We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
new
TO WHOM IT MAY CONCERN WE VE NEW UNUSED GENUINE SPARE PARTS OF MAN NR 34S AT OUR STOCK. NEW BEARING BUSH 1151768-0353 517003 1PCS NEW LOCATING BEARING 1151768-0580 517002 1PCS NEW NOOZLK E RING IMO 3318 129.88cm3 1PCS NEW BEARING ASSY 5891812 30021F 8PCS ALL PARTS EX STOCK LOACTED AT IZMIR TURKEY. IF YOU VE ANY FURTHER QUESTIONS PLS DO NOT HESITATE TO CONTACT WITH US .
new
TO WHOM IT MAY CONCERN; WE VE NEW UNUSED GENUINE SPARE PARTS OF MAN TURBO NR 34S AT OUR STOCK. NEW SET OF SPARE PARTS 1159500-0138 2PCS NEW SET OF SPARE PARTS 1191468 1PCS NEW BEARING BUSH 1191468 7PCS NEW BEARING BUSH 1151768-0442 1PCS NEW NOOZLE RING IMO 2475 128.05cm3 2PCS NEW LABYRINTH RING 1191468 2PCS NEW LOCATING BEARING 1191468 2PCS NEW LOCATING BEARING 517002 1PCS ALL PARTS EX STOCK LOCATED AT IZMIR TURKEY. IF YOU VE ANY QUESTIONS . PLS DO NOT HESITATE TO CONTACT WITH US .
new
Description: Type : ÖLtransformator Version : Hermetic Make : CG POWER SYSTEMS Belgium NV B7ssq0vkzj Year of construction : 2012 Condition : New with 1 year warranty Rated power : 3500 KVA Medium voltage : 33 KV +- 2 x 5% Low voltage : 400 V Switching group : Dyn 5 Frequency : 50 Hz Cooling type : KNAN Total weight : 7750 Kg Oil weight : 1720 kg Synth. ESTER Length : 2400 mm Width : 900 mm Height : 2250 mm + 160mm cable flag Other sizes and voltages also available from 100 KVA to 3500 kva . All transformers are tested and ready for use and immediately available from our warehouse in 59557 LIPPSTADT . Nationwide delivery . For further questions available Mon to Sat. 8 a.m. to 10 p.m.
new
Steam turbine Siemens SST400 Year: 2011 Disassembled and put in a storage. Very low working hours. Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Turbo gear unit Flender-Graffenstaden TX80/3 Transformer Siemens S10-40000/110 Condenser Full set of manual books No boilers, no voltage control cabinet (7) Steam turbine Siemens SST-400 Year: 2011 Never used and never installed. Still in original wooden crates. Packing lists. 7 sets available Power:30mW Voltage:10.5kV/50Hz Fuel: Biomass Generator: SGen5-100A-4P Control system Accessories Full set of manual books No boilers Price: on request
used
Kawasaki Model TD80A-1 7.2 MW Type TD80A Rated Output 7216 kW Voltage 11000 V Frequency 50 HZ Current 446 A Phase 3 Gas Turbine M7A-03D Generator NTAKL-DC YOM 2011 low hours 7836
new
215 MW Toshiba Inlet Steam Turbine & Generator (Unused and well maintained) New in 2008, this Power Plant has never been used and is available for immediate inspection and delivery. Never having been used, the Plant has no wear whatsoever. The Steam Turbine: Extraction & condensing, Inlet pressure: 104 bar, Output: 215MW Extractions: MP2: 22 bar, MPI: 10 bar, LP: 4.5 bar, Feed Water: 0.4 bar Minimum load: • No extractions, Only bleeds, Steam flow: 45 kg/s Maximum load: Steam flow: 270 kg/s The turbine is a Single Flow Extraction Condensing type. Steam initially enters the steam inlet flange near the end of the high pressure section and flows through the turbine stages toward the generator end of the unit. After passing through the turbine stages, the steam is exhausted to condenser. The exhaust hood is keyed to the foundation plates at a point near its ce ...
