X-Ray System PRECISION X-RAY X-Rad 160 XL

электрические части / электрические части

Производитель: PRECISION X-RAY

Модель:X-Rad 160 XL

Тип техники: X-Ray System

Номер позиции: 170072365

Количество: 1

Дата: 20.08.2026

Год выпуска: 2024

Местоположение: Dallas, TX

Цена:


Seller-item-No.:9413443

Manufacturer: Precision X-Ray

Model: X-Rad 160 XL

Year of Manufacture: 2024

Run time: Approximately 80 hours, based on unit logs

Machine type: X-ray irradiation system

Input voltage: 1PH 230VAC, 50/60Hz

FLA (Full Load Amps): 40 Amp

Application: Used to irradiate semiconductor ICs for robustness testing to X-ray exposure Usage history: The project this unit was purchased for has concluded. It was found the exposure type could not be well quantified for future qualification needs, so the unit has not been used much recently.

Condition: Fully functional, but displays error messages that do not clear during warm-up or irradiation. When this occurs the unit must be restarted, and it may take several attempts to complete warm-up and function.

Cooling: The tube cooler is wall-mounted to save space, but can also be set on the floor.Hoses allow the unit to be positioned at least 10 feet from the main cabinet, and can be extended further as needed

Mounting bracket: A repurposed HVAC bracket is included in the purchase

Find more here - .ucymachines/

Contact us at - sales@ucymachines
Поделитесь этой машиной на Facebook:

Запрос

Вы продавец техники?

Пожалуйста выберети

Отправить запрос?

Копия к вам?

Save input data

Manufacturer: Precision X-Ray

Model: X-Rad 160 XL

Year of Manufacture: 2024

Run time: Approximately 80 hours, based on unit logs

Machine type: X-ray irradiation system

Input voltage: 1PH 230VAC, 50/60Hz

FLA (Full Load Amps): 40 Amp

Application: Used to irradiate semiconductor ICs for robustness testing to X-ray exposure Usage history: The project this unit was purchased for has concluded. It was found the exposure type could not be well quantified for future qualification needs, so the unit has not been used much recently.

Condition: Fully functional, but displays error messages that do not clear during warm-up or irradiation. When this occurs the unit must be restarted, and it may take several attempts to complete warm-up and function.

Cooling: The tube cooler is wall-mounted to save space, but can also be set on the floor.Hoses allow the unit to be positioned at least 10 feet from the main cabinet, and can be extended further as needed

Mounting bracket: A repurposed HVAC bracket is included in the purchase

Find more here - .ucymachines/

Contact us at - sales@ucymachines
seller offer No. resale 9413443
Поделитесь этой машиной на Facebook:

Продавец

logo dealer

UCY Industrial GmbH

господи́н Nick Breinfalk
82049 Pullach
Germany

RESALE член с 2024

  • список машин (1268)

Запрос

Вы продавец техники?

Пожалуйста выберети

Отправить запрос?

(всем дилерам с такой машиной)

Копия к вам?

(копия вашего запроса будет отправлена на ваш адрес эл. почты)

Save input data

(Save input data for further inquiries)