Four IVA MKG 2s 70/95/110

technologie des processus / machines et installations pour l'ingénierie des processus

Fabricant: IVA

Modèle:MKG 2s 70/95/110

Type de machine: Four

Numéro de l'article: 166929885

Quantité: 1

Date: 19.01.2026

Emplacement: Dresden, Germany

Prix:


Seller-item-No.:7297705

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner U6158834 and Gas Details:

- Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
Partager cette machine sur Facebook:

Enquête

Marchand de machines?

S'il vous plaît remettre éventuellement

Envoyer la demande?

Copie pour vous?

Save input data

Quenching of the Batch

The batch is quenched by immersion in a quenching medium (oil).

---------------------------------------------------------------

Dimensions and Weights

Overall Dimensions (including control system):

- Width: approx. 3400 mm
- Height: approx. 5600 mm
- of which recessed in the pit: 650 mm
- Length: approx. 5500 mm
- Minimum required hall height: 7000 mm
- Working height above floor level: 1200 mm
---------------------------------------------------------------

Base Grate Dimensions:

- Width: 705 mm
- Height: 50 mm
- Length: 1100 mm
---------------------------------------------------------------

Usable Batch Space (including base grate):

- Width: 700 mm
- Height: 950 mm
- Length: 1100 mm
- Grate loading height: 900 mm
- Gross batch weight (incl. base grate): 1000 kg
---------------------------------------------------------------

Oil Bath:

- Oil capacity: approx. 6000 liters
---------------------------------------------------------------

Weight:

- Empty furnace weight: approx. 15,000 kg
- Operating weight (incl. oil and batch): approx. 23,000 kg

Electrical and Gas Requirements:

- Voltage:
- 400 V, 50 Hz
- 230 V, 50 Hz
- 24 V DC
- Power Consumption:
- Approx. 85 kW
- Pre-pressure (Customer-supplied) for Natural Gas:
- 70-200 mbar
- Consumption per Ignition Burner (Natural Gas):
- Max. 700 l/h
- Connection Specifications for Safety Burners (Flame Curtains and Ignition Monitoring):
- Natural Gas: 8.0 Nm³/h
- Electric Heating/Cooling: 1000 °C / Heating cartridges / Inconel radiant tube 601
---------------------------------------------------------------

Burner U6158834 and Gas Details:

- U6158834 Manufacturer:
- [Brand Name]
- Number of Radiant Tubes: 6
- Maximum Heating Power per Tube: 30 kW
- Total Heating Power: 180 kW
- Natural Gas Consumption: Max. 18 m³/h
---------------------------------------------------------------

Protective or Reactive Gases:

- Pressure Equalization - Pre-chamber Nitrogen:
- Each cycle (4-6 bar storage, customer-supplied): Safety Gas (Purge Gas) Nitrogen (3 bar, customer-supplied)
- Carbonization Gas (Nitrogen/Methanol):
- Nitrogen (3 bar, customer-supplied): approx. 6 Nm³/h
- Methanol (1.2 bar, customer-supplied): approx. 6 NI/h
- Carbonization Gas (3 bar, customer-supplied): approx. 12 Nm³/h

Find more here - /

Contact us at -
seller offer No. resale 7297705
Partager cette machine sur Facebook:

Vendeur

logo dealer

UCY Industrial GmbH

Monsieur Nick Breinfalk
82049 Pullach
Germany

RESALE membre depuis que 2024

  • liste des machines (1377)

Enquête

Marchand de machines?

S'il vous plaît remettre éventuellement

Envoyer la demande?

(à tous les concessionnaires pour une telle machine)

Copie pour vous?

(copie de votre demande vous sera envoyée à votre adresse e-mail)

Save input data

(Save input data for further inquiries)