750 MW each, UNUSED Gas Based Complete Combined Cycle Power Plants 2 units available Technical Specifications: The Project Details: 1. EACH module has two Gas turbines GE 9FA.03 (DLN2+) and one Steam turbine GE D11. Each GT exhaust is directed to the triple pressure unfired, natural circulation horizontal, type CMI USA HRSG. This configuration helps turndown operation of station up to 45%. 2. The Station is based on robust design of GE Gas Turbine with high efficiency DLN2+ Dry low Nox system, each GT is site rated for an output of 235 MW and the triple pressure reheat GE D11 Steam Turbine with downstream Exhaust, is site rated at 266 MW. The HRSG is a Triple pressure, Natural circulation, Horizontal design type with Deaerator atop the LP drum. Thus Net Combined cycle efficiency at Site condition is approx 57% on LHV basis. The inherent design of the gas turbine reduced the N ...
used
GE LM2500+ For Sale (31.3 MW, 50 Hz): GE LM2500+ natural gas-fired and associated Aalborg HRSG. The GE LM2500+ has a nominal output of 30 MW. The OCGT originally produced steam for local combined heat and power (CHP”) demand, which no longer exists. Due to this, the HRSG is kept in dry preservation and the OCGT operates using the bypass stack, providing black start and short-term operating reserve capability. Open cycle GE LM2500+ GT driving a 36 MVA generator, which is a totally enclosed air-cooled (TEAC”) design rated at 11 kV. The boiler on this unit is currently in dry preservation. The LM2500+, a design based on the very successful heritage of the LM2500 gas turbine, rolled off the production line in December 1996. The LM2500+ was originally rated at 27.6 MW, for a nominal 37.5 percent thermal efficiency at ISO, no losses and 50 Hz. Since that time, its rating has continually ...
used
16 x 3.2MW 60Hz KAWASAKI Gas Turbine Power Plant Main specifications - Gas Turbine Model: M1T-23 x 16 sets - Maker: KAWASAKI - Power Output: 3,200kWe - Frequency & Voltage: 60Hz & 6600V - Year of Production: 2008 - Running Hours: about 60 hours - Fuel Oil: Natural Gas - Plant Auxiliary Equipment: 1 set This gas turbine plant has 16 x 3.3MW gas turbines with the optimal layout of 4 x 4 blocks and was initially installed as an emergency power supply in preparation for major disasters or large-scale power outages in the area. Fortunately, as there has been no serious emergency, this plant has had almost no operation, and the total running hours does not exceed 60 hours for each unit until today. However, as the plant has been regularly checked and well maintained, now the gas turbines units are in the best condition. This power plant is scheduled to be shut down i ...
used
5.5MW 60Hz KAWASAKI PUC60 ECOPLUS Gas Turbine Power Plant This is an eco-plus gas turbine power plant that has been being operated successfully for over 160,000 hours since it was manufactured in 2002 and installed. This plant has been regularly inspected and very well maintained according to the maintenance manual by the operating company. Now, the plant is scheduled to go for sale after stopping its commercial operation around June 2023. Main specification: - Gas Turbine Model: KAWASAKI PUC60 ECOPLUS - Maker: KAWASAKI - Power Output: 5,570kW - Frequency & Voltage: 60Hz & 3300V - Year of production: 2002 - Running Hours: 163,858 hours - Fuel Oil: Natural Gas - Plant Auxiliary Equipment: 1 set
1. General specification -Maker MES (Mitsui Engineering & Shipbuilding Co., Ltd.) Japan -Mfg. data 2014 -Running time Zero hoursP 2. Steam turbine specification -Maker MES (Mitsui Engineering & Shipbuilding Co., Ltd.) Japan -Turbine type CD30.46 -Steam in let pressure 70barG -Steam inlet temperature 490℃ -No.1 Extraction steam P & T 31.5barG & 388.5℃ -No.2 Extraction steam P & T 5.5barG & 223.3℃ -Nor. Exhaust pressure 0.11barA -Turbine speed 3,600 rpm -Rated output 97,500 kw -Weight 132 ton -Number of stages 16 -Number of 1 stage nozzle arcs 4 -Steam inlet flange ASME1500#RJ12” x 2 -No.1 extraction steam flange ASME 600#RF 16” -No.2 extraction steam flange ASME 150#RF 32” -Steam exhaust flange ø3,600(inner dia.) 3. Synchronous generator -Standard IE60034-1(2010), IEC60034-3(2007) -Location Indoor -Cooling system Totally enclosed type with top-moun ...
