Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...
Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 131 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 131 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C intake temperature. Includes crankcase heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 35.5 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 6.18 Available pump pressure bar: 0.644 Ambient temperature °C +7 Cooling capacity kW 31.8 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 5.41 Avai ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 131 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 131 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C intake temperature. Includes crankcase heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 35.5 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 6.18 Available pump pressure bar: 0.644 Ambient temperature °C +7 Cooling capacity kW 31.8 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 5.41 Avai ...
Process air chiller / chiller / chiller - air cooled, Type: Galaxy TECH GLT330HE_Special M.T.A. S.p.A. The Galaxy GLT 330 HE-special are compact chillers suitable for outdoor installation (from -20°C to +40°C) and for cold water temperatures down to -10°C. Equipped with: - shell and tube evaporators, - scroll compressors, - control cabinet, - shut-off valves for compressors, - Equipment for low ambient temperatures down to -20°C, - P3 pump, - 510 litres buffer tank, - compressor housing, -Vibration damper - Vitaulic couplings. Cooling capacity (kW): 900 Cold water temp. Exit/ Entry (°C): 7 / 12 Volume flow (m³/h): 171 Available pump pressure bar: 2,22 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, buffer tank 678 ltr. and built-in P3 circulating pump. Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,5 Max. current (A) 119.3 Starting current circuit (A) 235 Protection Class: IP54 Dimensions: Length (m ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 351P3-20 MTA S.p.A. TAEevo Tech 351P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, electronic expansion valves, phase monitoring, buffer tank 350 ltr., built-in P3 circulation pump and speed-controlled fans. Cooling capacity kW 66.9 Cold water temp. Exit/Entry (°C): 7 / 12 Medium: Water Volume flow (m³/h) 11.4 Available pump pressure (bar) 3.02 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 37.48 Max. current (A) 64,44 Starting curre ...
Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...
Process water chiller / chiller / chiller water cooled, Type: TWEevo Tech 381 P3 MTA S.p.A. TWEevo Tech 381 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 72.2 [20.5 tons cooling] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 12.3 Available pump pressure (bar) 3.46 Cooling water temp. Outlet/Entry (°C): 45 / 40 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 39 ...
Air cooler / process chiller / chiller air-cooled, Type: TAEevo Tech 251 P3-20 MTA S.p.A. TAEevo Tech 251P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 350 ltr. and built-in P3 Circulating pump. Cooling capacity kW 50.4 Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 8.59 Available pump pressure (bar) 2.61 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 26.99 Max. current (A) 45,79 Starting current circuit (A) 144.38 Protection class: IP54 Dimensions: Le ...