X-Ray System PRECISION X-RAY X-Rad 160 XL

електричні частини / електричні частини

Виробник: PRECISION X-RAY

Модель:X-Rad 160 XL

Тип техніки: X-Ray System

Номер позиції: 170072365

Кількість: 1

Дата: 20.08.2026

Рік випуску: 2024

Місцезнаходження: Dallas, TX

Ціна:


Seller-item-No.:9413443

Manufacturer: Precision X-Ray

Model: X-Rad 160 XL

Year of Manufacture: 2024

Run time: Approximately 80 hours, based on unit logs

Machine type: X-ray irradiation system

Input voltage: 1PH 230VAC, 50/60Hz

FLA (Full Load Amps): 40 Amp

Application: Used to irradiate semiconductor ICs for robustness testing to X-ray exposure Usage history: The project this unit was purchased for has concluded. It was found the exposure type could not be well quantified for future qualification needs, so the unit has not been used much recently.

Condition: Fully functional, but displays error messages that do not clear during warm-up or irradiation. When this occurs the unit must be restarted, and it may take several attempts to complete warm-up and function.

Cooling: The tube cooler is wall-mounted to save space, but can also be set on the floor.Hoses allow the unit to be positioned at least 10 feet from the main cabinet, and can be extended further as needed

Mounting bracket: A repurposed HVAC bracket is included in the purchase

Find more here - .ucymachines/

Contact us at - sales@ucymachines
Розповісти про цю машину на Facebook:

Запит

Ви дилер техніки?

Будь ласка, виберіть опціонально

Відправити запит пошуку?

Копію для вас?

Save input data

Manufacturer: Precision X-Ray

Model: X-Rad 160 XL

Year of Manufacture: 2024

Run time: Approximately 80 hours, based on unit logs

Machine type: X-ray irradiation system

Input voltage: 1PH 230VAC, 50/60Hz

FLA (Full Load Amps): 40 Amp

Application: Used to irradiate semiconductor ICs for robustness testing to X-ray exposure Usage history: The project this unit was purchased for has concluded. It was found the exposure type could not be well quantified for future qualification needs, so the unit has not been used much recently.

Condition: Fully functional, but displays error messages that do not clear during warm-up or irradiation. When this occurs the unit must be restarted, and it may take several attempts to complete warm-up and function.

Cooling: The tube cooler is wall-mounted to save space, but can also be set on the floor.Hoses allow the unit to be positioned at least 10 feet from the main cabinet, and can be extended further as needed

Mounting bracket: A repurposed HVAC bracket is included in the purchase

Find more here - .ucymachines/

Contact us at - sales@ucymachines
seller offer No. resale 9413443
Розповісти про цю машину на Facebook:

Продавець

logo dealer

UCY Industrial GmbH

пан Nick Breinfalk
82049 Pullach
Germany

RESALE член з 2024

  • список машин (1258)

Запит

Ви дилер техніки?

Будь ласка, виберіть опціонально

Відправити запит пошуку?

(всім дилерам для такої машини)

Копію для вас?

(копія вашого запиту буде відправлена на вашу адресу електронної пошти)

Save input data

(Save input data for further inquiries)