Speed 150 / 460 RPM 70 HP, built in 1963 Generator Schorch GmbH Type KT7280S - DB05 Z-Z 50 Hz, 770 RPM 55kW ...
HHI-BBC Turbine Housing RPM - 17400 Only the turbine hull. ...
Condensing Steam Turbine Peter Brotherhood Ltd. (England) Power Output – 3500 kW Normal Running Speed – 7035 RPM Trip Speed – 7739/8090 RPM Steam Inlet Pressure – 40 bar G Steam Inlet Temperature – 480° C Exhaust Pressure - 0.10 bar A ...
Qty. 1 Second-hand power plant including boiler (BFB – boiler: bubbling fluidized bed) Mfc.: Foster Wheeler, Siemens, Raumaster, YIT Corporation, Honeywell, Built: 2001, 2002, 2006, 2009 Revision: 2009 Insulation removed in 2018 BFB Boiler – 88 MW Steam turbine – 22.5 MW Main Steam Cycle BFB boiler K7 – Some parts removed and storaged indoor at the paper mill area – Boiler is made electrically safe (cables cut) – Dry conservation ongoing since 2014 (tubes filled with nitrogen, dry air circulation) – Steam Turbine VP4 (in storage) Generator (in storage) Power Plant – Function Primary function is to produce steam for the Paper Mill reliable and economically S ...
Biomass Plant, 5 MWel, 50 Hz, yoc 2002, in operation Boiler • Technical data: - Fuel tank capacity: approx. 1 .300 m 3 - Exhaust gas volume 29,000 Nm3/h - Average combustion temperature of 900°C (850 for 2 s.) - Thermal power of the furnace 13 MW - 2 add. Burners 5 MW each - Average calorific value Hu 12,500 kJ/kg - Throughput capacity 3,991 kg/h - Boiler working pressure 41 bar - Superheated steam temperature 420°C - designed amount of steam 14 t/h - Fuels: RDF, wood chips, straw, remains of chipboard, choiceed waste Hours of operation of the entire plant appr. 120,000 hours Steam turbine - TWIN steam turbine KKK, type: CFR 3 / AFA 6 GTA ...