熱と発電所 HEAT AND POWER PLANT WITH AN ABSORPTION 850 kW

発電機エンジンタービンボイラー / 発電 機

生産者: HEAT AND POWER PLANT WITH AN ABSORPTION

モデル:850 kW

機械のタイプ: 熱と発電所

アイテム番号: 166201280

量: 1

日付: 10.12.2025

場所: Nuremberg, Germany

価格:


Seller-item-No.:5497160

Heat and Power Plant with an Absorption Chiller

An 850 kW combined heat and power plant with an absorption chiller.

The systems ran perfectly until the end and all maintenance was carried out.

No damage is known.

The CHP ran for 51,429 hours of operation.

The absorption chiller has run for 42,350 hours.

The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked:

- complete panelling

- Interfaceschronk

- Oil relubrication pump

Mechanically overhauled and electrically tested

- Oil level monitoring

- Plotter heat exchanger"

- Pressure expansion foll3 (if present)

- Pressure transducer and temperature sensors

- Rubber rails for motor and generator

- Clutch element

- Air filter inserts

- Safety valves and arnot inserts

- Sylomer strips

- Hot water preheating pump and heating element

- Test run with performance and efficiency measurement

- Loosening

- Updated spare parts list and new circuit diagram

Optional:

- Generator (suitable for grid code)

- Exhaust gas heat exchanger

- Gas pressure control line"

- Integration new I pipework, module frame )

- Dia.ne XT3 module controller

- Complete documentation (maintenance log, descriptions, U51258834 techn,

technical diagram, unit drawing )

Not included:

- Seals and connection parts on site

Motor type

JMC 316 GS-N.LC

Electrical output per unit: 835 kW

Thermal output per unit: 986 kW

Frequency: 50 Hz

Voltage: 400 V

Emissions according to valid TA Luft: NOx 500 mg/Nm 3

co 300 mg/Nm 3

The system is operated with natural gas in accordance with the technical instructions TA 1000-0300.

electrical output 850 kW el.

thermal output 945 kW Emission values

NOx < 500 mg/Nm3 (5% 02)

CO < 300 mg/Nm3 (5% 02)

Find more here - /

Contact us at -
フェイスブックでこのマシンをシェアする:

照会

機械販売店?

オプションで送金してください

送信したいお問い合わせ?

あなたにコピーしますか?

Save input data

Heat and Power Plant with an Absorption Chiller

An 850 kW combined heat and power plant with an absorption chiller.

The systems ran perfectly until the end and all maintenance was carried out.

No damage is known.

The CHP ran for 51,429 hours of operation.

The absorption chiller has run for 42,350 hours.

The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked:

- complete panelling

- Interfaceschronk

- Oil relubrication pump

Mechanically overhauled and electrically tested

- Oil level monitoring

- Plotter heat exchanger"

- Pressure expansion foll3 (if present)

- Pressure transducer and temperature sensors

- Rubber rails for motor and generator

- Clutch element

- Air filter inserts

- Safety valves and arnot inserts

- Sylomer strips

- Hot water preheating pump and heating element

- Test run with performance and efficiency measurement

- Loosening

- Updated spare parts list and new circuit diagram

Optional:

- Generator (suitable for grid code)

- Exhaust gas heat exchanger

- Gas pressure control line"

- Integration new I pipework, module frame )

- Dia.ne XT3 module controller

- Complete documentation (maintenance log, descriptions, U51258834 techn,

technical diagram, U51258834 unit drawing )

Not included:

- Seals and connection parts on site

Motor type

JMC 316 GS-N.LC

Electrical output per unit: 835 kW

Thermal output per unit: 986 kW

Frequency: 50 Hz

Voltage: 400 V

Emissions according to valid TA Luft: NOx 500 mg/Nm 3

co 300 mg/Nm 3

The system is operated with natural gas in accordance with the technical instructions TA 1000-0300.

electrical output 850 kW el.

thermal output 945 kW Emission values

NOx < 500 mg/Nm3 (5% 02)

CO < 300 mg/Nm3 (5% 02)

Find more here - /

Contact us at -
seller offer No. resale 5497160
フェイスブックでこのマシンをシェアする:

売り手

logo dealer

UCY Industrial GmbH

Mr Nick Breinfalk
82049 Pullach
Germany

RESALE メンバー から 2024

  • マシンリスト (1394)

照会

機械販売店?

オプションで送金してください

送信したいお問い合わせ?

(そのような機械のためのすべてのディーラーに)

あなたにコピーしますか?

(お問い合わせ内容のコピーがお客様のメールアドレスに送信されます。)

Save input data

(Save input data for further inquiries)