본문으로 건너뛰기

EXTRAKTLAB e 140 추출기

2021ID 167505891

2021ID 167505891

중고인증된 판매자
가격 요청 판매자에게 직접

기술 데이터

· ID 167505891
출처: 판매자 제공 정보

기계

상태
중고
제조 연도
2021
위치
Poland

Identifikation

제조사EXTRAKTLAB
모델e 140
품목 번호7681657

Technik

수량1

설명

Manufacturer: EXTRAKTLAB

Model: e 140

Condition: Refurbished (2021)

Processes up to 8 kg of input material per hour depending on process conditions.

Extraction vessels: 2 x 20 L

Collection vessels: 3 x 2.5 L

Recycler vessels: 1 x 20 L

CO2 Pump Flow Rates Range (LPM): 1.5 to 2 LPM

Max Operating Pressure (psi): 5000 psi, 344.74 bar

Maximum Process Temperature: 90°C

Skid Operating Temperature (C°): 5 to 40°C (15 to 30°C optimal)

CO2 Solvent Inlet Lines: 1

Eluent Inlet Lines: up to 2

User Interface: Touch Screen HMI panel with barcode scanner, maintenance tracking, recipe storage (parameter). 21 CFR Part 11 compliant software.

Biomass Loading and Unloading: 10 micron flexible no channel bags

Operating Humidity: 20 to 80%

Compliance – UL 508A electrical panel Electrical – 50 Hz 208V-240V, 3 phase,

Footprint:- 24ft. Dimensions – 99″ x 34″ x 72″ (LxWxH)

Construction: 316 stainless steel, Ferrule compression fittingsthroughout

Sound Pressure – 50 dB

Wetted Materials – FDA approved structural stainless steel.

Chemical Compatibility: CO2, Organic Solvents, Acids and Bases, plant extracts

Flow Control: Manual, Automatic

Flowe Meter: PID Controlled Algorithm, rules based on process parameters

CE and food grade GMP certified

Independently PE Stamped according to ASME DIV II VII-2PED compliant, CE marked, notified body, Lloyds Register, CRN number available

Safety Specifications:

Rupture Discs: Zook burst discs, calibrated, ASME VIII Div IIcompliant, Max Pressure is 5300 psi, Certificate Attached to Disc

Temperature Switch: Preheater, Post heater MAX TEMP 140°C,Certificate Available Collector, Extractors MAX TEMP 100°C, Certificate Available

E-stop Switch: Switch disengages main contactor, not dependenton PLC

CO2 Gas Detector: Built in alarm, turns off pump and closes valves at9000

Interlocks: Marked with safety warnings

Pressure Transducers: Post pump, Extractor, Collector 1.3; Turns off pumpwhen overpressure (>5100 psi) condition is detected

Isolation Valves: Manual, bypass valves.

Technical documentation: available.

Find more here - .ucymachines/

Contact us at - sales@ucymachines

이 기계 문의하기

문의는 이 기계의 판매자에게 직접 전달됩니다.

필수 항목에는 (별표) 표시가 되어 있습니다.

금액 입력은 선택 사항입니다. '가격 제안 보내기' 창에서 메시지만으로 제안을 보내실 수도 있습니다.
추가 정보(선택 사항)
'입력 정보 30일간 저장' 안내
고객님의 연락처 정보(호칭, 이름, 이메일, 전화, 회사, 도로명, 우편번호, 도시, 국가 및 '딜러' 여부)는 다음 문의 시 양식이 미리 채워지도록 이 브라우저의 쿠키에 30일간 저장됩니다. 체크를 해제하고 문의를 보내시면 저장된 정보가 삭제됩니다.

보내시면 문의가 판매자에게 전달됩니다. 자세한 내용은 다음을 참조하십시오: 개인정보 처리 안내.

유사 기계

문의: EXTRAKTLAB e 140 추출기

ID: 167505891

가격 요청