技術データ
· ID 169541257中古機械
- 製造年
- 2016
- 所在地
- Zwolle, Netherlands
Identifikation
メーカーBrueckner
型式Power-Predry HDVB3 CF 20/2
管理番号8931760
Technik
数量1
説明
Manufacturer: Brueckner
Model: Power-Predry HDVB3 CF 20/2
Year of Manufacture: 2016
Application: Thermal treatment of flat textile webs
Working Width: 600 mm min. to 2000 mm max.
Web Speed: 2.5 m/min min. to 50 m/min max.
Drive Side: Right
Operating Side: Right
Number of Drying Fields: 2
Field Lengths
- Infeed conveyor belt: 2.4 m
- Infeed tower: 0.7 m
- Drying fields: 1.6 m (with 1 heating and ventilation section)
- Outfeed tower: 0.7 m
Ventilation and Heating
- Ventilation System: Classic-Flow with adjustable flaps for upper and lower airflow
- Heating Medium: Gas
- Circulation Temperature: 75 to 150 degrees C
- Exhaust Air Volume: max. 6000 m3/h
Electrical and Safety Data
- Operating Voltage: 400 V AC, plus/minus 5%, 50 Hz
- Control Voltage: 230 V AC, 50 Hz / 24 V DC
- Signal Voltage: 24 V DC
- Noise Emission: equivalent continuous sound level at workstation, A-weighted: 80 dB(A)
- Vibration: less than 2.5 m/s2
Included with the Machine
New radial air ventilation unit. Carrier platform. Additional accessories.
Condition
As new. The machine was only ever shown at a trade fair and has never been used in production.
Find more here - .ucymachines/
Contact us at - sales@ucymachines
Model: Power-Predry HDVB3 CF 20/2
Year of Manufacture: 2016
Application: Thermal treatment of flat textile webs
Working Width: 600 mm min. to 2000 mm max.
Web Speed: 2.5 m/min min. to 50 m/min max.
Drive Side: Right
Operating Side: Right
Number of Drying Fields: 2
Field Lengths
- Infeed conveyor belt: 2.4 m
- Infeed tower: 0.7 m
- Drying fields: 1.6 m (with 1 heating and ventilation section)
- Outfeed tower: 0.7 m
Ventilation and Heating
- Ventilation System: Classic-Flow with adjustable flaps for upper and lower airflow
- Heating Medium: Gas
- Circulation Temperature: 75 to 150 degrees C
- Exhaust Air Volume: max. 6000 m3/h
Electrical and Safety Data
- Operating Voltage: 400 V AC, plus/minus 5%, 50 Hz
- Control Voltage: 230 V AC, 50 Hz / 24 V DC
- Signal Voltage: 24 V DC
- Noise Emission: equivalent continuous sound level at workstation, A-weighted: 80 dB(A)
- Vibration: less than 2.5 m/s2
Included with the Machine
New radial air ventilation unit. Carrier platform. Additional accessories.
Condition
As new. The machine was only ever shown at a trade fair and has never been used in production.
Find more here - .ucymachines/
Contact us at - sales@ucymachines