콤바인사이클 가스터빈 발전소 GE Frame 9FA

발전기엔진터빈보일러 / 터빈

We are pleased to present our complete commercial and technical offer for an unused 2 × 750 MW Combined Cycle Gas Turbine (CCGT) Power Plant, based on GE Frame 9FA technology, supplied, installed, but not commissioned. The plant equipment is available as a complete package, including major ...

생산자: GE

모델:Frame 9FA

기계의 유형: 콤바인사이클 가스터빈 발전소

품목 아니오.: 170359147

양: 1

날짜: 22.10.2026

제조 연도: 2012 새 기계

위치: Land-us 미국 06514 Hamden

값:


가격 제안:

We are pleased to present our complete commercial and technical offer for an unused 2 × 750 MW Combined Cycle Gas Turbine (CCGT) Power Plant, based on GE Frame 9FA technology, supplied, installed, but not commissioned.

The plant equipment is available as a complete package, including major equipment, auxiliaries, and Balance of Plant (BOP).

1. Plant Configuration Overview

Total Configuration:
• 2 × GE Frame 9FA Gas Turbines
• 2 × CMI Triple Pressure HRSG
• 1 × GE Steam Turbine
• Combined Cycle Output: ~750 MW per block

Status:
• Installed / partially installed
• Not commissioned
• Units have never been fired or operated

2. Gas Turbine Island

Gas Turbines

• Quantity: 2 Units
• Manufacturer: GE
• Model: Frame 9FA +e DLN2+
• Fuel: Dual Fuel
• Frequency: 50 Hz
• Site Rated Output: 241,000 kW per unit
• Year of Manufacture / Delivery: 2012
• Status: Installed, unused

Gas Turbine Generators

• Manufacturer: GE
• Rated Capacity: 310,725 kVA

Gas Turbine Transformers

• Manufacturer: Hyundai
• Type: Oil-filled
• Rating: 335 MVA
• Voltage: 15.75 kV

3. Steam Turbine Island

Steam Turbine

• Quantity: 1 Unit
• Manufacturer: GE
• Model: GE-D11
• Type: Condensing
• Rated Output: 276,040 kW
• Configuration:
– HP: 10 Stages
– IP: 8 Stages
– LP: 2 × 5 Stages
• Status: Unused, packaged and stored at port

Steam Turbine Generator

• Manufacturer: GE
• Rated Capacity: 324,760 kVA

Steam Turbine Transformer

• Manufacturer: Hyundai
• Type: Oil-filled
• Rating: 335 MVA
• Voltage: 15.75 kV

4. Heat Recovery Steam Generators (HRSG)

• Quantity: 2 Units
• Manufacturer: CMI – Belgium
• Type: Triple Pressure, Horizontal, Natural Circulation
• Status: Approx. 90% mechanically constructed

5. Auxiliaries & Balance of Plant (BOP)

A complete auxiliary and BOP scope supplied primarily by Aker Solutions, including:

• Black Start System – Sterling Wilson
• Distributed Control System (DCS)
• GE Mark VIe Control System for GT & ST
• Cooling Towers – Hamon
• Electrical BOP & Switchyard Equipment
• Hyundai Power Transformers
• Fuel Gas Conditioning System
• Pumps (CW, Vertical, Horizontal, ACW Booster)
• Piping, valves, heaters, instrumentation
• Isolated Phase Bus Duct
• HT Switchgear, Control & Relay Panels
• Unit Auxiliary Transformers
• Cabling, cable trays, grounding systems

6. Installation & Storage Status

• Major equipment installed but not commissioned
• HRSG: partially erected (~90%)
• Steam turbine: stored, unused
• Approximately 400 containers of equipment remain stored and not yet installed, including:
– Electrical systems
– Mechanical auxiliaries
– Piping & hardware
– Instruments & control components
– Shelf-life items (batteries, filters, paints, etc.)

7. Warranty Status

• The plant has not been commissioned, therefore:
– Original GE warranty has not been consumed
– GE warranty reactivation is possible
• Subject to payment of an applicable fee, GE can reinstate and warrant the units

8. Commercial Notes

• Available as complete package or by negotiated scope
• Ideal for fast-track deployment
• Significant savings compared to new-build lead times
• Immediate availability subject to agreement

Please let us know your level of interest and preferred next steps.
Upon request, we can provide:

• Detailed equipment lists
• Packing lists & container inventory
• Photos & installation reports
• Commercial terms and pricing

We look forward to your feedback.
페이스 북에서이 컴퓨터를 공유 :

문의

기계 딜러?

