Model
(Manufacturer: JÜRGEN LÖHRKE GMBH)
used
Plant for the pressureless production of an aqueous chlorine dioxide solution. The two starting materials will be successively conveyed with peristaltic pumps in a reaction vessel. There, the levels are over a level probe is scanned so that a correct mixing ratio of 1: 1 is guaranteed. In addition, the running time of the peristaltic pumps is monitored by the software. After the reaction time, the finished chlorine dioxide solution is rinsed with water in the reservoir tank and metered from there by means of diaphragm metering pump and metering valve at the point of use., Additional title: Water treatment - chlorination, Capacity: 18 g/h ClO2, Dosage volume: 9 l/h against 7 bar, Operating pressure: 6 bar, Operating temperature: 30 °C, Voltage: 120-240 V, Frequency: 50/60 Hz, Length: 290 mm, Width: 620 mm, Height: 820 mm, Operation / Control: Siemens S7-300 with color-touchpanel, Feature ...