General SKU300U589 LocationBarneveld MakeKorsch TypeEK 0 No.K0000094 Year of construction2001 Main Features Tablet Diameter20 mm Specified Features - Single stroke tablet press MaterialStainless steel 1.4301 (304), Stainless steel 1.4435 (316L), Tool steel 1.2721 Single stroke tablet presscheck Tablet diametermax. 20 mm Filling depth0-20 mm Die diameter20 mm With filling shoecheck With hoppercheck Capacitymax. 3600 st. With motor0,55 kW, 220/380Volt With variable speed drive10-60 rpm Information Mounted on frameStainless steel cabinet With switchcheck With switchgearcheck Weight180 kg CEcheck Floorspace0,74x0,46 m Total height1,90m Extra Specifications- with vari ...
General SKU300U588 LocationBarneveld MakeKorsch TypeXL 100-8-EUD No.K1510018 Year of construction2001 Main Features Tablet Diameter25 mm Material Specified Features - Rotating tablet press Rotating tablet presscheck Number of stations:1 With punching dies8-10-12 With key on punching diescheck Tablet sizes13-16-25 mm Filling depth0-6/6 mm: 4-10/10 mm: 10-16/16 mm With motorcheck (2,2kW, 220-240/380-415 Volt, 1400 rpm) With frequency controllercheck (20-120, 20-120, 20-60 rpm) Capacity29.000-72.000-86.400 pc/h With hoppercheck Information Mounted on framecheck With switchcheck With switchgearcheck Weight960 kg CEcheck Floorspace1,6x0,7 m Total height2 mRotating tab ...
Korsch EK III single station eccentric tablet press, maximum tablet diameter 60mm, maximum depth of fill 70mm (currently set for maximum 30mm depth of fill). Maximum pressure 200kN. Four speed (11, 22, 32, 42 strokes/minute) capacity up to 2520 tablets per hour, using a single-tip tool. ...
Used tablet press made by KORSCH, model PH 343. New 1977. ...
Used tablet press made by KORSCH Pharmapress 300 series. Model PH 343. Tablet diameter 6-13mm. 43 stations. 4 pieces available (2 x 1984, 1 x 1989, 1 x 1990) ...
• Single rotary press with 47 punch stations • Tool type EU 19 with BBS dies (die diam. 22 mm) • Unkeyed turret • Output 28,200 - 282,000 sheets/hour • Pressing force max. 80 kN, pre-pressing force max. 20 kN • Tablet-diam. max. 13 mm • Tablet height max. 8.5 mm • Filling depth max. 18 mm depending on filling curve (filling curve 10 mm fitted) • Filling hopper with flange for docking Bohle container MCG500/900 for powder feeding • Agitator blade filling shoe (Fill-o-matic) for fine powder materials (1 spare filling shoe available) • Fast diverter for missing tablets • Korsch PHK2i Plus press force control system • Touch screen Siemens, software operating ...
Korsch EK II single station eccentric tablet press, maximum tablet diameter 50 mm, maximum depth of fill 40 mm, Maximum pressure 120 kN. capacity up to 3600 tablets per hour using a single-tip tooling, machine net weight approx. 600 kg ...
Korsch Pharmakontroll PHK 2/171 kN machine monitoring and control system for rotary tablet presses. ...
Copley tablet testing complete lab suite, supplied new in 2018 and in as new condition, complete with manufacturers manuals. Comprising of the following items of equipment. Dissolution 8000. 8 bath dissolution with printer DissoMate Degasser station DTG 4000. 4 bath dissintegration with printer FRV 2000. 2 wheel friability, variable speed TBF 1000. Tablet hardness tester with keyboard input and printer
General SKU300U1188 LocationBarneveld MakePharma test TypeWHT-SM / WHT-2ME Mach.No.10459 / 10452 Specified Features - Miscellaneous Capacity2 testing stations Motor220 volt Capacity10 to 15 tests/min Information Year of construction2001 Total height0,51 m CEcheck Floor space1,0x0,9 m Weight105 kg Extra SpecificationsMulti batch Tablet hardness tester with multi batch feeder. hardness test range 5.0-500.0 N, thickness testing range 1.00-20.00mm, diameter testing range 2.00-30.00 mm, weight testing range 0.0001-200.0000g MiscellaneousPharma TestMiscellaneous > MiscellaneousBrand > Pharma Test What you can expect from Foeth: -- Machine is in working condition -- At a reduced pr ...