1. Technical details
1.1 Dimensions
Hall area: 253.00 square meters
Length of the hall:
24,298 m AK wall
24.228 m AK Steel
24.00 m center-center end wall supports
Width of the hall:
10.40 m AK wall
10.33 m AK steel
10.00 m center-center frame supports
Eaves height: 5.115 m at the intersection of roof and wall
Ridge height: 6.511 m Building height
Roof pitch: 15 degrees (symmetrical gable roof).
1.2 Load assumptions
Wind load zone: 1.32 kN/m².
Snow load: 0.75 kN/m².
1.3 Structure
The primary construction consists of:
Double-hinged frame with truss spacing of 4.00 m (axial dimension)
Hot-dip galvanized steel hollow sections, placed on anchor plates and
hinged
Purlins and bolts made of galvanized steel profiles, which are hooked
into the frame structure.
1.4 Gable construction
Galvanized gable handles, infilled by wall beams.
Tension strap in the truss construction for static support.
Wind braces made of steel cables in roof and wall planes.
1.5 Foundation
Ground anchors on asphalt surface.
1.6 Roofing
Trapezoidal steel sheet "35/207 N" negative layer with
anti-condensation coating, RAL 9006 (white aluminium), on roof purlins
made of galvanised steel profiles.
1.7 Wall cladding
Trapezoidal steel sheet "35/207 P" positive layer, RAL 9006 (white
aluminium), on wall beams made of galvanised steel profiles.
1.8 Equipment
1 piece aluminium roller shutter (WxH: approx. 3.85 x 4.15 m)
single-walled, electrically operated, in the end wall in axis 7.
2 escape doors (1000 x 2135 mm) in the axes 7 and A, 1-2.
Continuous rooflights (approx. 20 x 0.80 m) made of translucent,
impacting T51226000 trapezoidal profiles on both sides of the eaves.
2. Documentation
PDF copies of the original construction documents, including static
calculations and construction drawings from 2004.
3. Availability
The hall can be dismantled in November/December 2025 immediately after
it has been vacated.
4. Location
Address: Saarbrücken, Saarland.
Viewing by appointment.
4.1 Load assumptions according to construction documents
Snow load: 0.75 kN/m².
Wind load: 0.32 kN/m².
For current load assumptions at your location, please use the Dlubal
online services.
5. Basis for negotiation
The offer is offered against bid AS STANDS, plus dismantling. Subject
to changes, errors and prior sale.