Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...
Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 201P3 MTA S.p.A. TAEevo Tech 201 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 350 ltr. And built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 44.2 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 7.53 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 23.69 Max. current (A) 39,83 Starting c ...
Process Air Cooler / Chiller / Chiller Air Cooled, Type: TAEevo Tech 020 P3 MTA S.p.A. TAEevo Tech 020 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 5,68 [19380 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 0.951 Available pump pressure (bar) 2.9 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 4.12 Max. current (A) 7.21 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 081 P3 MTA S.p.A. TAEevo Tech 081 P3 are air-cooled compact water chillers that are suitable for outdoor installation. Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 Circulating pump. Cooling capacity kW 22.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 3.82 Available pump pressure (bar) 2.69 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 12.04 Max. current (A) 20.2 Starting current circuit (A) 113.37 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) ...
Air cooler / process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 M.T.A. S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr. And built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature 32 °C, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 60.99 Max. current (A) 102,78 S ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic fuel injectors, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 79.48 Max. current (A) 142.2 Starting current circuit (A) 286.2 Protection class ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 902 P3 MTA S.p.A. TAEevo Tech 902 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 178 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 30.4 Available pump pressure (bar) 3.16 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 90 Max. current (A) 160 Star ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, electronic injectors, buffer tank 678 ltr. and built-in P3 circulating pump: Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,48 Max. current (A) 119.28 Starting current circuit (A) 235,01 Protection Class: IP5 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, buffer tank 678 ltr. and built-in P3 circulating pump. Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,5 Max. current (A) 119.3 Starting current circuit (A) 235 Protection Class: IP54 Dimensions: Length (m ...