Turboden 10HR Split ORC ORC
中古

1 / 8
技術データ
· ID 170511765中古機械
- 税抜価格
- 280.000 € netto
- 状態
- 中古
- 製造年
- 2012
- 稼働時間
- 25.000 h
- 所在地
- 89250 Senden
Identifikation
メーカーTurboden
型式10HR Split ORC
Technik
数量1
説明
Turboden 10HR Split ORC – 707 kW electric gross power
For sale is a Turboden ORC module of the type 10HR Split, manufactured in 2012. The system was professionally decommissioned and preserved by Turboden.
The ORC module converts heat from a thermal oil circuit into electricity and can additionally release heat via a hot water circuit. The documented load cases show a gross electrical output of 657 to 774 kW. In the contractual design case, it amounts to 707 kW.
Technical Key Data
- Manufacturer / Type: Turboden 10HR Split ORC
- Year built: 2012
- Documented operating hours: approx. 25,000 hours
- Electrical power under load: 707 kW gross
- Thermal oil heat output in the design scenario: 4,593 kW
- Thermal oil temperatures: 315 °C flow / 160 °C return flow
- Hot water heat output in the design scenario: 3,869 kW
- Hot water temperatures: 58 °C inlet / 89 °C outlet
- Documented efficiencies: approx. 13.8–15.4% gross, depending on load case
The offered module includes the main ORC components and associated equipment listed in the documents, including turbine, generator, heat exchanger, pump, control cabinets, as well as piping and fittings.
The stated performance values refer to the documented load cases. Suitability, actual system condition, and required integration must be assessed by the buyer based on their own operating conditions and a technical inspection. Inspection and testing by agreement.
For sale is a Turboden ORC module of the type 10HR Split, manufactured in 2012. The system was professionally decommissioned and preserved by Turboden.
The ORC module converts heat from a thermal oil circuit into electricity and can additionally release heat via a hot water circuit. The documented load cases show a gross electrical output of 657 to 774 kW. In the contractual design case, it amounts to 707 kW.
Technical Key Data
- Manufacturer / Type: Turboden 10HR Split ORC
- Year built: 2012
- Documented operating hours: approx. 25,000 hours
- Electrical power under load: 707 kW gross
- Thermal oil heat output in the design scenario: 4,593 kW
- Thermal oil temperatures: 315 °C flow / 160 °C return flow
- Hot water heat output in the design scenario: 3,869 kW
- Hot water temperatures: 58 °C inlet / 89 °C outlet
- Documented efficiencies: approx. 13.8–15.4% gross, depending on load case
The offered module includes the main ORC components and associated equipment listed in the documents, including turbine, generator, heat exchanger, pump, control cabinets, as well as piping and fittings.
The stated performance values refer to the documented load cases. Suitability, actual system condition, and required integration must be assessed by the buyer based on their own operating conditions and a technical inspection. Inspection and testing by agreement.
この機械について問い合わせる
お問い合わせはこの機械の出品者に直接届きます。