used
A 3552 KW Solar Centaur 50 gas turbine for sale. Brand: CAT Solar Centaur 50 Type: EH5701-59-G Electr. Power: 3652 KW Generator: ABB Stromberg Drives Type: HSG 710K4 Electr. Line: 5000 KVA Voltage: 10500 V Year of construction: 1991 Weight: 21.000 Kg FCA freely charged in Koblenz
used
Manufacturer: Trane Type: CLCE 1810 Manufacturing year: 2005 Overall dimensions: 3330 x 1900 x 2000 mm Suction side dimensions: 900 x 900 mm Fan: Manufacturer: Nicotra Type: VRE RDH 710 K1 Maximal drive power: 37 kW Maximal rev: 1700 1/min Electro motor: Manufacturer: Tee Electric motors Type: QU 200 L4C-40 H Electric power: 30 kW
used
3 MW Siemens Steam Turbine SST-110 TWIN AFA 46 K Year: 2010 Hours: 5,200 Capacity: 3,224 kW Volts: 400 HZ: 50 Condition: Very Good Scope of Supply: Complete Turbine Power Station Turbine and alternator Control Panel Condensor Cooling Towers Spilling Unit Switchgear Synchronisation panel Transformer Piping / wiring / pumps Boiler not included Inspected in Very Good Condition . Dismantled and loaded to your transport .
used
Make and model: Turboden ORC Year: 2016 Electrical capacity: Ran at 700kW (Normal rating: 643 kW) V: 400 HZ:50 Now available for sale. Price: 400,000 GBP
used
Turbogas Turbine GE5/1 5MW Natural gas for sale. Complete turbogas turbine plant with electric generator, recovery boiler and exchangers, dry cooler, diverter. Total Hours: 36,000 8,000 hours from the last overhaul. THERMAL POWER 9,0 MWt Saturated steam production 13,000 kg/h at 10BARg Voltage 11000 V Frequency 50 hZ Also available: - GE5/1 used turbine in nitrogen storage with 72,000 hours + 8,000 Hours after the last overhaul + one used generator. Price: €300,000 - NEW GE5 Turbine Spare Parts (value 1 million) Price: €400,000
used
The power plant, based on a 5 MW gas turbine CENTRAX 501 KB7 is complete with all needed equipment, allowing a steam output of 20 tons per hour at 20 bar. From ZERO hours until the last working day all maintenance was performed by Centrax under full maintenance contract.
2 x SOLAR SATURN 20 for sale. Package is complete, still installed and now FOR SALE 1.1mw each... Total 2.2 mw serious inquires and end user buyers only please email for further information. Basic details will be uploaded soon here on this page.
used
MBARBECOL turbine flap PN-5478 MAN 28/32 engine Just the turbine hull.
used
HHI-BBC Turbine Housing RPM - 17400 Only the turbine hull.
used
Steam turbine MAN MARC 4 - 17.650 kW Turbine set includes: steam turbine, generator, generator cooler and an oil skid. Offer directly from the owner. Technical specifications: Designation Unit Normal Max Manufacturer: MAN Turbo AG Type: MARC 4 - B02 Power kW: 17.650 Rated speed 1/min: 8120 Quick closing speed 1/min: 8650 Main steam pressure bar: 74 Main steam temperature: C 447 Fresh steam quantity t/h: 140 Tap steam pressure 1 bar: 31.8 m Tap Steam Temp.1 C 336 Tap steam pressure 2 bar: 25.2 Tap steam temp.2 C 307 Outlet pressure bar 7,5 abs/6,5 guage Evaporation temperature: C 182 C 3 Synchron Generator (incl. cooler) Producer: Ellin Motoren Model: HTM-110 Z04 Building Year: 2007 22800 kVA 10500 V+- 5% 50 HZ Directly from the owner. Please contact us for more details.
