Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, electronic injectors, buffer tank 678 ltr. and built-in P3 circulating pump: Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,48 Max. current (A) 119.28 Starting current circuit (A) 235,01 Protection Class: IP5 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, electronic injectors, buffer tank 678 ltr. and built-in P3 circulating pump: Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,48 Max. current (A) 119.28 Starting current circuit (A) 235,01 Protection Class: IP5 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, buffer tank 678 ltr. and built-in P3 circulating pump. Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,5 Max. current (A) 119.3 Starting current circuit (A) 235 Protection Class: IP54 Dimensions: Length (m ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 M.T.A. S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crankpan heating, phase monitoring, buffer tank 678 ltr. and built-in P3 circulating pump. Cooling capacity kW 136 Cold water temp. Exit/ Entry (°C): 7 / 12 Volumetric flow rate (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70,5 Max. current (A) 119.3 Starting current circuit (A) 235 Protection Class: IP54 Dimensions: Length (m ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 201P3 MTA S.p.A. TAEevo Tech 201 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 350 ltr. And built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 44.2 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 7.53 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 23.69 Max. current (A) 39,83 Starting c ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 351P3-20 MTA S.p.A. TAEevo Tech 351P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, electronic expansion valves, phase monitoring, buffer tank 350 ltr., built-in P3 circulation pump and speed-controlled fans. Cooling capacity kW 66.9 Cold water temp. Exit/Entry (°C): 7 / 12 Medium: Water Volume flow (m³/h) 11.4 Available pump pressure (bar) 3.02 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 37.48 Max. current (A) 64,44 Starting curre ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 351P3-20 MTA S.p.A. TAEevo Tech 351P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, electronic expansion valves, phase monitoring, buffer tank 350 ltr., built-in P3 circulation pump and speed-controlled fans. Cooling capacity kW 66.9 Cold water temp. Exit/Entry (°C): 7 / 12 Medium: Water Volume flow (m³/h) 11.4 Available pump pressure (bar) 3.02 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 37.48 Max. current (A) 64,44 Starting curre ...
Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...
Process air cooler / chiller / chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr. and built-in P3 circulation pump Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Flow rate (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 99 Max. ...
Process Air Cooler / Chiller / Chiller Air Cooled, Type: TAEevo Tech 020 P3 MTA S.p.A. TAEevo Tech 020 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 5,68 [19380 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 0.951 Available pump pressure (bar) 2.9 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 4.12 Max. current (A) 7.21 ...