Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3 MTA S.p.A. TAEevo Tech 802 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Di ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3 MTA S.p.A. TAEevo Tech 802 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Di ...
Process Air Cooler/Chiller/Chiller Air Cooled, Type: TAEevo Tech 101 P3 – 27.5 kW Refrigeration Machines, MTA S.p.A. TAEevo Tech 101 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 pump. Optional equipment: open AD kit Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 2.54 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consu ...
Process Air Cooler/Chiller/Chiller Air Cooled, Type: TAEevo Tech 101 P3 – 27.5 kW Refrigeration Machines, MTA S.p.A. TAEevo Tech 101 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 pump. Optional equipment: open AD kit Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 2.54 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consu ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 081 P3-20 – 22.5 kW Refrigeration Machines, MTA S.p.A. Chiller, chiller, chiller TAEevo Tech 081 P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 140 ltr. , built-in P3 Circulation pump and winter control (condenser pressure control down to -20°C). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 22.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 3.82 Available pump pressure (bar) 2.69 Ambient temperature (°C) 32, Refrigerant R 410A, Electri ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 081 P3-20 – 22.5 kW Refrigeration Machines, MTA S.p.A. Chiller, chiller, chiller TAEevo Tech 081 P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 140 ltr. , built-in P3 Circulation pump and winter control (condenser pressure control down to -20°C). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 22.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 3.82 Available pump pressure (bar) 2.69 Ambient temperature (°C) 32, Refrigerant R 410A, Electri ...
EURO-PROM Sp. z o.o. 공랭식 칠러/히트펌프 MTA TAEevo TECH 802 159kW/184kW 냉각 용량: 159 kW / 45.21톤 (12/7 — 35C) 난방 용량: 184 kW / 52.32톤 (40/45 —7C) 제조 연도: 2016 옵션: 히트펌프. 유압 모듈. 냉매 회로: 2개. 열교환기: 탱크에 담긴 핀 증발기 응축기: 구리 / 알루미늄 컴프레서: 4대. 코플랜드 ZP182KQE-TFD-477 (스크롤) 냉매 종류: R410a 팬 수: 3대. (주파수 인버터) 유압 모듈: 1개 로와라 PLM112B14S2/355-E, 확장 선박. 크기: 3.54x1.25x2.2 m. 체중: 2500 kg. 근무 시간: 8650/7460시간. 상태: 양
공정 공기 냉각기/냉각기/냉각기, 공냉식, 유형: TAEevo Tech 031 P5-NF MTA S.p.A. TAEevo Tech 031 P5-NF는 실외 설치(-5C에서 +46C)에 적합한 공냉식 소형 냉각기입니다. 크랭크 팬 가열, 위상 모니터링, 버퍼 탱크 115리터, 내장 P5 고압 펌프, 개방형 팽창 탱크 14리터 및 증발기를 NON FERROUS 버전으로 포함합니다. -10C에서 +30C까지 냉수 출구 온도를 조정할 수 있습니다. 냉각 용량 kW 8.98 냉수 온도. 출구/진입(C): 7 / 12 체적 유량(m³/h) 1.5 사용 가능한 펌프 압력(bar) 5 주위 온도(C) 32, 냉매 R 410A, 전기 데이터: 전압 V 400, 주파수 Hz 50, 위 ...
공정 공기 냉각기/냉각기/냉각기, 공냉식, 유형: TAEevo Tech 031 P5-NF MTA S.p.A. TAEevo Tech 031 P5-NF는 실외 설치(-5C에서 +46C)에 적합한 공냉식 소형 냉각기입니다. 크랭크 팬 가열, 위상 모니터링, 버퍼 탱크 115리터, 내장 P5 고압 펌프, 개방형 팽창 탱크 14리터 및 증발기를 NON FERROUS 버전으로 포함합니다. -10C에서 +30C까지 냉수 출구 온도를 조정할 수 있습니다. 냉각 용량 kW 8.98 냉수 온도. 출구/진입(C): 7 / 12 체적 유량(m³/h) 1.5 사용 가능한 펌프 압력(bar) 5 주위 온도(C) 32, 냉매 R 410A, 전기 데이터: 전압 V 400, 주파수 Hz 50, 위 ...
공정, 냉각기, 냉각기, 공랭식, 종류: TAEevo Tech 502 P3 - 105 kW 냉장기, MTA S.p.A. TAEevo Tech 502P3는 야외 설치에 적합한 공랭식 컴팩트 워터 칠러(-5C에서 +46C)입니다. 냉수 온도는 -10도에서 +30도까지 조절 가능합니다. 크랭크 팬 가열, 위상 모니터링, 버퍼 탱크 500리터 포함. 그리고 내장된 P3 순환 펌프가 있습니다. 더 오싹해, 더 쿨한; 라디에이터 냉각 용량 kW 105 찬물 온도. 출입 (C): 7 / 12 부피 유량(m³/h) 17.9 사용 가능한 펌프 압력(바) 3.42 주변 온도(C) 32, 냉매 R 410A, 전기 데이터: 전압 V 400, 주파수 Hz 50, 상상 pH 3, 최대 전 ...