본문으로 건너뛰기

Sera DA Boden - Dissolving station for copper cyanide 디졸브 스테이션

2022ID 166201014

2022ID 166201014

중고인증된 판매자
가격 요청 판매자에게 직접

기술 데이터

· ID 166201014
출처: 판매자 제공 정보

기계

상태
중고
제조 연도
2022
위치
Frankfurt, Germany

Identifikation

제조사Sera
모델DA Boden - Dissolving station for copper cyanide
품목 번호5200501

Technik

수량1

설명

Dissolving station for copper cyanide

The dosing system was designed according to drawing no. A10690 for the preparation of calcium cyanide and copper cyanide solution.

The tank has a volume of approx. 1170 litres and is filled with water via an angle seat valve and with beads/scales/flakes via a feed screw. The dilution water is filled via a solenoid valve and a downstream angle-seat valve for volume adjustment. A spray nozzle in the aeration and deaeration dome prevents vapours from escaping when filling the tank.

The water supply is shut off by a ball valve and the flow rate is adjusted by an angle seat valve. The extraction is switched on or off via the control unit.

The feed screw first conveys the dry material into a two-stage shredder. From there, the dry material enters the container. The quantity of dry material conveyed is regulated via a slide valve on the feed screw. A suction device is mounted on the hopper of the feed screw. The suction device is equipped with a lamellar rubber curtain to prevent direct contact with the dry material. The hopper is fitted with a protective grid. A further suction device is located on the container. The extracted vapours from the two extraction devices are brought together in an absorption vessel via hose lines.

When filling the hopper of the feed screw and loading the container with dry material, it is necessary for both extraction devices to be switched on.

The absorption vessel must be placed and mounted in a suitable position on site using a frame for wall mounting. It must be ensured that the hose lines are supported on site using suitable means if necessary. Kinking of the hose lines must be prevented at all costs to ensure that the vapours are properly conducted into the absorption vessel. The vent connection on the absorption vessel must be connected accordingly on site.

The various fill levels in the container (DRY + EMPTY / MAX-MAX) are detected by fill level limit switches. The level limit switch for DRY RUN + TANK EMPTY is height-adjustable. The fill level in the container can also be checked on the visual fill level indicator. The temperature in the container is displayed via a bimetal thermometer. The container is equipped with an electric agitator for even mixing of the solution. The finished solution is removed or the container emptied via a ball valve at the bottom of the container jacket.

The absorption vessel is emptied into the container via a hose line. It is important to ensure that the washing liquid in the absorption vessel is changed at regular intervals. The dosing system is equipped with a control unit.

The pipework consists of the following components

- Ball valve for end shut-off Filling

- Solenoid valve for filling shut-off

- Angle seat valve for water dosing

- Ball valve for water supply Spray ball

- Solenoid valve for shutting off spray ball

- Angle seat valve for water dosing Spray ball

- Ball valve for removal

- Ball valve for emptying

- Ball valve for emptying when cleaning the supply hopper and the feed screw

It was never installed and never put into operation.

Find more here - .ucymachines/

Contact us at - sales@ucymachines

이 기계 문의하기

문의는 이 기계의 판매자에게 직접 전달됩니다.

필수 항목에는 (별표) 표시가 되어 있습니다.

금액 입력은 선택 사항입니다. '가격 제안 보내기' 창에서 메시지만으로 제안을 보내실 수도 있습니다.
추가 정보(선택 사항)
'입력 정보 30일간 저장' 안내
고객님의 연락처 정보(호칭, 이름, 이메일, 전화, 회사, 도로명, 우편번호, 도시, 국가 및 '딜러' 여부)는 다음 문의 시 양식이 미리 채워지도록 이 브라우저의 쿠키에 30일간 저장됩니다. 체크를 해제하고 문의를 보내시면 저장된 정보가 삭제됩니다.

보내시면 문의가 판매자에게 전달됩니다. 자세한 내용은 다음을 참조하십시오: 개인정보 처리 안내.

유사 기계

문의: Sera DA Boden - Dissolving station for copper cyanide 디졸브 스테이션

ID: 166201014

가격 요청