used
Turbine Nadrowski Superheated steam turbine Brand turbine factory Nadrowski Type B 5 S4+GIV/V Year of construction: 1989 for generating electricity from superheated steam Maximum steam temperature 400°C Working pressure 4-31 bar Maximum power 632 kW with Synchronous Generator AVK DKBN 100K/800-4 Power 813kVA, current 1173 A regularly serviced External dimensions approx. L 4 m x W 1.50 m x H 1.50 m
used
GE LM 2500 gas turbines 2 pcs available Power:24.000 Hp each Average working hours 1700 hours
new
Hydroelectric power station - Power 790 kW composed of: 1 Turbine Pelton / Effective gradient 223m / Water volume 400 l/s / 1 piece generator 1 shut-off device 1 hydraulic power unit 1 piece transformer
used
Taurus 60 Turbine Generator Set Solar Taurus 60 T7301 Gas Turbine Engine Runnig hour 1165 hour after last Overhaul Output Power 5200 Kw Gearbox Solar Gear Unit 1165 hour after last Overhaul Type: Epicyclic Leroy Somer Generator 50 Hz
used
One used AEG Kanis G 20 back pressure steam turbine from 1985 in good running condition. The steam inlet pressure of 14 bar can be increased up to 20 bar. Alternators with other voltages are also available on request. For Sale type: AEG-Kanis G20 el. power: 2046 KW generator end: AEG 2650 KVA, 5250 Volts, 50 Hz, cos phi 0,8 steam consumption: 40 to/h at full load steam inlet pressure: 14 bar (up to 20 bar possible) back pressure: 4,5 bar inlet steam temperature: 320 °C gear ratio: 8,04 manufactured: 1985 mesurements: 8,30 L 3,00 H 4,2 W price on request: Here you can download all the turbine pictures (30 MB): abc.stromerzeuger-discount.de/AEG-Kanis_G20_back_pressure_2046_kw_stea m_turbine_14_bar/all_pictures.zip Here you can download the scope o ...
used
1300 KW KK&K CFR3 G5A tandem condensing steam turbine 40 bar inlet pressure from 1997 with 50.000 running hours in very good working condition for sale. Scope of supply: controlpannel, turbine with generator, documents. turbine: KK&K type: CFR3 G5A el. power: 1300 KW steam inlet pressure: 40 bar manufactured: 1997 generator: AEM type: SE 500 M4 powerrating: 1830 KVA volts: 400 volts Hz: 50 Hz price on request: Stromerzeuger-Discount.com Kürtener Straße 13 D-51465 Bergisch Gladbach Mobile: 00491635263546 Telefon: 0049 2202 2492256 Fax: 0049 2202 2492257 Email: info@stromerzeuger-discount.de
used
GE MS5000P Nominal Pot 20.000kw each , 1600 work hours
used
Turbine Turbine operating hours: 30,000h Backpressure turbine Manufacturer: Kkk First start-up: 2002 Type: CFR5 G6a Power max: 2500 kW Operating efficiency: 2200 kW, Number of revolutions: 23000 rpm, Live steam pressure: 65 bar, Live steam pressure temperature: 480 C, Evaporation pressure: 1-17 bar, Investments in 2002 , Entire steam transformation station renewed from 63 bar to 2.5 bar in 2002, El. Generator Fa. Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA, renewed, complete measurement, control and control of the turbine renewed, steam turbine renewed with energy production General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic corder and ash removal system renewed, water treatment plant renewed, complete instrumentation renewed, flue gas cleaning plant Lurgie renewed from 1991 - 2001 Mistakes excepted!
used
Combined Cycle Gas Turbine Power Plant 75 MW/50 Hz – Zero Hours This equipment was delivered in 2017 by an EPC contractor who selected Rolls-Royce and Siemens as main equipment suppliers. This was a greenfield project and therefore delivery contained all equipment needed for 75 MW power plant operation, like fuel gas treatment plant, water treatment plant and complete switchyard with step-up transformers Manufacturing year: 2017 Gas turbine: Rolls-Royce Trent 60, Dry Low Nox Steam turbine: Siemens SST-300 Step up tranfomers: 2 pc Alstrom 11kV to 154 kW Complete switchyard: Siemens 154 kV Nominal output 100%: 60 MW + 15 MW Max efficiency: Single cycle 42 %, combi cycle 54% Heat recovery steam boiler: 30 bar / 300 C Water treatment: Sand and active coal filters + RO Documentation: Complete original in English Delivery: Complete plant equipment from water and gas ...