선택적으로 송금하십시오.

원하는 문의를 보내시겠습니까?

당신에게 복사?

Save input data

We are pleased to present our complete commercial and technical offer for an unused 2 × 750 MW Combined Cycle Gas Turbine (CCGT) Power Plant, based on GE Frame 9FA technology, supplied, installed, but not commissioned.

The plant equipment is available as a complete package, including major equipment, auxiliaries, and Balance of Plant (BOP).

1. Plant Configuration Overview

Total Configuration:
• 2 × GE Frame 9FA Gas Turbines
• 2 × CMI Triple Pressure HRSG
• 1 × GE Steam Turbine
• Combined Cycle Output: ~750 MW per block

Status:
• Installed / partially installed
• Not commissioned
• Units have never been fired or operated

2. Gas Turbine Island

Gas Turbines

• Quantity: 2 Units
• Manufacturer: GE
• Model: Frame 9FA +e DLN2+
• Fuel: Dual Fuel
• Frequency: 50 Hz
• Site Rated Output: 241,000 kW per unit
• Year of Manufacture / Delivery: 2012
• Status: Installed, unused

Gas Turbine Generators

• Manufacturer: GE
• Rated Capacity: 310,725 kVA

Gas Turbine Transformers

• Manufacturer: Hyundai
• Type: Oil-filled
• Rating: 335 MVA
• Voltage: 15.75 kV

3. Steam Turbine Island

Steam Turbine

• Quantity: 1 Unit
• Manufacturer: GE
• Model: GE-D11
• Type: Condensing
• Rated Output: 276,040 kW
• Configuration:
– HP: 10 Stages
– IP: 8 Stages
– LP: 2 × 5 Stages
• Status: Unused, packaged and stored at port

Steam Turbine Generator

• Manufacturer: GE
• Rated Capacity: 324,760 kVA

Steam Turbine Transformer

• Manufacturer: Hyundai
• Type: Oil-filled
• Rating: 335 MVA
• Voltage: 15.75 kV

4. Heat Recovery Steam Generators (HRSG)

• Quantity: 2 Units
• Manufacturer: CMI – Belgium
• Type: Triple Pressure, Horizontal, Natural Circulation
• Status: Approx. 90% mechanically constructed

5. Auxiliaries & Balance of Plant (BOP)

A complete auxiliary and BOP scope supplied primarily by Aker Solutions, including:

• Black Start System – Sterling Wilson
• Distributed Control System (DCS)
• GE Mark VIe Control System for GT & ST
• Cooling Towers – Hamon
• Electrical BOP & Switchyard Equipment
• Hyundai Power Transformers
• Fuel Gas Conditioning System
• Pumps (CW, Vertical, Horizontal, ACW Booster)
• Piping, valves, heaters, instrumentation
• Isolated Phase Bus Duct
• HT Switchgear, Control & Relay Panels
• Unit Auxiliary Transformers
• Cabling, cable trays, grounding systems

6. Installation & Storage Status

• Major equipment installed but not commissioned
• HRSG: partially erected (~90%)
• Steam turbine: stored, unused
• Approximately 400 containers of equipment remain stored and not yet installed, including:
– Electrical systems
– Mechanical auxiliaries
– Piping & hardware
– Instruments & control components
– Shelf-life items (batteries, filters, paints, etc.)

7. Warranty Status

• The plant has not been commissioned, therefore:
– Original GE warranty has not been consumed
– GE warranty reactivation is possible
• Subject to payment of an applicable fee, GE can reinstate and warrant the units

8. Commercial Notes

• Available as complete package or by negotiated scope
• Ideal for fast-track deployment
• Significant savings compared to new-build lead times
• Immediate availability subject to agreement

Please let us know your level of interest and preferred next steps.
Upon request, we can provide:

• Detailed equipment lists
• Packing lists & container inventory
• Photos & installation reports
• Commercial terms and pricing

We look forward to your feedback.
seller offer No. resale 170359147
페이스 북에서이 컴퓨터를 공유 :
승인
딜러

파는 사람

Evelin of America Corporation

Mr Yury Smirnoff
06514 Hamden
USA

RESALE 구성원 이래 2022

  • 컴퓨터 목록 (100)

문의

기계 딜러?

선택적으로 송금하십시오.

원하는 문의를 보내시겠습니까?

(그러한 기계에 대한 모든 딜러에게)

당신에게 복사?

(귀하의 문의 사본이 귀하의 이메일 주소로 발송됩니다)

Save input data

(Save input data for further inquiries)

감시 목록에 추가